34-035-21902

Well Details

Well ID: 34-035-21902
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CUYAHOGA HEIGHTS BOE
License Status: Producing
License Date: 2006-05-02
Spud Date: 2006-06-21
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-06-28
Well Total Depth: 3100.00 ft
Configuration: Vertical
Latitude: 41.420000
Longitude: -81.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-05-02 Proposed Formations:CLINTON, Issued Date:5/2/2006, Expired Date:5/2/2007 6:00:00 AM, Drilling unit acres:24.4, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-06-21
Completed 2006-06-28
Reached Total Depth 2006-06-28
Completion Report Received 2006-08-25
Construction Permit Expires 2007-05-02
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-11-22 2846 2876 52
2846 2876 52
2846 2876 52

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 M & M ROYALTY LTD 0.00 113.00 365
2007 M & M ROYALTY LTD 2150.00 1225.00 365
2008 M & M ROYALTY LTD 1901.00 861.00 365
2009 M & M ROYALTY LTD 1269.00 722.00 365
2010 M & M ROYALTY LTD 1191.00 627.00 365
2011 M & M ROYALTY LTD 906.00 338.00 365
2012 M & M ROYALTY LTD 656.00 688.00 366
2013 M & M ROYALTY LTD 258.00 447.00 365
2014 M & M ROYALTY LTD 77.00 222.00 365
2015 M & M ROYALTY LTD 59.00 0.00 31
2016 SOUND ENERGY CO INC 66.00 104.00 365
2017 SOUND ENERGY CO INC 143.00 349.00 365
2018 SOUND ENERGY CO INC 90.00 230.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 M & M ROYALTY LTD Brine 0 365
2007 M & M ROYALTY LTD Brine 504 365
2008 M & M ROYALTY LTD Brine 299 365
2009 M & M ROYALTY LTD Brine 175 365
2010 M & M ROYALTY LTD Brine 210 365
2011 M & M ROYALTY LTD Brine 70 365
2012 M & M ROYALTY LTD Brine 308 366
2013 M & M ROYALTY LTD Brine 197 365
2014 M & M ROYALTY LTD Brine 0 365
2015 SOUND ENERGY CO INC Brine 0 305
2016 SOUND ENERGY CO INC Brine 0 365
2017 SOUND ENERGY CO INC Brine 0 365
2018 SOUND ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1292917431 2013-2-27 0:00: UL No Violations
-225421327 2017-2-9 0:00:0 UP No Violations 1.00
-99872288 2007-1-31 0:00: DD No Violations
0099872288 2007-01-31 Drill / Deepen / Reopen No Violations company working on fenceing
0225421327 2017-02-09 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery is separate chain-link enclosures. The enclosure gates were locked and secure. The dedicated access road was in good condition. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. I walked the areas around the wellhead and battery and found no evidence of impact, degradation, or erosional deficits. Production reports were current.
0324309434 2017-11-09 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system located remotely behind the school building. The associated tank battery is located in a separate chain-link enclosure. The enclosure gates were locked. Fitings and connections at both the wellhead and battery were secure. Load-line valves were plugged, locked and secure. The well was in active production. The tank lids were closed and secure. Secondary containment was intact and the interior areas were dry and free from signs of leakage or problems. I walked and inspected the areas around the wellhead and battery and found no evidence of impact or environmental degradation relating to the on-going production activity.
1154348147 2006-06-16 Drill / Deepen / Reopen No Violations
1292917431 2013-02-27 UrbanPreliminary Restoration No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6 enclosure. The tank battery is comprised of 2 100-barrel (BBL) tanks, 1 50 BBL tank, mechanical separator, and associated piping and appurtenances enclosed in an 8 enclosure. The loadout lines are locked and the secondary containment is good. I did not observe any leaks, releases, or problems.
1407763920 2006-06-28 Drill / Deepen / Reopen No Violations on site inspection found no violation silt fence up good order pits ok
324309434 2017-11-9 0:00: UP No Violations 0.50

For data sources see[9]

References