X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22076

Well Details

Well ID: 34-035-22076
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: SUSSEN UNIT
License Status: Producing
License Date: 2008-10-03
Spud Date: 2008-11-17
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-11-24
Well Total Depth: 3550.00 ft
Configuration: Vertical
Latitude: 41.430000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-03 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:10/3/2008, Expired Date:10/3/2009 6:00:00 AM, Drilling unit acres:21.45, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-11-24
Completion Report Received 2009-04-24
Construction Permit Expires 2009-10-03
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-07-08 3350 3391 48
3350 3391 48
3350 3391 48

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 52530 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 BASS ENERGY CO INC 12946.00 67.00 321
2010 BASS ENERGY CO INC 23591.00 113.00 365
2011 BASS ENERGY CO INC 11039.00 0.00 0
2012 BASS ENERGY CO INC 7287.00 0.00 366
2013 BASS ENERGY CO INC 4781.00 68.00 365
2014 BASS ENERGY CO INC 3574.00 0.00 365
2015 BASS ENERGY CO INC 2913.00 0.00 365
2016 BASS ENERGY CO INC 2621.00 0.00 365
2017 BASS ENERGY CO INC 2019.00 0.00 365
2018 BASS ENERGY CO INC 1712.00 37.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 BASS ENERGY CO INC Brine 322 321
2010 BASS ENERGY CO INC Brine 145 365
2011 BASS ENERGY CO INC Brine 147
2012 BASS ENERGY CO INC Brine 35 366
2013 BASS ENERGY CO INC Brine 89 365
2014 BASS ENERGY CO INC Brine 0 365
2015 BASS ENERGY CO INC Brine 65 365
2016 BASS ENERGY CO INC Brine 0 365
2017 BASS ENERGY CO INC Brine 45 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1681481145 2009-4-27 0:00: DD No Violations
-48831346 2008-10-1 0:00: DD No Violations
-83670542 2008-11-18 0:00 DD No Violations
-947750620 2008-11-24 0:00 DD No Violations
0048831346 2008-10-01 Drill / Deepen / Reopen No Violations Location made
0083670542 2008-11-18 Drill / Deepen / Reopen No Violations drilling 207
0187947188 2013-07-08 UrbanPreliminary Restoration No Violations The producing unit consists of a an above-ground storage tank (AST) battery with 1 140-barrel steel production tank, and 1 50-barrel steel brine tank, a mechanical separator, and metering run. Identification is present. There is an earthen secondary containment which is in good condition. The load-outs are bull-plugged and locked. Safety equipment is present. The wellhead is located 100 feet north of the battery. The wellhead consists of a mechanical plunger lift system and associated valve-tree. The annulus is plumbed into the production line. The wellhead and battery are in separate board-on-board enclosures which are locked. The lease road is primarily shared with the residential driveway. A small dedicated portion is paved with mixed, coarse limestone aggregate. I did not observe any problems or violations. Preliminary restoration passes.
0803235557 2008-12-23 Drill / Deepen / Reopen No Violations well being frac
0947750620 2008-11-24 Drill / Deepen / Reopen No Violations cementing 4.5 casing
1332967534 2015-02-27 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located within the confines of a farmstead property on the west side of Chagrin River Road. The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. At the time of this inspection there are 15 to 20 inches of snow cover in the area which obscures some surficial elements from observation.
1451453323 2008-11-19 Drill / Deepen / Reopen No Violations surface cementing
1681481145 2009-04-27 Drill / Deepen / Reopen No Violations working on restoation ground has been to wet
1841836516 2017-07-07 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located within a farmstead property. The wellhead plunger lift and battery are in separate board-on-board enclosures which are locked. Fittings and connections are secure and free from signs of leakage or problems. The load-outs are secure, plugged, and locked. Process safety gear is present. Signage is in place and current. The secondary containment was intact. I walked the areas surrounding the well and battery and found no observable sign of degradation to the surrounding greescape.
187947188 2013-7-8 0:00:0 UL No Violations
2012770182 2009-11-09 Preliminary Restoration No Violations no violations.
803235557 2008-12-23 0:00 DD No Violations

For data sources see[9]

References