34-031-23538

Well Details

Well ID: 34-031-23538
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Jefferson Township
Operator Name: KMFAD OIL AND GAS LLC
Well Pad ID:
Farm/Lease Name: BAKER RT
License Status: Producing
License Date: 1979-05-31
Spud Date: 1979-09-20
Spud Drilling Contractor:
Final Drill Date: 1979-10-26
Well Total Depth: 3677.00 ft
Configuration: Vertical
Latitude: 40.360000
Longitude: -82.000000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-05-31 124 MOORE JERRY INC GeoDate 5/31/79
Original Spud 1979-09-20
Completed 1979-10-26
Reached Total Depth 1979-10-26
Change of Owner 2003-03-06 Operator changed from 124, MOORE JERRY INC to 7404, A S N F PRODUCING INC
Change of Owner 2014-08-19 Operator changed from 7404, A S N F PRODUCING INC to 9316, KMFAD OIL AND GAS LLC
Record Last Modified 2019-06-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3534 3590 32
3534 3590 32
3534 3590 32

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 100 0 SCF/BBL.
H2O 0 33000 Gal 47000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 JERRY MOORE INC 9362.00 319.00 0
1985 JERRY MOORE INC 9716.00 422.00 0
1986 JERRY MOORE INC 5800.00 195.00 365
1987 JERRY MOORE INC 5097.00 200.00 365
1988 JERRY MOORE INC 4112.00 99.00 365
1989 JERRY MOORE INC 4723.00 198.00 365
1990 JERRY MOORE INC 3981.00 135.00 365
1991 JERRY MOORE INC 1082.00 62.00 365
1992 JERRY MOORE INC 2131.00 69.00 365
1993 JERRY MOORE INC 1104.00 9.00 365
1994 JERRY MOORE INC 1400.00 139.00 365
1995 JERRY MOORE INC 1039.00 186.00 365
1996 JERRY MOORE INC 1146.00 73.00 365
1997 JERRY MOORE INC 1514.00 145.00 365
1998 JERRY MOORE INC 110.00 0.00 365
1999 JERRY MOORE INC 540.00 78.00 365
2000 JERRY MOORE INC 290.00 15.00 365
2001 JERRY MOORE INC 273.00 38.00 365
2002 JERRY MOORE INC 98.00 0.00 365
2003 JERRY MOORE INC 0.00 0.00 365
2004 A S N F PRODUCING INC 147.00 0.00 365
2005 A S N F PRODUCING INC 213.00 100.00 365
2006 A S N F PRODUCING INC 129.00 0.00 365
2007 A S N F PRODUCING INC 69.00 55.00 365
2008 A S N F PRODUCING INC 39.00 42.00 365
2009 A S N F PRODUCING INC 46.00 46.00 365
2010 A S N F PRODUCING INC 44.00 104.00 365
2011 A S N F PRODUCING INC 0.00 29.00 365
2012 A S N F PRODUCING INC 0.00 50.00 366
2013 A S N F PRODUCING INC 0.00 32.00 365
2014 KMFAD OIL AND GAS LLC 0.00 17.00 0
2015 KMFAD OIL AND GAS LLC 0.00 24.00 365
2016 KMFAD OIL AND GAS LLC 0.00 60.00 365
2017 KMFAD OIL AND GAS LLC 0.00 32.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 JERRY MOORE INC Brine 0 0
1985 JERRY MOORE INC Brine 0 0
1986 JERRY MOORE INC Brine 0 365
1987 JERRY MOORE INC Brine 0 365
1988 JERRY MOORE INC Brine 0 365
1989 JERRY MOORE INC Brine 0 365
1990 JERRY MOORE INC Brine 0 365
1991 JERRY MOORE INC Brine 0 365
1992 JERRY MOORE INC Brine 0 365
1993 JERRY MOORE INC Brine 0 365
1994 JERRY MOORE INC Brine 0 365
1995 JERRY MOORE INC Brine 0 365
1996 JERRY MOORE INC Brine 0 365
1997 JERRY MOORE INC Brine 0 365
1998 JERRY MOORE INC Brine 0 365
1999 JERRY MOORE INC Brine 0 365
2000 JERRY MOORE INC Brine 0 365
2001 JERRY MOORE INC Brine 0 365
2002 JERRY MOORE INC Brine 0 365
2003 JERRY MOORE INC Brine 0 365
2004 A S N F PRODUCING INC Brine 0 365
2005 A S N F PRODUCING INC Brine 0 365
2006 A S N F PRODUCING INC Brine 0 365
2007 A S N F PRODUCING INC Brine 0 365
2008 A S N F PRODUCING INC Brine 0 365
2009 A S N F PRODUCING INC Brine 0 365
2010 A S N F PRODUCING INC Brine 0 365
2011 A S N F PRODUCING INC Brine 25 365
2012 A S N F PRODUCING INC Brine 30 366
2013 A S N F PRODUCING INC Brine 45 365
2014 KMFAD OIL AND GAS LLC Brine 0 0
2015 KMFAD OIL AND GAS LLC Brine 0 365
2016 KMFAD OIL AND GAS LLC Brine 0 365
