X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21655

Well Details

Well ID: 34-035-21655
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: ACACIA COUNTRY CLUB
License Status: Producing
License Date: 1998-04-27
Spud Date: 1998-05-02
Spud Drilling Contractor: MOHAWK DRLG
Final Drill Date: 1998-05-10
Well Total Depth: 3730.00 ft
Configuration: Directional
Latitude: 41.500000
Longitude: -81.480000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1998-04-27 Proposed Formations:CLINTON/NEWBURG/ORISKANY, Issued Date:4/27/98, Expired Date:4/27/99 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1998-05-02 RBDMS Rec
Completed 1998-05-10 RBDMS Rec
Reached Total Depth 1998-05-10 RBDMS Rec
Completion Report Received 1999-04-09 RBDMS Rec
Construction Permit Expires 1999-04-27 RBDMS Rec
Correction to Well 2001-02-02 CHANGE IN TARGET INFORMATION: FOOTAGE= 2030'NL & 202'EL OF LOT 81,TRACT 4; X= 2,277,008; AND Y= 670,732.
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-06-21 3516 3532 33
3516 3532 33
3516 3532 33

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 47000 Gal 70000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1999 BASS ENERGY CO INC 61526.00 190.00 301
2000 BASS ENERGY CO INC 62119.00 89.00 365
2001 BASS ENERGY CO INC 31579.00 49.00 365
2002 BASS ENERGY CO INC 20820.00 56.00 365
2003 BASS ENERGY CO INC 16611.00 44.00 365
2004 BASS ENERGY CO INC 14039.00 35.00 365
2005 BASS ENERGY CO INC 12235.00 37.00 365
2006 BASS ENERGY CO INC 8061.00 0.00 365
2007 BASS ENERGY CO INC 8544.00 0.00 365
2008 BASS ENERGY CO INC 7134.00 44.00 365
2009 BASS ENERGY CO INC 7579.00 0.00 365
2010 BASS ENERGY CO INC 7298.00 0.00 365
2011 BASS ENERGY CO INC 5794.00 0.00 0
2012 BASS ENERGY CO INC 5284.00 62.00 366
2013 BASS ENERGY CO INC 5452.00 0.00 365
2014 BASS ENERGY CO INC 5056.00 0.00 365
2015 BASS ENERGY CO INC 3765.00 20.00 365
2016 BASS ENERGY CO INC 2747.00 0.00 365
2017 BASS ENERGY CO INC 3747.00 0.00 365
2018 BASS ENERGY CO INC 3244.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1999 BASS ENERGY CO INC Brine 278 301
2000 BASS ENERGY CO INC Brine 257 365
2001 BASS ENERGY CO INC Brine 47 365
2002 BASS ENERGY CO INC Brine 103 365
2003 BASS ENERGY CO INC Brine 63 365
2004 BASS ENERGY CO INC Brine 32 365
2005 BASS ENERGY CO INC Brine 83 365
2006 BASS ENERGY CO INC Brine 0 365
2007 BASS ENERGY CO INC Brine 32 365
2008 BASS ENERGY CO INC Brine 1 365
2009 BASS ENERGY CO INC Brine 41 365
2010 BASS ENERGY CO INC Brine 38 365
2011 BASS ENERGY CO INC Brine 62
2012 BASS ENERGY CO INC Brine 0 366
2013 BASS ENERGY CO INC Brine 46 365
2014 BASS ENERGY CO INC Brine 37 365
2015 BASS ENERGY CO INC Brine 32 365
2016 BASS ENERGY CO INC Brine 22 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1207913318 2020-5-5 0:00:0 UP No Violations 1.00
-1892621267 2014-10-9 0:00: UP No Violations
-2011978219 2004-8-9 0:00:0 PL No Violations
0579787076 2017-08-16 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate enclosures located at the eastern fringe of park property, and adjacent to a newer condo development. The battery is shared with the #2-1656 well. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of managed turf grass and tall vegetation, with a short, gravel-paved access road. I did not observe any signs of problems.
1373642180 2012-10-23 UrbanProduction Wells No Violations My visit to this well was to perform an Urban Production well status check. This is a Rabbit well and the well head area is neat and clean with no evidence of leakage or overgrown vegetation. The well head is enclosed inside chain link fence and is secured with locks. The tank battery is enclosed in chain link fence and is secured with locks. There is one 140 BBL storage tank with secured caps and vents to include a charcoal filter. There is a vertical separator present and a metering run is present. There are pick up lines secured with bull head plugs and locks. There is one 50 BBL brine tank in good condition. No violations were noted and inspection passed.
1380300307 2013-09-27 UrbanProduction Wells No Violations The producing wellhead is fitted with a mechanical plunger lift and is located in a locked chain-link fence. The associated tank battery is comprised of 1 100-barrel steel production tank, 1 25-barrel poly brine tank, and separator. The battery is located in a separate chain-link enclosure. Load-outs are bull-plugged and locked. Secondary containment is good. The battery needs safety equipment (LPR valve, spark arrestor, carbon filter). I will discuss the missing items with Ralph Gregory of Bass Energy. The battery is shared with the #1656 unit.
1425864717 2015-03-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well is located along a private drive which is a newly constructed road adjacent to the former Acacia Country Club. The battery is located within the former Acacia Country Club grounds. The battery is shared with the #2-1656 well which is accessed from the same gated entry at Winchester. The wellhead mechanical plunger lift is located in a small board-on-board enclosure. Connections and fittings at the wellhead and the battery are secure and free from signs of leakage or problems. At the time of this inspection, the areas surrounding the well and battery are snow-covered. I did not observe any signs of impact relating to production activity.
1825538947 2017-11-30 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and battery are located on the grounds of a park property (former gold course), on the west side. The battery is shared with the #3 well located on the same parcel. At the time of this inspection, I found the following: a wellhead plunger-lift unit and associated battery in separate chain-link enclosures. The fittings and connections were secure and free from leakage or problems. Fittings and connections at the battery were secure. The load-lines were plugged and locked. ID signage was present and current. The secondary containment was intact with no signs of leakage, spills, or problems. The shared-use access road was in good condition. The well was in active production. The chart recorder was active. Production reports and insurance were current.
1892621267 2014-10-09 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The wellhead is comprised of a mechanical plunger lift system in a board-on-board enclosure. Valves and connections are free from signs of leakage and appear functional. Areas surrounding the well area well maintained and free from signs of impact. The well is producing and production reports are current. Signage is present. The tank battery in a separate chain-link enclosure. The fittings and connections within the tank battery are free from leaks. The secondary containment is intact and the interior is free of signs of leaks, spills, or other problems. The load-outs are bull-plugged. The gate is secure.
2011978219 2004-08-09 Preliminary Restoration No Violations
579787076 2017-8-16 0:00: UP No Violations 0.50

For data sources see[9]

References