X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22125

Well Details

Well ID: 34-035-22125
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: GENESIS RESOURCES LLC
Well Pad ID:
Farm/Lease Name: OYLER
License Status: Producing
License Date: 2009-07-28
Spud Date: 2009-09-17
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2009-09-28
Well Total Depth: 3901.00 ft
Configuration: Directional
Latitude: 41.320000
Longitude: -81.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-07-28 Proposed Formations:OHIO SHALE TO CLINTON, Issued Date:7/28/2009, Expired Date:7/28/2010 6:00:00 AM, Drilling unit acres:23.8524, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-09-28
Correction to Well 2009-11-06 CORRECTION TO TARGET INFORMATION AS A RESULT OF "AS DRILLED SURVEY"; NEW FOOTAGE= 1782'SL & 3018'EL OF SEC. 22; X= 2,220,898; Y= 605,642; ELEV= 1180'. UNIT SIZE INCREASED TO 24.4484 ACRES.
Completion Report Received 2010-02-02
Correction to Well 2010-02-05 CORRECTION TO TARGET INFORMATION: NEW FOOTAGE--1782'SL & 3018'EL OF SEC. 22/NEW X= 2,220,898/NEW Y= 605,642/NEW ELEVATION: 1180' (AS DRILLED SURVEY). INCREASE IN UNIT SIZE TO 25.6056 ACRES.
Construction Permit Expires 2010-07-28
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-04-20 3614 3654 87
3614 3654 87
3614 3654 87

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 200 Mscf 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER OIL COMPANY 0.00 233.00 81
2010 CUTTER OIL COMPANY 5679.00 2779.00 365
2011 CUTTER OIL COMPANY 5526.00 2351.00 365
2012 CUTTER OIL COMPANY 4628.00 692.00 366
2013 CUTTER OIL COMPANY 2495.00 215.00 365
2014 CUTTER OIL COMPANY 5065.00 570.00 365
2015 CUTTER OIL COMPANY 2296.00 361.00 365
2016 CUTTER OIL COMPANY 146.00 0.00 365
2017 CUTTER OIL COMPANY 0.00 0.00 60

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER OIL COMPANY Brine 3589 81
2010 CUTTER OIL COMPANY Brine 10346 365
2011 CUTTER OIL COMPANY Brine 8289 365
2012 CUTTER OIL COMPANY Brine 7886 366
2013 CUTTER OIL COMPANY Brine 1634 365
2014 CUTTER OIL COMPANY Brine 3034 365
2015 CUTTER OIL COMPANY Brine 1961 365
2016 CUTTER OIL COMPANY Brine 143 365
2017 CUTTER OIL COMPANY Brine 287 60

