X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21515

Well Details

Well ID: 34-035-21515
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: GREEN ENERGY INC
Well Pad ID:
Farm/Lease Name: GILMOUR ACADEMY
License Status: Producing
License Date: 1991-01-07
Spud Date: 1991-04-26
Spud Drilling Contractor: [[P&R INC [PEEK & ROWAN]]]
Final Drill Date: 1991-04-30
Well Total Depth: 3645.00 ft
Configuration: Vertical
Latitude: 41.500000
Longitude: -81.430000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1991-01-07 Issued Date 1/7/91 Expired Date 1/7/92 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03645 Proposed Drill Depth 03645
Original Spud 1991-04-25
Completed 1991-04-30
Reached Total Depth 1991-04-30
CO 1991-06-18 507 DOME DRILLING CO GeoDate 1/7/91
Completion Report Received 1991-09-26
Construction Permit Expires 1992-01-07
Change of Owner 2009-12-29 Operator changed from 507, DOME DRILLING CO to 1453, GREEN ENERGY INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3440 3520 0
3440 3520 0
2006-09-11 3473 3492 2
3473 3492 2
3440 3520 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 250 Lbs 0 WITH SURFACTANT, CLAY STABILIZER, FRICTION REDUCER & BACTERICIDE.
H2O 0 68590 Gal 40000 FRAC W/68,590 GAL WATER AND 400 SX

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 DOME DRILLING CO 4984.00 0.00 150
1992 DOME DRILLING CO 10236.00 0.00 365
1993 DOME DRILLING CO 16005.00 0.00 365
1994 DOME DRILLING CO 19846.00 65.00 365
1995 DOME DRILLING CO 33872.00 0.00 365
1996 DOME DRILLING CO 35324.00 144.00 365
1997 DOME DRILLING CO 48345.00 56.00 365
1998 DOME DRILLING CO 37508.00 0.00 365
1999 DOME DRILLING CO 19910.00 25.00 365
2000 DOME DRILLING CO 29515.00 0.00 365
2001 DOME DRILLING CO 22320.00 15.00 365
2002 DOME DRILLING CO 20341.00 0.00 365
2003 DOME DRILLING CO 24631.00 0.00 365
2004 DOME DRILLING CO 29216.00 0.00 365
2005 DOME DRILLING CO 17027.00 22.00 365
2006 DOME DRILLING CO 11826.00 0.00 365
2007 DOME DRILLING CO 9485.00 0.00 365
2008 DOME DRILLING CO 22454.00 36.00 365
2009 DOME DRILLING CO 11576.00 9.00 365
2010 GREEN ENERGY INC 5603.00 0.00 365
2011 GREEN ENERGY INC 4614.00 0.00 277
2012 GREEN ENERGY INC 361.00 0.00 245
2013 GREEN ENERGY INC 2666.00 0.00 365
2014 GREEN ENERGY INC 3177.00 0.00 365
2015 GREEN ENERGY INC 3823.00 0.00 365
2016 GREEN ENERGY INC 6926.00 0.00 365
2017 GREEN ENERGY INC 5706.00 38.00 365
2018 GREEN ENERGY INC 3270.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 DOME DRILLING CO Brine 0 150
1992 DOME DRILLING CO Brine 0 365
1993 DOME DRILLING CO Brine 0 365
1994 DOME DRILLING CO Brine 0 365
1995 DOME DRILLING CO Brine 0 365
1996 DOME DRILLING CO Brine 83 365
1997 DOME DRILLING CO Brine 45 365
1998 DOME DRILLING CO Brine 0 365
1999 DOME DRILLING CO Brine 0 365
2000 DOME DRILLING CO Brine 25 365
2001 DOME DRILLING CO Brine 56 365
2002 DOME DRILLING CO Brine 0 365
2003 DOME DRILLING CO Brine 45 365
2004 DOME DRILLING CO Brine 50 365
2005 DOME DRILLING CO Brine 0 365
2006 DOME DRILLING CO Brine 0 365
2007 DOME DRILLING CO Brine 0 365
2008 DOME DRILLING CO Brine 85 365
2009 DOME DRILLING CO Brine 0 365
2010 GREEN ENERGY INC Brine 160 365
2011 GREEN ENERGY INC Brine 110 277
2012 GREEN ENERGY INC Brine 2501 245
2013 GREEN ENERGY INC Brine 299 365
2014 GREEN ENERGY INC Brine 240 365
2015 GREEN ENERGY INC Brine 103 365
2016 GREEN ENERGY INC Brine 116 365
2017 GREEN ENERGY INC Brine 103 365
2018 GREEN ENERGY INC Brine 63 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1595570558 2010-12-1 0:00: PW No Violations
-1800556905 2010-11-16 0:00 PW No Violations
-204606736 2017-2-27 0:00: UP No Violations
-2144832614 2010-11-23 0:00 PW No Violations
-329108818 2010-12-9 0:00: PW No Violations
-484410016 2018-7-13 0:00: UP No Violations 1.00
-951029631 2010-11-10 0:00 PW No Violations
0204606736 2017-02-27 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and battery are located NW of the lower school parking area and are accessed via an unpaved maintenance drive which is shared with the school. The drive continues to the east and affords access to the #3 well (#2-1650), and well as other parts of the school grounds. The battery and wellhead are in separate chain-link enclosures which were locked and secure. The load-lines were locked. Secondary containment at the battery was present and intact and dry. Spark arrestor, charcoal filter, and sealing tank lids have been added since a previous inspection found these elements missing. The ID signage at the battery had been remedied and is satisfactory. Fittings and connections at the wellhead and battery are secure and free from signs of leakage or problems.
0329108818 2010-12-09 Production Wells No Violations All contaminated soil and gravel has been removed from site and new gravel replaced and oil storage tank has been reset.

