If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-21873 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.29,"lon":-81.66,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: CLEVELAND/SENECA GOLF COURSE | |
License Status: Producing | |
License Date: 2005-12-02 | |
Spud Date: 2006-04-03 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-04-06 | |
Well Total Depth: 3717.00 ft | |
Configuration: Vertical | |
Latitude: 41.290000 | |
Longitude: -81.660000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-12-02 | Proposed Formations:CLINTON, Issued Date:12/2/2005, Expired Date:12/2/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EOUT |
Original Spud | 2006-04-03 | RBDMS Rec |
Completed | 2006-04-06 | RBDMS Rec |
Reached Total Depth | 2006-04-06 | RBDMS Rec |
Completion Report Received | 2006-11-07 | RBDMS Rec |
Construction Permit Expires | 2006-12-02 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-01-11 | 3528 | 3574 | 63 |
3528 | 3574 | 63 | |
3528 | 3574 | 63 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 47996 Gal | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | BASS ENERGY CO INC | 4762.00 | 132.00 | 365 |
2007 | BASS ENERGY CO INC | 6519.00 | 82.00 | 365 |
2008 | BASS ENERGY CO INC | 7767.00 | 160.00 | 365 |
2009 | BASS ENERGY CO INC | 3218.00 | 77.00 | 365 |
2010 | BASS ENERGY CO INC | 9139.00 | 96.00 | 365 |
2011 | BASS ENERGY CO INC | 7638.00 | 79.00 | 0 |
2012 | BASS ENERGY CO INC | 7641.00 | 39.00 | 366 |
2013 | BASS ENERGY CO INC | 6212.00 | 81.00 | 365 |
2014 | BASS ENERGY CO INC | 5928.00 | 34.00 | 365 |
2015 | BASS ENERGY CO INC | 5789.00 | 0.00 | 365 |
2016 | BASS ENERGY CO INC | 5350.00 | 44.00 | 365 |
2017 | BASS ENERGY CO INC | 5130.00 | 38.00 | 365 |
2018 | BASS ENERGY CO INC | 4794.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | BASS ENERGY CO INC | Brine | 105 | 365 |
2007 | BASS ENERGY CO INC | Brine | 87 | 365 |
2008 | BASS ENERGY CO INC | Brine | 27 | 365 |
2009 | BASS ENERGY CO INC | Brine | 112 | 365 |
2010 | BASS ENERGY CO INC | Brine | 58 | 365 |
2011 | BASS ENERGY CO INC | Brine | 62 | |
2012 | BASS ENERGY CO INC | Brine | 59 | 366 |
2013 | BASS ENERGY CO INC | Brine | 30 | 365 |
2014 | BASS ENERGY CO INC | Brine | 31 | 365 |
2015 | BASS ENERGY CO INC | Brine | 52 | 365 |
2016 | BASS ENERGY CO INC | Brine | 38 | 365 |
2017 | BASS ENERGY CO INC | Brine | 39 | 365 |
2018 | BASS ENERGY CO INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-115284116 | 2017-6-30 0:00: | UP | No Violations | 0.50 |
-1975296943 | 2013-7-18 0:00: | UL | No Violations | |
-401930672 | 2015-3-30 0:00: | UP | No Violations | 0.50 |
-800383031 | 2018-9-11 0:00: | UP | No Violations | 1.00 |
-890352410 | 2006-4-3 0:00:0 | DD | No Violations | |
0115284116 | 2017-06-30 | UrbanProduction Wells | No Violations | I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery. The well is located on golf course property and accessed from Edgerton Road. The shared battery (shared with #2-1852) is located on an otherwise undeveloped property located along Barr Road. The individual enclosures were locked and secure. The load-line valves were locked and plugged. The dedicated lease roads were exhibiting some potholes and wear but was passable. Fittings and connections were secure and free from signs of leakage or problems. |
0401930672 | 2015-03-30 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. The wellhead is located on the golf course, east of the clubhouse. The battery is located on the west side of Barr Rd, in a wooded area on the east side of the Seneca Gold Club. Access to battery is from a dedicated access road from Barr Rd. The wellhead is comprised of a plunger lift system in a locked chain-link enclosure. Fittings and connections are secure. The tank battery is comprised of 1100-barrel steel production tank and separator unit in a separate chain-link enclosure. Elements of the system are in general good repair. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well. The battery is shared with the Cleveland/Seneca GC #2-1852 well which is located off Barr Rd adjacent to the battery. |
0800383031 | 2018-09-11 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I found the following: the wellhead plunger lift system was in production. Fittings and connections were secure and free from signs of problems or leakage. The chain-link enclosure was locked and secure. The associated tank battery, which is shared with the Seneca Golf Course #1 well, located near the battery, on Barr Rd. The battery enclosure gate was locked and secure. The load lines were plugged and secure. The interior of the battery was dry and free from signs of leaks, spills, or other problems. The chart record was active. I walked the areas surrounding the well, including the access road, and found the surface conditions to be free from signs of impact. |
0890352410 | 2006-04-03 | Drill / Deepen / Reopen | No Violations | surface being set |
1313079113 | 2011-08-02 | UrbanPreliminary Restoration | No Violations | Preliminary Restoration Inspection - passed. |
1778986137 | 2006-04-03 | Drill / Deepen / Reopen | No Violations | surface being set mud on road being removed with bobcat.Road being as clean as possible. |
1975296943 | 2013-07-18 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a wellhead with mechanical plunger lift unit and an aboveground storage tank (AST) battery with one steel 140-barrel production tank, one stee 50-barrel brine tank, mechanical separator, and metering run.. The unit ID is present and meets requirements. The loadouts are locked and bull-plugged. Tank spacing meets the requirements. The battery secondary containment is good. The wellhead and battery are in separate chain-link enclosures. Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills. The battery is shared with the Seneca G. C. Unit #1 (3403521852). The access road gate is not locked. The gate needs an ID placard. Preliminary restoration passes. |
258314446 | 2020-1-23 0:00: | UP | No Violations |
For data sources see[9]