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1211097243 2009-11-5 0:00: DD No Violations
-1380580502 2009-10-21 0:00 DD No Violations
-1575730662 2010-1-11 0:00: PW No Violations
-1614847687 2012-11-27 0:00 UL No Violations
-1667785120 2009-9-18 0:00: DD No Violations
-1775293554 2009-9-18 0:00: DD No Violations
-1967393560 2014-7-14 0:00: UP No Violations
-2017449213 2009-9-21 0:00: DD No Violations
-293225676 2020-2-6 0:00:0 PW No Violations
-835481734 2012-7-2 0:00:0 UP No Violations 1.00
0205698749 2018-02-08 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previous inspection in which I had noted the following: Electrical boxes were not locked. Production tank lids were not latched down as required. The dike drain riser was not secure and leaking. There was a significant gap between the bottom of the fence enclosure and the ground surface at the well enclosure and battery rendering the enclosures unsecure. Signage was lacking complete information. There was a notable amount of grease leaking down from the Pitman bearing on the pump jack which needs addressed. The 8.625-inch casing was not exposed for monitoring as required. In addition, the following safety issues were noted. Load lines were not locked. Brine was actively leaking from the 2-inch flange at the brine tank. The owner had been notified of the deficiencies. At the time of this inspection, the listed violations and deficiencies had been remedied. Tank lids were closed and secure. Load-lines were locked. Signage had been updated. The surface casing nipple was exposed with pressure gauge. The leaking grease had been remediated and the brine leak repaired.
0403163419 2009-09-23 Production Wells No Violations no violation of HB278.
0621749036 2018-02-08 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, fittings and connections at the wellhead pump jack and battery were secure and free from leakage or problems. The individual enclosures were locked and secure. Production reports were current. Proper bonding and insurance was in place. The well was not in active production,. The owner has indicated that a sale of this unit is pending.
0835481734 2012-07-02 UrbanProduction Wells No Violations My inspection today found no violations. Well is in compliance.
1202556856 2015-02-19 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activities. The wellhead and battery are located in a wooded area on the south side of Tollis Parkway. The wellhead pump jack and battery are in separate board-on-board enclosures which are locked. Signage is present. Secondary containment at the wellhead and the battery are present and well maintained. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. The battery is shared with the #2-2126 and the #2-2003 units. The load-outs are plugged. Gates are locked.
1211097243 2009-11-05 Drill / Deepen / Reopen No Violations area around well graded and hyro seeded
1380580502 2009-10-21 Drill / Deepen / Reopen No Violations checking area graded and seeded.
1431661434 2015-05-07 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. The well is located in a clearing within a primarily wooded area. The entry to the well is gated with a cable-style gate which is locked. . The access road is gravel-paved and accesses each of three wellheads (Oyler 1, 2D, and 3D). At the time of this inspection, there are no wash-outs or erosional deficits. The wellhead is comprised of a pump jack unit in a board-on-board enclosure which is locked. The shared tank battery is comprised of a total of 6 140-barrel steel production tanks, 3 50-barrel poly brine tanks, and 3 mechanical separators. The entry door is secure and locked. At the time of this inspection, the following maintenance issues were noted: Electrical boxes are not locked. Production tank lids are not latched down as required. The dike drain riser is not secure and leaking which requires remedy. There is a significant gap between the bottom of the fence enclosure and the ground surface at the well enclosure and battery rendering the enclosures unsecure. Signage is present but lacking complete information. There is notable amount of grease leaking down from the Pitman bearing on the pump jack which needs addressed. An empty 55-gallon drum and chemical pump should be removed if not used. The 8.625-inch casing is not exposed for monitoring as required. In addition, the following safety issues were noted. Load lines are not locked. Brine is actively leaking from the 2-inch flange at the brine tank. These safety issues must be remedied by 06/19/2015. Please contact Inspector Stephen Tompkins with questions regarding these isues.
1575730662 2010-01-11 Production Wells No Violations ground snow covered to check restoration!
1614847687 2012-11-27 UrbanPreliminary Restoration No Violations On my inspection of this well today I was accompanied by Steve Tompkins, Lake County Inspector, DOGRM. Our inspection was for Urban Preliminary Restoration of this well site. Access Road is crushed, packed limestone and brick too well head and tank battery area. Access road gate is locked and secure. The wellhead is clean and neat with no signs of problems or issues. Well head is secured within a board on board fence which is locked and secure. The tank battery is located within a board on board fence which is locked and secure, and is a shared tank battery with the Oyler D 1 unit P# 2-2003 and the Oyler 3 D unit P# 2-2126. Each well has its own separate tank unit system. System consists of two 140 BBL storage tanks and one 70 BBL brine tank. Storage tank lids are closed and secure. Tanks are properly vented with a tank vents and a charcoal filter unit. There is one vertical and one horizontal separator unit for the well as well as pick up lines which are secured with locks and bull plugs. The well is equipped with metering runs. The well is in compliance with 1501:9-9-05 and preliminary restoration is passed.
1667785120 2009-09-18 Drill / Deepen / Reopen No Violations rig moving onto site digging pits no violation.
1743714138 2010-08-24 Preliminary Restoration No Violations checked well for complaint on Royalwood rd.

No violation

1775293554 2009-09-18 Drill / Deepen / Reopen No Violations cementing conductor casing in.
1967393560 2014-07-14 UrbanProduction Wells No Violations I inspected this producing unit as part of customary and routine inspection activities. The unit is producing and production reports are current. ID placards are present and have current and accurate contact information. The tank battery secondary containment dike is is good condittion. The natural surface drainage from the area of the wellhead and tank battery is to the southeast and I did not observe any signs of gully formation, wash-outs, or other impacts associated with the unit. Enclosure gates are locked. I did not observe any signs of leakage, spills, or other problem conditions.
2017449213 2009-09-21 Drill / Deepen / Reopen No Violations cementing surface casing in .
205698749 2018-2-8 0:00:0 UP No Violations 1.00
403163419 2009-9-23 0:00: PW No Violations
621749036 2018-2-8 0:00:0 UP No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1431661434 US-OH-112622 2016-07-26 9-05E3 LOCKS
1431661434 US-OH-112623 2016-07-26 9-1-07 Well operation causing pollution and contamination

For data sources see[9]

References