2017 KMFAD OIL AND GAS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1071136502 2020-8-4 0:00:0 PW No Violations 0.50
-1151404228 2020-10-13 0:00 PW No Violations 0.50
-1637251812 2020-10-23 0:00 PW No Violations 0.50
-1656360703 2010-11-12 0:00 PW No Violations
-2023260530 2020-7-23 0:00: PW No Violations 1.00
-2099358367 2016-9-6 0:00:0 PW No Violations 2.50
-305475466 2019-4-29 0:00: PW No Violations 1.00
0171665120 2016-08-30 Administrative Inspection No Violations I received a phone call from landowner David Wigginson, who left a voice message claiming that he found a leak in the flow line from the wellhead to the tank battery. In the message Mr. Wigginson claimed that there was a hole full of oil and it was bubbling gas. I tried to call Mr. Wigginson multiple times and I could not get an answer. I left him a message to contact me at his earliest convenience. I called Mike Ingalls and Carrie Moore with KMFAD. Mike said that they did have a leak in the flow line and he had been out to make the repair. He dug the soil out around the leak to access the line. Mike said that he had the wrong size line clamp and he was on his way back out with the correct clamp. He claimed that the well had been shut in since the leak was discovered, thereby disputing Mr. Wigginsons claim of bubbling gas. Mike also disputed the claim that the hole was full of oil. He said that there had been a small amount of oil from the initial discovery of the leak, and the hole was full of water from recent rain. Carrie Moore sent me photographs of the hole to show that it was not full of oil. Mr. Wigginson finally called me back. He admitted that the excavated hole had been covered with piece of metal and since he only lifted the corner of the metal, that the fluid in the hole might have been rain water with a skim of oil on top. I told him that I had spoken to Mike Ingalls, and he was allegedly on his way out to finish the repair and clean up any oil. I was on sick leave at the time of the call. I asked Mr. Wigginson if I needed to send someone out. He sad that there was no need and he did not want to file an official complaint. He also claimed that he had a problem with an area in his hayfield that had been excavated by KMFAD for flow line repairs. He said that the soil had sunken down 7 or 8 inches, causing problems with his machinery when he mows hay. I told Mr. Wigginson that I would be out to follow up on September 6.
0305475466 2019-04-29 Production Wells No Violations On the day of my inspection I met Mr. Wigginson at the well site. He said that Carrie had been out last week to start laying a new line, but she did not finish and hasnt been back. There was a ditch started at the wellhead, and there was a 2 inch diameter plastic line plumbed into the steel flow line at the wellhead. The line was not buried and it was not connected at the separator. There was oil laying on the water that had collected in the ditch. The oil in the grass from the original leak had not been cleaned up yet either. I tried to call Carrie Moore and she did not answer. I left a voice message.
0341165876 2019-05-09 Production Wells No Violations On the day of my inspection I found that Carrie Moore had the new flow line buried from the wellhead to the separator. The ditch line was rough, but Mr. Wigginson said that he was going to disk the entire area as soon as it dries out a little. There was still some oily peat left on the grass where the old line had leaked. Mr. Wigginson said that he was going to spread some fertilizer on it and disk it in with the rest of the soil. He said that he was satisfied with what was done, and he would call me if he had any more issues. This compliance notice is resolved.
