X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21825

Well Details

Well ID: 34-035-21825
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CHURCH OF THE GOOD SHEPHERD UNIT
License Status: Producing
License Date: 2004-12-02
Spud Date: 2004-12-07
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-12-15
Well Total Depth: 3669.00 ft
Configuration: Directional
Latitude: 41.500000
Longitude: -81.510000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-12-02 Proposed Formations:CLINTON, Issued Date:12/2/2004, Expired Date:12/2/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-12-07 DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27-
Completed 2004-12-15 DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27-
Reached Total Depth 2004-12-15 DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27-
Completion Report Received 2005-02-17 DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27-
Correction to Well 2005-03-25 CORRECTION TO TARGET INFORMATION: FOOTAGE= 624'SL & 1154'EL OF LOT 73; X= 2,270,760; Y= 670,550.
Construction Permit Expires 2005-12-02 DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27-
Record Last Modified 2017-02-15 DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27-

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-04-07 3484 3536 35
3484 3536 35
3484 3536 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 56078 Gal 30000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 BASS ENERGY CO INC 19592.00 89.00 365
2006 BASS ENERGY CO INC 36751.00 92.00 365
2007 BASS ENERGY CO INC 30329.00 67.00 365
2008 BASS ENERGY CO INC 27579.00 88.00 365
2009 BASS ENERGY CO INC 25716.00 41.00 365
2010 BASS ENERGY CO INC 23107.00 45.00 365
2011 BASS ENERGY CO INC 20757.00 0.00 0
2012 BASS ENERGY CO INC 21231.00 62.00 366
2013 BASS ENERGY CO INC 18171.00 0.00 365
2014 BASS ENERGY CO INC 12117.00 0.00 365
2015 BASS ENERGY CO INC 14232.00 65.00 365
2016 BASS ENERGY CO INC 15739.00 0.00 365
2017 BASS ENERGY CO INC 14781.00 0.00 365
2018 BASS ENERGY CO INC 13949.00 68.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 BASS ENERGY CO INC Brine 295 365
2006 BASS ENERGY CO INC Brine 145 365
2007 BASS ENERGY CO INC Brine 77 365
2008 BASS ENERGY CO INC Brine 3 365
2009 BASS ENERGY CO INC Brine 91 365
2010 BASS ENERGY CO INC Brine 105 365
2011 BASS ENERGY CO INC Brine 45
2012 BASS ENERGY CO INC Brine 70 366
2013 BASS ENERGY CO INC Brine 0 365
2014 BASS ENERGY CO INC Brine 30 365
2015 BASS ENERGY CO INC Brine 45 365
2016 BASS ENERGY CO INC Brine 81 365
2017 BASS ENERGY CO INC Brine 55 365
2018 BASS ENERGY CO INC Brine 50 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1077151688 2004-12-8 0:00: DD No Violations
-347879715 2011-12-22 0:00 UL No Violations 1.00
-606402332 2015-3-9 0:00:0 UP No Violations 0.50
0347879715 2011-12-22 UrbanPreliminary Restoration No Violations On 12/22/2011, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
0495614225 2014-10-09 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead is comprised of a mechanical plunger lift system in a board-on-board enclosure. Valves and connections are free from signs of leakage and appear functional. Areas surrounding the well area well maintained and free from signs of impact. The well is being returned to production following a shut-in period caused by on-going work with Dominion/East Ohio Gas distribution lines. Signage is present. The tank battery in a separate chain-link enclosure. The fittings and connections within the tank battery are free from leaks. The secondary containment is intact and the interior is free of signs of leaks, spills, or other problems. The load-outs are bull-plugged. The gate is secure.
0606402332 2015-03-09 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. Access to the well and battery are via the shared, asphalt-paved driveway which services the church and associated parking. The wellhead plunger lift and battery are in separate enclosures. At the time of my inspection, the enclosure gates are locked, load-outs are plugged, secure, and locked, and connections and fittings are secure and free from signs of leakage or other problems. The well and battery are located in an area which grades to the west, towards an unnamed stream. At the time of this inspection, the surrounding areas are snow-covered. I did not observe any signs of impact relating to the on-going production activity at the time of this inspection.
0734714820 2004-12-16 Drill / Deepen / Reopen No Violations moving rig to gates mills
1077151688 2004-12-08 Drill / Deepen / Reopen No Violations drilling (1200) picked up surface ticket which was set on 12/07/04 not witnessed because of IM training.
1324565064 2011-12-22 UrbanPreliminary Restoration No Violations Urban preliminary restoration inspection due. Inspection conducted and well is in compliance with 1501:9-9-05. Well passed.
1372859657 2013-07-03 UrbanPreliminary Restoration No Violations The producing unit consists of the following elements: a wellhead with mechanical plunger lift system and associated above-ground storage tank (AST) battery, which are both separately enclosed in and locked. The battery is comprised of 1 140-barrel and 1 50-barrel AST, mechanical separator, and Dominion metering run. Secondary containment is present and adequate. Loadouts are bull-headed and locked. Preliminary restoration passes.
1383331018 2017-11-30 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located on the front portion of a church property . At the time of this inspection, I found the following: a wellhead plunger-lift unit and associated battery in separate chain-link enclosures. The fittings and connections were secure and free from leakage or problems. Fittings and connections at the battery were secure. The load-lines were plugged and locked. ID signage was present and current. The secondary containment was intact with no signs of leakage, spills, or problems. The well was in active production. The chart recorder was active. Production reports and insurance were current.
495614225 2014-10-9 0:00: UP No Violations
734714820 2004-12-16 0:00 DD No Violations

For data sources see[9]

References