34-035-22122

Well Details

Well ID: 34-035-22122
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: EOS ENERGY LLC
Well Pad ID:
Farm/Lease Name: FALLS LANE UNIT
License Status: Producing
License Date: 2009-07-17
Spud Date: 2009-07-24
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2009-08-04
Well Total Depth: 3673.00 ft
Configuration: Directional
Latitude: 41.320000
Longitude: -81.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-07-17 Proposed Formations:OHIO SHALE TO CLINTON, Issued Date:7/17/2009, Expired Date:7/17/2010 6:00:00 AM, Drilling unit acres:21.5, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-08-04
Correction to Well 2009-10-02 CORRECTION TO TARGET INFORMATION--FOOTAGE= 2084'SL & 341'WL OF SEC. 22; X= 2,218,760 AND Y= 605,926.
Completion Report Received 2010-02-02
Construction Permit Expires 2010-07-17
Change of Owner 2018-07-31 Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC
Record Last Modified 2018-07-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-04-20 3396 3427 85
3396 3427 85
3396 3427 85

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 200 Mscf 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 CUTTER OIL COMPANY 254.00 2159.00 105
2010 CUTTER OIL COMPANY 13294.00 5461.00 365
2011 CUTTER OIL COMPANY 14848.00 3705.00 365
2012 CUTTER OIL COMPANY 16589.00 2664.00 366
2013 CUTTER OIL COMPANY 9436.00 1609.00 365
2014 CUTTER OIL COMPANY 6652.00 1056.00 365
2015 CUTTER OIL COMPANY 4008.00 529.00 365
2016 CUTTER OIL COMPANY 2297.00 218.00 365
2017 CUTTER OIL COMPANY 3166.00 845.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 CUTTER OIL COMPANY Brine 1890 105
2010 CUTTER OIL COMPANY Brine 304 365
2011 CUTTER OIL COMPANY Brine 253 365
2012 CUTTER OIL COMPANY Brine 345 366
2013 CUTTER OIL COMPANY Brine 150 365
2014 CUTTER OIL COMPANY Brine 170 365
2015 CUTTER OIL COMPANY Brine 35 365
2016 CUTTER OIL COMPANY Brine 125 365
2017 CUTTER OIL COMPANY Brine 155 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1206510120 2010-1-11 0:00: PW No Violations
-1362527577 2018-1-26 0:00: UP No Violations 0.50
-2114393523 2015-4-2 0:00:0 UP No Violations 0.50
-393041639 2017-12-20 0:00 UP No Violations
-450775816 2009-7-21 0:00: DD No Violations
-465330827 2011-9-7 0:00:0 UP No Violations
-492157276 2010-8-24 0:00: PW No Violations
-588287231 2015-9-3 0:00:0 UP No Violations 1.00
-65862845 2013-10-28 0:00 UP No Violations
-886802453 2013-4-3 0:00:0 UP No Violations
0065862845 2013-10-28 UrbanProduction Wells No Violations The unit is producing and no changes relative to the previous inspection are noted and no problems observed.
0367991800 2009-08-11 Drill / Deepen / Reopen No Violations working on site grading location after pit was closed.
0393041639 2017-12-20 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located in a open grassy area behind a single-family residence. Fittings and connections at the wellhead pump jack and battery were secure and free from leakage or problems. The load-lines were plugged, locked, and secure. The tank lids were closed and sealed. The well was in production with an active chart record. I walked the areas surrounding the well and found no signs of problems or impacts relating to the production operation.
0450775816 2009-07-21 Drill / Deepen / Reopen No Violations Crew on site cutting trees and installing silt fence.
0465330827 2011-09-07 UrbanProduction Wells No Violations Well inspected 9/07/11. Well is in compliance with 1501-9-9-05.
0492157276 2010-08-24 Production Wells No Violations No violation.
0588287231 2015-09-03 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to a previously-issued Compliance Notice. Load-lines are now locked and secure. The leak at the brine tank has been remedied. The battery drain is secure. The 8.635-inch casing is plumbed to surface and gauged as required. The pressure indicates 25 PSI, which is within normal range. ID signage has been modified and corrected. Tank lids are closed and secure. Process safety gear (low-pressure relief valve, carbon filter, and spark arrestor are present). The violations have been remedied.
0659035562 2018-06-21 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. Fittings and connections at the well and battery were secure and free from leakage or problems. The tank lids were closed. The secondary containment was intact and dry. The individual enclosure gates were locked. Production reports were current and up-to-date. The well was in production with active chart record. The shared-use access road was in good condition. I walked and inspected the areas surrounding the wellhead and battery and found the natural greenscape to be free from signs of impact or degradation.
0886802453 2013-04-03 UrbanProduction Wells No Violations The producing unit consists of the following elements: a production wellhead and a storage tank battery. The production wellhead is fitted with a pumpjack system and is currently producing. The pumpjack unit is enclosed in an 8-foot board-on-board enclosure which is locked. The tank battery consists of 2 100-barrel steel tanks, 1 25-barrel poly tank, separator unit, and Dominion metering run. The battery is enclosed in a board-on-board enclosure. Safety equipment (carbon filter, spark arrestor, low-pressure relief valve) is present. The secondary containment is present and in good condition. No violations noted.
0944446993 2014-02-20 UrbanProduction Wells No Violations The unit is producing with no changes observed since the last inspection. No violations or problems.
0985497117 2009-08-25 Drill / Deepen / Reopen No Violations checking status of crew working on site grading and tank battery dike.
1029799439 2009-08-25 Drill / Deepen / Reopen No Violations company working on tank battery and well fencing
1037309767 2009-11-05 Production Wells No Violations No violation.
1157169064 2009-10-21 Preliminary Restoration No Violations No violation.
1206510120 2010-01-11 Production Wells No Violations no violation.
1252598700 2009-07-25 Drill / Deepen / Reopen No Violations Cemented conductor.
1254754653 2009-08-24 Drill / Deepen / Reopen No Violations Inspection found company stimulating well. No violation.
1269365195 2010-03-16 Production Wells No Violations Inspection of site found no violation well in complianceof HB278 Rules.