1289573632 2010-11-12 Production Wells Violations Noted Meet with Mr. Wiggington ( Landowner ) at well site, well head is leaking gas from annulus of production casing. Well head is equipped with a casing hanger, there is no way to shut well annulus in to stop gas from leaking. Checked area with gas detector a
1291050110 2010-11-29 Production Wells No Violations Follow up complaint of gas venting at well head. Meet with Landowner Mr. Wigginton at well site, notified him that well was in compliance with 1501:9-9-05 B. Well head has been welded up and a 1 shut off and Pop off instaled at well head. 1 steel line running from pop off to storage tank, gas is beening vented into storgae tank.
1434295389 2019-05-02 Production Wells No Violations On the day of my inspection I found that Carrie Moore was at the site working on the new flow line. The line had been properly tied in at the wellhead, and the oil that I found in the ditch was cleaned up. She still needed another section of steel line to tie in with the separator. She also still needed to get the oil cleaned up that was in the grass where the old linen had leaked. Carrie claimed that she would have the line all tied in today and then she wanted to pressure test the whole line before burying it.
1465604345 2020-8-26 0:00: PW No Violations 0.50
1656360703 2010-11-12 Production Wells Violations Noted Well head is to be constructed to prevent gas from venting into the atmosphere.
171665120 2016-8-30 0:00: AM No Violations 2.00
1901843030 2020-7-31 0:00: PW No Violations 0.30
1993161577 2019-04-16 Production Wells Violations Noted I received a phone call from landowner David Wigginson to report a leak between the pumping unit and the production tank. I met Mr. Wigginson at the site and he showed me the area of concern. There was an area approximately 3 x 5 feet that was laying wet with oil and water. Natural gas was bubbling up through the fluid. KMFAD had a similar incident in the same spot in August of 2016. I tried to call Carrie Moore and she did not answer. The voice mail was full, so I couldnt leave a message. I sent her a text message and she finally responded at 05:47 on 4/17/19. There was also a gas leak from one of the fittings on the production equipment. Mr. Wigginson said that his pressures have been unusually high. He said that he has always been maintained around 20 pounds, but he has noticed pressures up to 100 pounds recently. The gauge on the separator showed 70 pounds. The well owner shall complete the following actions within 5 days of the receipt of this compliance notice: (1) Identify and address the cause of the system becoming over pressurized. (2) Tighten the fitting at the separator to prevent the escape of gas. (3) Remove the oil contaminated soil from the area where the flow line is leaking. (4) Replace or repair the section of flow line that is failing.
2099358367 2016-09-06 Production Wells No Violations On the day of my inspection I met landowner David Wigginson at the well site. The well was being produced with an electric powered pumping unit. The unit was in operation at the time of inspection. The tank battery consisted of one 100 barrel steel tank and one horizontal separator. There was no dike around the production equipment. Correct, legible identification was posted on the tank. There were no leaks or spills around the tank battery. There were no active leaks at the wellhead. There was a four foot area of oil stained soil around the wellhead that had been stirred up and covered with mulch. Mr. Wigginson said that the stuffing box had a history of leaking. The area where the flow line had been repaired was covered with soil. I did no observe any oil staining in the soil. Mr. Wigginson showed me the disturbed area in the hayfield that he wants restored. It was rough and covered in weeds rather that hayfield vegetation. I told Mr. Wigginson that I would contact KMFAD and talk to them about restoring the area in the hayfield, and I would have them clean up the oil stained soil around the wellhead. I called Mike Ingalls with KMFAD to tell him that they needed to either remove the oil stained soil around the wellhead, or treat it with lime and fertilizer. I also asked about the disturbed area in the hayfield. He said that they were ready to go in and complete the restoration, and he would call me when they were done with everything.
222021188 2020-9-25 0:00: PW No Violations 0.30
341165876 2019-5-9 0:00:0 PW No Violations 0.70
503656117 2020-7-28 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1289573632 US-OH-108170 2010-11-12 Unlawful venting or flaring of gas
1656360703 US-OH-116352 2010-11-12 Unlawful venting or flaring of gas
1993161577 US-OH-120219 2019-05-31 9-10-04 Inadequate pipeline strength
1993161577 US-OH-120220 2019-05-31 9-1-07 Well operation causing pollution and contamination
1993161577 US-OH-120221 2019-05-31 9-9-02 General Safety

For data sources see[9]