Well Status Well Status Date Comment
Changed to Orphan Well Pending 1997-05-01 Changed Well To Orphan Pending
APP 2002-09-20 Proposed Formations:OHIO SHALE, Issued Date:9/20/2002, Expired Date:9/20/2003 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged by Orphan Well Program 2002-10-16 Plugged by Orphan Well Program
Plugged/Abandoned 2002-10-16 RBDMS Rec
Construction Permit Expires 2003-09-20 RBDMS Rec
Record Last Modified 2019-06-05 RBDMS Rec

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1121814407 2005-07-07 Final Restoration No Violations approved
1298604103 2015-10-16 Orphan No Violations

-extent shallow soil punch-bar gas survey in selected areas of the yard, including the areas within and without the stressed portion of the yard. The results of this survey indicate gas readings of up to 100% LEL within the observed dead area. Readings outside of the dead area dropped to <10% LEL within several feet. The reported former location of well #2-1753 did not exhibit any surface expression of stressed vegetation or elevated gas readings. I observed a 6-inch diameter PVC pipe, located on the east side of the property. The pipe appears to extend several feet vertically into the subsurface. The top of the pipe is truncated, roughly, at grade and had been fitted with a slip-cap cover. The 6-inch pipe is immediately east of the dead spot. Beyond this feature to the east, I observed a 2-inch diameter PVC riser affixed to a sign post located in the Rustic Ln. tree lawn. Beyond the tree lawn, to the east, I observed a 30-inch diameter man-lid within the roadway. The location of the man-lid and vent correspond closely with the reported historic l