Case closed

0484410016 2018-07-13 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The battery and wellhead are in separate chain-link enclosures which were locked and secure. The former plunger-lift system had been replaced with a pump jack. The well was in production. The fittings and connections were secure. The load-lines were locked. Secondary containment at the battery was present and intact and dry.
0509669623 2011-01-04 Production Wells No Violations Oil contaminated soil and gravel removed from site and disposed of, new gravel replace and tanks reset.
0951029631 2010-11-10 Production Wells Violations Noted Company called in to report a spill approximately 2 bbls of oil from oil storage tank that overflowed on Tuesday the 9th. The oil was contained inside the dike. I advised Mr.Gessle to cleanup oil remove fluids and remove gravel to landfill.

Will monitor site for final cleanup!

1369344899 2013-05-23 UrbanProduction Wells No Violations The producing unit consists of the following elements: a wellhead with pumpjack in a chain-link enclosure, and a tank battery system also in a chain-link enclosure. The enclosures are secured with locks and in in good condition. The tank battery is comprised of two 100-barrel steel tanks, and mechanical separator. Safety equipment is needed. I did not observe any other problems or violations. I contacted Jim with Green Energy and advised him that safety equipment would be needed within the next 30 days.
1374697512 2013-07-24 UrbanProduction Wells Violations Noted The producing unit consists of a wellhead with pumpjack unit and above-ground storage tank (AST) battery. The wellhead is located in a chain-link enclosure which is locked. The well is currently producing. There is no ID at the wellhead. I did not observe any signs of leakage or problems. The AST battery is comprised of one 140-barrel production tank, one 50-barrel brine tank, and mechanical separator in a chain-link enclosure. There is a unit ID at the wellhead. Secondary containment is good. The unit is lacking safety equipment in accordance with 1501:9-9-05E. I advised Green Energy that the ID and safety gear should be adressed before the start of school year.
1385920917 2013-11-22 UrbanProduction Wells Violations Noted Safety equipment has been added in accordance with 1501:9-0-05E. No problems noted
1459260727 2017-02-15 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following elements: a wellhead with pump jack system in a chain-link enclosure. The enclosure gate was locked and secure. Fittings and connections were secure. The associated battery was comprised of two 100-barrel steel tanks and separator unit in a separate chain-link enclosure. The enclosure gates were locked and secure. Load-line valves were plugged and locked. The secondary containment was intact. Production reports are current. I walked the area surrounding the well and battery and found it to be comprised of small deciduous trees, shrubs and wild vegetation with no evidence of drainage problems or signs of impacts relative to the on-going production activity. Access to the well and battery is afforded by a shared-use, gravel-paved access path which is maintained by the school facility and was in good condition.
1595570558 2010-12-01 Production Wells No Violations Site stable no off site run off.
1800556905 2010-11-16 Production Wells No Violations Company waiting on samples to be tested for disposal of gravel. All oily fluid has been removed from site. Company plans to set another 100 bbl tank in tank battery had to get approval from landowner.
2057777074 2003-09-25 Production Wells No Violations inspected well and tank battery. 210bbls, seperator, plastic brine.
2144832614 2010-11-23 Production Wells No Violations Called company to check cleanup. Dike still holding fluid no oil present on fluid. Company still waiting on test results for material to go to landfill.
509669623 2011-1-4 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0951029631 US-OH-130867 2010-11-30 Well operation causing pollution and contamination
1374697512 US-OH-111103 2013-07-25 ID (a-i)
1374697512 US-OH-111104 2013-07-25 TANKS (a-i)
1385920917 US-OH-111456 2016-07-26 9-05E5 OPERATIONMAINTANCE (a-c)

For data sources see[9]