Stopped and talked with Mr and Mrs Dumm who live at address 8778 Falls Laneon west side near to wells tank battery I asked them if they smelt any odors last week they said no they

1354292596 2012-11-30 UrbanPreliminary Restoration No Violations My visit to the well was for an Urban Preliminary Restoration Inspection. The wellhead area is neat and clean with no violations found. The well head is encased in a board enclosure and is secured with locks. The tank battery is enclosed in a boarded fence and the is clean with no obstructions. There are two 140 BBL storage tanks with caps which are closed and secured. Each tank has a vent system. A charcoal filtering system is in place. There is one 35 BBL brine tank. There is one vertical and one horizontal separator in the unit. A metering run is in place. Pick up lines are inside unit and is secured with bull head plugs. The access road is located at 8768 Falls Lane on the left hand side. The first 100 feet is asphalt paving, then crushed limestone for the remainder. No violations were found and Urban Preliminary Restoration passes.
1362527577 2018-01-26 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. Fittings and connections at the well and battery were secure and free from leakage or problems. Load lines were plugged and locked. Tank lids were closed. The secondary containment was intact and free from standing water, or signs of leakage of petroleum fluids. The individual enclosure gates were locked. Bonding and insurance were current. Production reports were current and up-to-date. The well was in production with active chart record. The shared-use access road was in good condition. I walked and inspected the areas surrounding the wellhead and battery and found the natural greenscape to be free from signs of impact or degradation.
1421332672 2015-01-14 UrbanProduction Wells No Violations I inspected this producing unit pursuant to a complaint registered by a nearby resident. (Reference Complaint #4912). The complainant reported a loud squealing sound coming from the wellhead area. The complainant reported that the sound had been occurring for a couple of weeks. The producing unit is comprised of a wellhead with pump jack unit and tank battery is separate board-on-board enclosures located in an area of single-family homes. Access to the unit is from Falls Lane along a vacated street easement which travels west 200 feet and terminates. The well and battery are located near the terminus. Upon my inspection, I observed the wellhead to be quiet with stable and secure valve fittings and connections. During my inspection the pumping unit began a pumping cycle and I observed the drive belts to be laboring and squealing on the spindle during each rotation. I called CJ Cutter and apprised him of the observed problem . He indicated that he would have a field person go and check the unit. I did not observe any other problems. Connections and fittings at the tank battery are secure and free from signs of leakage or problems at the time of this inspection.
1423580719 2015-02-10 UrbanProduction Wells No Violations I inspected this producing unit as a follow-up to a previous complaint and subsequent inspection on 01/14/2015. The well had been reported by a neighbor to be emitting a loud noise. Upon my last inspection I observed the drive belts at the pump jack to be squealing during operation. I notified CJ Cutter about the problem. At the time of this inspection, I observed the operation of the pump jack and found it to be functioning normally with no abnormal noises.
1431700506 2015-05-08 UrbanProduction Wells Violations Noted I inspected this well location as part of routine inspection activity. The well is located in a single-family residential neighborhood. There is a short access road from Falls Lane which terminates at the wellhead. At the time of this inspection, there are no wash-outs or erosional deficits. The wellhead is comprised of a pump jack unit in a board-on-board enclosure which is locked. The tank battery is comprised of a total of two 100-barrel steel production tanks, one 50-barrel poly brine tank, and mechanical separator. The entry door is secure and locked. At the time of this inspection, the following maintenance issues were noted: Electrical boxes are not locked. Production tank lids are not latched down as required. There is secondary containment but there is no berm on the north side allowing surface runoff to enter the battery. The 8.625-inch casing is not exposed at the surface to facilitate monitoring as required. Signage is present but lacking complete information. There is discarded refuse in the wellhead enclosure which should be properly managed. The tank battery requires two doors on opposites sides. An empty 55-gallon drum and chemical pump should be removed if not used. Carbon filters must be periodically evaluated for properly operation. In addition, the following safety issues were noted. Load lines are not locked. Brine is actively leaking from the 2-inch flange at the brine tank. The drain for the battery secondary containment has been left open. These safety issues must be remedied as soon as practicable or by 06/19/2015. Please contact Inspector Stephen Tompkins with questions regarding this Compliance Notice.
1550685591 2019-02-19 Production Wells No Violations On Location to investigate Complaint # 6077, that was received on 02-15-2019 Regarding noise from the well. The well that is emitting a loud noise is approximately 380 feet to the northwest of the landowner. On 02-15-2019 I phone Ed Cutright from EOS Energy, to respond to the site and check out the issue of noise. I was informed by CJ Cutter that the pivot bearing needed greased. At the time of this inspection, the pump jack was not in operation. No compliance issues were found.
1779001083 2010-05-19 Production Wells No Violations on site inspected well and tank battery no violation found.
2114393523 2015-04-02 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and tank battery are located in a meadow behind the house at the referenced address. Fittings and connections at the wellhead pump jack and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. No problems noted at the time of this inspection.
367991800 2009-8-11 0:00: DD No Violations
659035562 2018-6-21 0:00: UP No Violations
944446993 2014-2-20 0:00: UP No Violations
985497117 2009-8-25 0:00: DD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1431700506 US-OH-112624 2015-11-13 LOCKS
1431700506 US-OH-112625 2015-11-13 Well operation causing pollution and contamination
1431700506 US-OH-112626 2015-11-13 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References