34-035-22007

Well Details

Well ID: 34-035-22007
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: AFT UNIT
License Status: Producing
License Date: 2017-11-02
Spud Date: 2008-03-13
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-03-17
Well Total Depth: 3568.00 ft
Configuration: Vertical
Latitude: 41.310000
Longitude: -81.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-11-14 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:11/14/2007, Expired Date:11/13/2008 6:00:00 AM, Drilling unit acres:22.75, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-03-17 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17.
Completion Report Received 2008-11-06 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17.
APP 2015-06-03 Proposed Formations:CLINTON, Issued Date:6/3/2015, Expired Date:6/2/2017 12:00:00 PM, Drilling unit acres:22.75, Proposed Well Type:OG, Proposed Well Class:
APP 2017-11-02 Proposed Formations:CLINTON, Issued Date:11/2/2017, Expired Date:11/2/2019 12:00:00 PM, Drilling unit acres:22.75, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2017-12-11 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17.
Construction Permit Expires 2019-11-02 UPDATED COORDINATES PER DOGRM SURVEYOR-ALE 12/11/17.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-12-16 3422 3439 30
3422 3439 30
3422 3439 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 53040 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 BASS ENERGY CO INC 1745.00 133.00 209
2009 BASS ENERGY CO INC 1958.00 235.00 365
2010 BASS ENERGY CO INC 1526.00 197.00 365
2011 BASS ENERGY CO INC 776.00 91.00 0
2012 BASS ENERGY CO INC 814.00 156.00 366
2013 BASS ENERGY CO INC 593.00 156.00 365
2014 BASS ENERGY CO INC 526.00 93.00 365
2015 BASS ENERGY CO INC 13.00 0.00 365
2016 BASS ENERGY CO INC 0.00 0.00 0
2017 BASS ENERGY CO INC 0.00 0.00 0
2018 BASS ENERGY CO INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 BASS ENERGY CO INC Brine 94 209
2009 BASS ENERGY CO INC Brine 185 365
2010 BASS ENERGY CO INC Brine 183 365
2011 BASS ENERGY CO INC Brine 65
2012 BASS ENERGY CO INC Brine 65 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 125 365
2015 BASS ENERGY CO INC Brine 0 365
2016 BASS ENERGY CO INC Brine 0 0
2017 BASS ENERGY CO INC Brine 0 0
2018 BASS ENERGY CO INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1041623490 2014-12-29 0:00 UP No Violations
-109484665 2017-5-24 0:00: UP No Violations 0.50
-1697369140 2013-6-6 0:00:0 UL No Violations
-1948189391 2015-4-2 0:00:0 UP No Violations 0.50
-2131882120 2008-3-11 0:00: DD No Violations
-424890544 2008-3-18 0:00: DD No Violations
0064510422 2008-04-22 Production Wells No Violations
0094147930 2008-04-15 Drill / Deepen / Reopen No Violations complaint of noise coming from site but rig is gone

on site inspection found company running tubing and working on restoation.

0109484665 2017-05-24 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well and battery are located behind a residential parcel on Broadview Road. The well and tank battery is are located at the back portion of the parcel and accessed via a separate dedicated road. At the time of this inspection, I observed the following: Fittings and connections at the wellhead and battery were secure and free from leakage. The load-line valves were closed and plugged but missing locks. Tank lids were closed and secure. Individual enclosure gates were locked and secure. I noted that the access road has become overgrown with grassy vegetation. I notified Bass Energy about the need for maintenance at the lease road. I inspected both the interior areas and exterior portions of the well and battery and surrounding areas and found no signs of impact or problem.
0297699353 2008-03-13 Drill / Deepen / Reopen No Violations on site for surface job
0424890544 2008-03-18 Drill / Deepen / Reopen No Violations no violation
1016026803 2011-08-03 UrbanPreliminary Restoration No Violations Urban Preliminary Inspection due. Restoration Passed
1041623490 2014-12-29 UrbanProduction Wells No Violations I inspected the producing unit as part of routine inspection activity. The wellhead and battery are located behind a residence on Broadview Road and shares a portion of the driveway. The gravel-paved access road then proceeds to the east and terminates at the unit location. The wellhead and battery are in separate chain-link enclosures. Fittings and connections are free from signs of problems or signs of leakage. The load outs are plugged and the gates are locked. Secondary containment is dry and clean.
1583758775 2020-3-9 0:00:0 UP No Violations 0.50
1697369140 2013-06-06 UrbanPreliminary Restoration No Violations The unit consists of a production wellhead with a mechanical plunger lift, and a storage tank battery. The wellhead and battery are enclosed in separate chain-link enclosures, which are locked. Unit ID is present. The tank battery consists of 2 140-barrel tanks and 1 25 barrel tank, and a mechanical separator. HB 278 equipment is present. I did not observe any problems or violations, This unit passes preliminary restoration.
1948189391 2015-04-02 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and tank battery are located in a meadow behind the house at the referenced address. The well is comprised of a mechanical plunger lift system in a chain-link enclosure. The battery is comprised of 1 100-barrel steel production tank, 1 50-barrel steel brine tank, and mechanical separator. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems. Load-outs are secure. Gates are locked. Process safety equipment is present. The access road is good, passable condition with no washouts or other erosional deficits or signs of impact.
2131882120 2008-03-11 Drill / Deepen / Reopen No Violations rig moving on site
297699353 2008-3-13 0:00: DD No Violations
64510422 2008-4-22 0:00: PW No Violations
94147930 2008-4-15 0:00: DD No Violations

For data sources see[9]

References