If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-27225 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.3,"lon":-82.12,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Perry Township | |
Operator Name: NORTHWOOD ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: CARROLL TRUST | |
License Status: Producing | |
License Date: 2013-08-15 | |
Spud Date: 2014-03-28 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2014-04-01 | |
Well Total Depth: 3314.00 ft | |
Configuration: Vertical | |
Latitude: 40.300000 | |
Longitude: -82.120000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-08-15 | Proposed Formations:CLINTON, Issued Date:8/15/2013, Expired Date:8/15/2015 12:00:00 PM, Drilling unit acres:80.979, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2014-04-01 | |
Completion Report Received | 2015-06-02 | |
Construction Permit Expires | 2015-08-15 | |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | NORTHWOOD ENERGY CORP | 0.00 | 400.00 | 208 |
2015 | NORTHWOOD ENERGY CORP | 0.00 | 307.00 | 365 |
2016 | NORTHWOOD ENERGY CORP | 0.00 | 116.00 | 365 |
2017 | NORTHWOOD ENERGY CORP | 0.00 | 114.00 | 365 |
2018 | NORTHWOOD ENERGY CORP | 0.00 | 60.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | NORTHWOOD ENERGY CORP | Brine | 240 | 208 |
2015 | NORTHWOOD ENERGY CORP | Brine | 231 | 365 |
2016 | NORTHWOOD ENERGY CORP | Brine | 136 | 365 |
2017 | NORTHWOOD ENERGY CORP | Brine | 0 | 365 |
2018 | NORTHWOOD ENERGY CORP | Brine | 79 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1327878586 | 2015-9-4 0:00:0 | PW | No Violations | |
-1349208064 | 2014-4-7 0:00:0 | DD | No Violations | |
-1391726164 | 2018-1-3 0:00:0 | PW | No Violations | 0.50 |
-814289761 | 2014-6-27 0:00: | PL | No Violations | |
-986251293 | 2016-11-28 0:00 | PW | No Violations | 0.50 |
0661550281 | 2014-04-01 | Casing String Witnessed | No Violations | On the day of my inspection I found that Poulson Drilling had drilled a 7.875 production hole on air to 3314. They ran 3258 of used tested 4.5 casing. Petroset cemented the casing with 175 sacks of class A cement. |
0814289761 | 2014-06-27 | Preliminary Restoration | No Violations | On the day of my inspection I found that the trailer and equipment had been removed from the location. The entire drill site was growing in agricultural crops. I found no signs of erosion or sedimentation. This site passes preliminary restoration. |
0911864014 | 2014-03-26 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I found that the location was cut and the apron was stoned. There were no drilling pits dug yet. I contacted Corey of Northwood Energy to request that they install silt fence along the south edge of the location in order to protect the nearby intermittent stream from potential runoff and/or sedimentation. |
0986251293 | 2016-11-28 | Production Wells | No Violations | On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor and drive belts were intact. The electric was connected at the box and to the motor. The flow lines were connected at the wellhead. The tubing and casing valves were open. The tank battery consisted of two 100 barrel steel tanks, a 10 barrel water knock-out tank and a horizontal separator. There was an earthen dike in place around the production equipment. There was a 1 inch plastic line from the separator to a burning flare stack. Correct, legible identification was posted and I found no leaks or spills. |
1314428500 | 2014-03-28 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I found that the Poulson Drilling was rigged up and drilling the conductor hole on fluid. Silt fence was installed at the south end of the location. The pits were lined. The permit was posted in the doghouse. I found no leaks or spills around the drill site. |
1327878586 | 2015-09-04 | Production Wells | No Violations | On the day of my inspection I found that the wellhead was equipped with a pumping unit. The valves were open and the unit was in operation. The tank battery consisted of two 100 barrel tanks, one separator and an earthen dike. Identification was posted. This well is connected to a flare stack because Northwood does not have the infrastructure in place to sell gas. The flare was out at the time of my inspection. I called Mark Fluharty and he came out to re-light the flare. |
1347449385 | 2014-03-31 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I found that Poulson Drilling was drilling on air at a depth of 2819. The blow pit was close to running over. I contacted Corey McCudden of Northwood Energy to request that he get a water truck out as soon as possible to remove some of the fluid in the pit. The permit was posted and I found no leaks or spills. |
1349208064 | 2014-04-07 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I found that the pits were closed. This violation is resolved. |
1391726164 | 2018-01-03 | Production Wells | No Violations | On the day of my inspection I found that the well was equipped with an electric powered pumping unit. The motor, drive belts and electric were intact. The flow lines were connected at the wellhead and the valves were open. There were no leaks around the wellhead. There was a flare stack approximately 75 feet from the wellhead that was burning. The production equipment consisted of two 100 barrel steel tanks and one horizontal separator in an earthen dike. Correct, legible identification was posted and I found no leaks or spills around the tanks. |
1396031103 | 2014-03-28 | Casing String Witnessed | No Violations | On the day of my inspection I found that Poulson Drilling had drilled a 14.75 conductor hole to a depth of 89. They ran 84 of new 11.75 casing. Petroset broke circulation and cemented the casing to surface with 125 sacks of class A cement. Good circulation was maintained throughout the job with approximately 9 barrels of cement returns. |
1396276168 | 2014-03-29 | Casing String Witnessed | No Violations | On the day of my inspection I found that Poulson Drilling had drilled an 11 surface hole to a depth of 373. They ran 348 of new 11.75 casing. Petroset broke circulation and cemented the casing to surface with 160 sacks of class A cement. Good circulation was maintained throughout the job with approximately 7 barrels of cement returns. |
1396528592 | 2014-04-03 | Drill / Deepen / Reopen | Violations Noted | On the day of my inspection I found that the fluid level in the back pit was breeching the walls. The front pit was missing half of the liner. I contacted Corey McCudden of Northwood Energy to request that they address the pits immediately. He claimed that they were working on them all day yesterday and they would be back to try and finish them up today. |
1443011969 | 2014-06-05 | Preliminary Restoration | No Violations | On the day of my inspection I found that the pits were closed. The drilling equipment and materials had been removed and the location was graded out. The well was equipped with a pumping unit. The tank battery was diked. The well site is in agricultural field and therefore will not require grass seed. The field was plowed and planted. There were two pieces of excavating equipment and a trailer left on location. This site will pass preliminary restoration when the equipment is removed and there is some crop growth for erosion control. |
1543524785 | 2018-11-29 | Production Wells | No Violations | On the day of my inspection I found that there were no leaks or spills around the pumping unit or tanks. The lines were connected, and the valves were open. Correct, legible identification was posted, and the flare stack was burning. |
40417486 | 2020-2-21 0:00: | PW | No Violations | 0.50 |
661550281 | 2014-4-1 0:00:0 | CS | No Violations | |
911864014 | 2014-3-26 0:00: | DD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1396528592 | US-OH-111732 | 2015-01-08 | Drilling operation causing pollution and contamination |
For data sources see[7]