X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22038

Well Details

Well ID: 34-035-22038
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: HOLIDAY INN UNIT
License Status: Producing
License Date: 2008-05-07
Spud Date: 2008-08-13
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-08-20
Well Total Depth: 3525.00 ft
Configuration: Vertical
Latitude: 41.530000
Longitude: -81.440000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-05-07 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:5/7/2008, Expired Date:5/7/2009 6:00:00 AM, Drilling unit acres:24.3, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-08-20
Completion Report Received 2009-03-23
Construction Permit Expires 2009-05-07
Correction to Well 2010-02-12 UNIT SIZE REDUCED TO 22.14 ACRES.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-05 3320 3350 61
3320 3350 61
3320 3350 61

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 76320 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 BASS ENERGY CO INC 95696.00 0.00 287
2010 BASS ENERGY CO INC 120682.00 0.00 365
2011 BASS ENERGY CO INC 94854.00 0.00 0
2012 BASS ENERGY CO INC 72552.00 0.00 366
2013 BASS ENERGY CO INC 54063.00 0.00 365
2014 BASS ENERGY CO INC 43191.00 32.00 365
2015 BASS ENERGY CO INC 47498.00 0.00 365
2016 BASS ENERGY CO INC 44259.00 0.00 365
2017 BASS ENERGY CO INC 39375.00 0.00 365
2018 BASS ENERGY CO INC 37559.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 BASS ENERGY CO INC Brine 307 287
2010 BASS ENERGY CO INC Brine 210 365
2011 BASS ENERGY CO INC Brine 111
2012 BASS ENERGY CO INC Brine 54 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 70 365
2015 BASS ENERGY CO INC Brine 95 365
2016 BASS ENERGY CO INC Brine 36 365
2017 BASS ENERGY CO INC Brine 80 365
2018 BASS ENERGY CO INC Brine 25 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1128383586 2008-8-26 0:00: DD No Violations
-1201126151 2008-8-14 0:00: DD No Violations
-1364400598 2017-8-16 0:00: UP No Violations 0.50
-1694488208 2009-4-27 0:00: PL No Violations
-1781478254 2012-1-11 0:00: UP No Violations 1.00
-1801522833 2009-11-30 0:00 PW No Violations
-791002372 2008-8-28 0:00: DD No Violations
-985748520 2008-8-12 0:00: DD No Violations
0147740352 2013-01-08 UrbanProduction Wells No Violations The producing unit is comprised of a two-tank battery (2 140-barrel, 1 20-barrel) with mechanical separator and wellhead valve assembly. The tank battery is enclosed in an 8-foot enclosure. A mechanical plunger lift is affixed to the wellhead. The well is currently producting. The secondary containment is adequate. Unit identification is present and legible at the tank battery. I did not observe any leaks, spills, or other signs of contamination.
0178856631 2008-09-17 Drill / Deepen / Reopen No Violations setting fence
0315843029 2008-08-20 Drill / Deepen / Reopen No Violations 4.5 casing cement job
0523306956 2009-09-23 Production Wells No Violations
0650972507 2008-10-29 Drill / Deepen / Reopen No Violations site insection tank battery
0756568130 2018-05-30 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, the enclosure gates were locked. The load line valves were secure. The tank lids were closed. The well was in active production with a current chart record. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of paved parking and drive areas. I did not observe any signs of problems.
0791002372 2008-08-28 Drill / Deepen / Reopen No Violations on site parking lot clean no mud crew on site logging well.
0837273179 2008-08-12 Drill / Deepen / Reopen No Violations working on making location .
0965465542 2008-08-15 Drill / Deepen / Reopen No Violations surface
0985748520 2008-08-12 Drill / Deepen / Reopen No Violations no violation
1128383586 2008-08-26 Drill / Deepen / Reopen No Violations working on location
1135489379 2017-08-11 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection in which I had noted that the former area of the pits had become severely heaved, causing significant, large longitudinal cracks in the over-lying asphalt paving, rending this portion of the parking lot unusable. I had notified the owner about the observed condition. At the time of this inspection, work to remedy the heaving was on-going, and expected to be completed soon.
1201126151 2008-08-14 Drill / Deepen / Reopen No Violations drilling no violation
1225897017 2008-08-15 Drill / Deepen / Reopen No Violations surface
1364400598 2017-08-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity and a follow-up to a previous inspection in which I had noted that the area of the former pit was showing some signs of heaving. Specifically, the asphalt paving had become heaved up by several inches along an east to west trend, co-incident with the former location of the drilling pit. I had notified Bass Energy about the heaving and measures to correct the heaving had been undertaken.. At the time of this inspection, I observed that the heaved area had been effectively remedied, and was level with the surrounding area. I also inspected the production elements. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of paved parking and drive areas. I did not observe any signs of problems.
147740352 2013-1-8 0:00:0 UP No Violations
1489430500 2017-03-13 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection. At the time of this inspection I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures which were locked and secure. The valves and connections at both the well and battery were secure and free from signs of leakage. Process safety equipment was present. ID signage was present and accurate. The areas surrounding the well and battery were comprised of asphalt parking and drive areas for the hotel facility located on the parcel. I walked the surrounding areas and found no signs of impacts or degradation. Access to the well and battery was afforded by shared-use, asphalt-paved driveway which was in good condition. I noted that the asphalt paving near the wellhead was heaved up along a more-or-less east-west axis. I notified Ralph Gregory about the heaving. I advised that it should be evaluated to assess whether the heaving is related to the drilling or production activity.
1694488208 2009-04-27 Preliminary Restoration No Violations
1781478254 2012-01-11 UrbanProduction Wells No Violations On 01/11/2012, DNR Inspector Richard Skidmore completed an urban production well inspection status check for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
178856631 2008-9-17 0:00: DD No Violations
1801522833 2009-11-30 Production Wells No Violations No violation
1992936051 2015-02-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead mechanical plunger lift and tank battery enclosures are locked and secure. System fittings and connections are secure and free from signs of leakage or problems. Load-outs are plugged, locked and secure. ID signage is present and accurate. Access to the unit is shared with the Holiday Inn. At the time of this inspection, there is 12 to 14 inches of snow cover which obscures some surficial features.
315843029 2008-8-20 0:00: DD No Violations
523306956 2009-9-23 0:00: PW No Violations
650972507 2008-10-29 0:00 DD No Violations
756568130 2018-5-30 0:00: UP No Violations 1.00
837273179 2008-8-12 0:00: DD No Violations
965465542 2008-8-15 0:00: DD No Violations

For data sources see[9]

References