34-035-21852

Well Details

Well ID: 34-035-21852
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CLEVELAND/SENECA GOLF COURSE
License Status: Producing
License Date: 2005-09-20
Spud Date: 2005-10-17
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-10-24
Well Total Depth: 3723.00 ft
Configuration: Vertical
Latitude: 41.290000
Longitude: -81.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-09-20 Proposed Formations:CLINTON, Issued Date:9/20/2005, Expired Date:9/20/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:EOUT
Original Spud 2005-10-17 RBDMS Rec
Completed 2005-10-24 RBDMS Rec
Reached Total Depth 2005-10-24 RBDMS Rec
Construction Permit Expires 2006-09-20 RBDMS Rec
Completion Report Received 2006-11-07 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-01-11 3559 3591 42
3559 3591 42
3559 3591 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 51260 Gal 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 BASS ENERGY CO INC 13312.00 287.00 365
2007 BASS ENERGY CO INC 6226.00 82.00 365
2008 BASS ENERGY CO INC 7767.00 160.00 365
2009 BASS ENERGY CO INC 3216.00 222.00 365
2010 BASS ENERGY CO INC 9134.00 96.00 365
2011 BASS ENERGY CO INC 7636.00 79.00 0
2012 BASS ENERGY CO INC 7633.00 39.00 366
2013 BASS ENERGY CO INC 6206.00 81.00 365
2014 BASS ENERGY CO INC 5924.00 34.00 365
2015 BASS ENERGY CO INC 5791.00 139.00 365
2016 BASS ENERGY CO INC 5350.00 44.00 365
2017 BASS ENERGY CO INC 5130.00 38.00 365
2018 BASS ENERGY CO INC 4794.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 BASS ENERGY CO INC Brine 153 365
2007 BASS ENERGY CO INC Brine 87 365
2008 BASS ENERGY CO INC Brine 27 365
2009 BASS ENERGY CO INC Brine 114 365
2010 BASS ENERGY CO INC Brine 57 365
2011 BASS ENERGY CO INC Brine 62
2012 BASS ENERGY CO INC Brine 59 366
2013 BASS ENERGY CO INC Brine 30 365
2014 BASS ENERGY CO INC Brine 30 365
2015 BASS ENERGY CO INC Brine 52 365
2016 BASS ENERGY CO INC Brine 38 365
2017 BASS ENERGY CO INC Brine 38 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1524832569 2005-10-13 0:00 DD No Violations 1.00
-1783391967 2020-1-23 0:00: UP No Violations
-2121000402 2016-6-3 0:00:0 UP No Violations 2.00
-433158165 2015-3-30 0:00: UP No Violations 0.50
-866952457 2017-6-30 0:00: UP No Violations 0.50
0182977512 2018-09-11 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I found the following: the wellhead plunger lift system was in production. Fittings and connections were secure and free from signs of problems or leakage. The chain-link enclosure was locked Ans secure. The associated tank battery, which is shared with the Seneca Golf Course #2 well, located west of the #1 well, within the golf course facility. The battery enclosure gate was locked and secure. The load lines were plugged and secure. The interior of the battery was dry and free from signs of leaks, spills, or other problems. The chart record was active. I walked the areas surrounding the well, including the access road, and found the surface conditions to be free from signs of impact.
0433158165 2015-03-30 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The wellhead and battery are located on the west side of Barr Rd, in a wooded area on the east side of the Seneca Gold Club. Access to the well and battery are from a dedicated access road from Barr Rd. The wellhead is comprised of a plunger lift system in a locked chain-link enclosure. Fittings and connections are secure. The tank battery is comprised of 1100-barrel steel production tank and separator unit in a separate chain-link enclosure. Elements of the system are in general good repair. Fittings and connections are secure and free from signs of leakage at the time of this inspection. The load-outs are plugged and secure. ID signage and secondary containment are present. Areas surrounding the wellhead and battery are reasonably well drained and free from signs of adverse impact from the on-going production activity associated with this well. The battery is shared with the Cleveland/Seneca GC #2-1873 well which is located west.
0866952457 2017-06-30 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery. The well and battery shared battery (shared with #2-1873 are located on the eastern portion of a wooded parcel and accessed from Barr Road. The individual enclosures were locked and secure. The load-line valves were locked and plugged. The dedicated lease road was exhibiting some grassy over-growth and wear but was passable. Fittings and connections were secure and free from signs of leakage or problems. I walked the areas surrounding the well and battery and found no signs of impact to the natural greenscape.
1374162456 2013-07-18 Preliminary Restoration No Violations The producing unit consists of a wellhead with mechanical plunger lift unit and an aboveground storage tank (AST) battery with one steel 140-barrel production tank, one steel 50-barrel brine tank, mechanical separator, and metering run. The unit ID is present and meets requirements. The load-outs are locked and bull-plugged. Tank spacing meets the requirements. The battery secondary containment is good. The wellhead and battery are in separate chain-link enclosures. Safety equipment is present in accordance with 1501:9-9-05E. I did not observe any evidence of leakage or spills. The battery is shared with the Seneca G. C. Unit #1 (3403521873). The access road gate is locked and there is an ID placard. Preliminary restoration passes.
1524832569 2005-10-13 Drill / Deepen / Reopen No Violations Tree company clearing trees on drilling location. When completed Bass Energy will prepare location for drilling. Cloudy, 65 degrees.
182977512 2018-9-11 0:00: UP No Violations 1.00
1929869082 2006-03-28 Production Wells No Violations tank battery set area leveled
2121000402 2016-06-03 UrbanProduction Wells No Violations I inspected this producing well pursuant to a complaint (# 5344) from a nearby landowner. The complainant had been experiencing an unknown odor in the basement of his house, located approximately 600 feet southeast of the well location and was trying to rule out possible sources. At the time of this inspection, I observed the following: a wellhead with plunger lift system in a locked chain-link enclosure. Fittings and connections were secure. The tank battery was comprised of one 100-barrel steel production tank and separator unit in a separate chain-link enclosure. Elements of the system were in good repair with no evidence of leakage, spills, or degradation to the surrounding natural landscape. As part of this inspection, I met with Ralph Gregory, representative of Bass Energy Co., Inc. Mr. Gregory reports no problems with the on-going production at the well.

For data sources see[9]

References