X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-21665

Well Details

Well ID: 34-029-21665
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Hanover Township
Operator Name: VANGUARD OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: STAMP
License Status: Producing
License Date: 2008-07-09
Spud Date: 2008-09-26
Spud Drilling Contractor: BIG SKY ENERGY INC.
Final Drill Date: 2008-10-12
Well Total Depth: 6075.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -80.890000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-09 Proposed Formations:CLINTON, Issued Date:7/9/2008, Expired Date:7/9/2009 6:00:00 AM, Drilling unit acres:40.19, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-12
Construction Permit Expires 2009-07-09
Completion Report Received 2009-10-13
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-11-13 5788 5919 204
5788 5919 204
5788 5919 204

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 114715 Gal 55000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 VANGUARD OIL & GAS LLC 2850.00 0.00 120
2010 VANGUARD OIL & GAS LLC 13934.00 0.00 365
2011 VANGUARD OIL & GAS LLC 10654.00 0.00 0
2012 VANGUARD OIL & GAS LLC 10558.00 0.00 366
2013 VANGUARD OIL & GAS LLC 4882.00 0.00 365
2014 VANGUARD OIL & GAS LLC 6609.00 0.00 365
2015 VANGUARD OIL & GAS LLC 5377.00 0.00 365
2016 VANGUARD OIL & GAS LLC 3057.00 0.00 365
2017 VANGUARD OIL & GAS LLC 2579.00 0.00 365
2018 VANGUARD OIL & GAS LLC 2994.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 VANGUARD OIL & GAS LLC Brine 280 120
2010 VANGUARD OIL & GAS LLC Brine 230 365
2011 VANGUARD OIL & GAS LLC Brine 65
2012 VANGUARD OIL & GAS LLC Brine 135 366
2013 VANGUARD OIL & GAS LLC Brine 0 365
2014 VANGUARD OIL & GAS LLC Brine 110 365
2015 VANGUARD OIL & GAS LLC Brine 0 365
2016 VANGUARD OIL & GAS LLC Brine 50 365
2017 VANGUARD OIL & GAS LLC Brine 0 365
2018 VANGUARD OIL & GAS LLC Brine 60 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1092187348 2009-5-4 0:00:0 DD No Violations 1.00
-115099305 2008-10-5 0:00: DD No Violations 1.50
-123830950 2008-10-8 0:00: DD No Violations 0.50
-1662245138 2014-10-22 0:00 PW No Violations
-1687979071 2014-10-22 0:00 PL No Violations
-448315132 2008-9-23 0:00: DD No Violations 0.50
-947248762 2017-12-11 0:00 PW No Violations 0.40
0115099305 2008-10-05 Drill / Deepen / Reopen No Violations Inspection revealed that Big Sky Drilling is making a bit trip. No violations at this time.
0123830950 2008-10-08 Drill / Deepen / Reopen No Violations Inspection revealed that Big Sky Drilling has moved off location. No violations at this time.
0448315132 2008-09-23 Drill / Deepen / Reopen No Violations Inspection revealed that the location has been built . This is suppose to be Big Sky Drillings next location ( rig not on site at this time) . No violations at this time.
0947248762 2017-12-11 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1665. RBDMS indicated production was current. Lease access and the well and tank battery locations were stable. The well head was protected by a perimeter of livestock gates. Correct identification was present at the tank battery. The 8.625 well head was below grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A domestic supply connection was present. The tank battery was shared with 2-1685. A stable earthen dike that was free of fluid was present around the production equipment. Equipment within the dike consisted of one (1) horizontal separator and one (1) 100 bbl production tank. The separator remained in good repair and contained a current 7 day production chart. The production tank remained in good repair. Valves were closed and plugged. No violations were observed during this inspection.
1092187348 2009-05-04 Drill / Deepen / Reopen No Violations Inspection revealed no violations at this time.
1139977539 2008-10-02 Drill / Deepen / Reopen No Violations Inspection revealed that Big Sky drilling is at 5081 . No violations at this time.
1662245138 2014-10-22 Production Wells No Violations I was on site to conduct a status check. The tank battery is shared between #21665 (Stamp #1) and #21685 (Stamp #2). Identification was posted on the tank battery but missing permit number. The tank battery consists of one 100 bbl production tank, no brine tank, and one horizontal and one vertical separator. The tank valves are plugged. There is one meter box with a current chart showing production. Gas is leaking from the copper line going to the meter box. A dike is present and in good repair. The wellhead is equipped as a plunger lift with a domestic supply line. The access road and site are stable. The owner will be contacted regarding the identification and gas leak at the meter box.
1687979071 2014-10-22 Preliminary Restoration No Violations I was on site to assess the completion of preliminary restoration. All drilling equipment has been removed and production equipment is in place. The tank battery is shared between #21665 (Stamp #1) and #21685 (Stamp #2). Identification was posted on the tank battery. The tank battery consists of one 100 bbl production tank, no brine tank, and one horizontal and one vertical separator. The tank valves are plugged. There is one meter box with a current chart showing production. A dike is present and in good repair. The wellhead is equipped as a plunger lift with a domestic supply line. Vegetation is growing on all disturbed surfaces. The access road and site are stable. Preliminary restoration is complete and approved.
1702800411 2014-10-22 Preliminary Restoration No Violations I was on site to assess the completion of preliminary restoration. All drilling equipment has been removed and production equipment is in place. The tank battery is shared between #21665 (Stamp #1) and #21685 (Stamp #2). Identification was posted on the tank battery. The tank battery consists of one 100 bbl production tank, no brine tank, and one horizontal and one vertical separator. The tank valves are plugged. There is one meter box with a current chart showing production. A dike is present and in good repair. The wellhead is equipped as a plunger lift with a domestic supply. Vegetation is growing on all disturbed surfaces. The access road and site are stable. Preliminary restoration is complete and approved.

For data sources see[9]

References