X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22089

Well Details

Well ID: 34-035-22089
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: McCOMSEY UNIT
License Status: Producing
License Date: 2010-04-29
Spud Date: 2010-06-21
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2010-06-24
Well Total Depth: 3630.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -81.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-01 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:12/1/2008, Expired Date:12/1/2009 6:00:00 AM, Drilling unit acres:20.79, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2010-04-29 Proposed Formations:ORISKANY/NEWBURG/CLINTON, Issued Date:4/29/2010, Expired Date:4/29/2011 6:00:00 AM, Drilling unit acres:20.79, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-06-24
Completion Report Received 2010-09-07
Construction Permit Expires 2011-04-29
Change of Owner 2018-08-21 Operator changed from 3434, GONZOIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2018-08-21

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-11-08 3486 3502 20
3486 3502 20
3486 3502 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72028 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 GONZOIL INC 45717.00 340.00 365
2012 GONZOIL INC 36601.00 230.00 366
2013 GONZOIL INC 22798.00 84.00 365
2014 GONZOIL INC 15094.00 121.00 365
2015 GONZOIL INC 10613.00 92.00 365
2016 GONZOIL INC 8294.00 72.00 365
2017 GONZOIL INC 6631.00 104.00 365
2018 GONZOIL INC 1140.00 0.00 180

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 GONZOIL INC Brine 635 365
2012 GONZOIL INC Brine 200 366
2013 GONZOIL INC Brine 248 365
2014 GONZOIL INC Brine 140 365
2015 GONZOIL INC Brine 110 365
2016 GONZOIL INC Brine 80 365
2017 GONZOIL INC Brine 68 365
2018 GONZOIL INC Brine 0 180

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-430710864 2010-4-22 0:00: DD No Violations
-999511332 2010-4-20 0:00: AM No Violations
0430710864 2010-04-22 Drill / Deepen / Reopen No Violations cementing surface casing.
0682659166 2010-04-23 Drill / Deepen / Reopen No Violations drilling on fluid at 1360
0999511332 2010-04-20 Administrative Inspection No Violations Held on site meeting to discuss on site construction and permit condittions.
1374165495 2013-07-18 UrbanPreliminary Restoration No Violations The producing unit consists of a wellhead with pumpjack unit and an aboveground storage tank (AST) battery with one steel 140-barrel production tank, one ploy 50-barrel brine tank, mechanical separator, and metering run. The unit ID is present and meets requirements. The loadouts are locked and bull-plugged. Tank spacing meets the requirements. The battery secondary containment is good. The wellhead and battery are in separate chain-link enclosures. Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills. The access road is graveled and in good condition. Preliminary restoration passes.
1404465649 2010-04-22 Drill / Deepen / Reopen No Violations BOP testing passed.
1501685094 2017-08-02 UrbanProduction Wells No Violations I inspected this production well as part of routine inspection activity. The well and associated battery are located at the back of a residential parcel. The dedicated portion of the access road, which extends northward from the end of the shared driveway. Was in good condition. Fittings and connections at the well and battery were secure. The secondary containment was intact and free from signs of spills or leaks. The load lines were locked and secure. I walked the areas surrounding the well and battery and found no signs of impact or degradation to the natural greenscape.
1751774162 2015-03-30 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead and battery are located behind the single-family residence at the referenced address. Access to the well and battery are from the dedicated access road adjacent to the main driveway. The wellhead is comprised of a pump jack system. Fittings and connections are secure. The tank battery is comprised of 1 100-barrel steel production tank, 1 50-barrel poly brine tank and separator unit in a separate chain-link enclosure. Elements of the system are in general good repair. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well.
1761588354 2014-02-26 UrbanProduction Wells No Violations The producing unit is comprised of a wellhead with pump jack and aboveground storage tank (AST) battery with 1 100-barrel steel production tank, 1 25 barrel poly brine tank, separator, and Dominion metering run. The wellhead and battery are enclosed in separate chain-link fences. Locks, ID placard, process safety equipment are present. No problems or violations noted.
1985623940 2018-01-03 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and tank battery are located on a larger, residential parcel, with a shared-use driveway. I found the wellhead pump jack and tank battery connections to be secure and free from leakage or problems. The load-lines were locked and secure. Enclosure gates were locked and secure. Production reports were current. The well was in production with an active chart record. I walked and inspected the areas surrounding the well and battery and found no signs of problems. There were several inches of snow in a area.
2079654603 2010-04-21 Drill / Deepen / Reopen No Violations Cementing conductor
682659166 2010-4-23 0:00: DD No Violations

For data sources see[9]

References