X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-21087

Well Details

Well ID: 34-029-21087
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: West Township
Operator Name: QUALITY OIL & GAS CORP
Well Pad ID:
Farm/Lease Name: SANOR G
License Status: Producing
License Date: 1984-10-15
Spud Date: 1984-10-26
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1984-11-09
Well Total Depth: 5464.00 ft
Configuration: Vertical
Latitude: 40.810000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-10-15 648 QUALITY OIL & GAS GeoDate 10/15/84
Oil and Gas 1984-10-15 Issued Date 10/15/84 Expired Date 4/13/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05464 Proposed Drill Depth 05464
Original Spud 1984-10-26
Completed 1984-11-09
Reached Total Depth 1984-11-09
Completion Report Received 1984-11-27
Construction Permit Expires 1985-04-13
Last Compliance Report 2016-11-10
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5233 5340 0
5233 5340 0
2006-09-11 5279 5338 42
5279 5338 42
5233 5340 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 145000 Gal 114000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 QUALITY OIL & GAS CORP 5441.00 355.00 365
1994 QUALITY OIL & GAS CORP 4495.00 253.00 365
1995 QUALITY OIL & GAS CORP 5620.00 300.00 365
1997 QUALITY OIL & GAS CORP 4737.00 198.00 364
1998 QUALITY OIL & GAS CORP 3458.00 204.00 365
2000 QUALITY OIL & GAS CORP 2832.00 281.00 365
2001 QUALITY OIL & GAS CORP 3048.00 126.00 365
2002 QUALITY OIL & GAS CORP 2927.00 307.00 365
2003 QUALITY OIL & GAS CORP 2232.00 126.00 365
2004 QUALITY OIL & GAS CORP 1667.00 198.00 365
2005 QUALITY OIL & GAS CORP 2712.00 122.00 365
2006 QUALITY OIL & GAS CORP 2902.00 155.00 365
2007 QUALITY OIL & GAS CORP 3313.00 147.00 365
2008 QUALITY OIL & GAS CORP 3378.00 0.00 365
2009 QUALITY OIL & GAS CORP 2108.00 158.00 365
2010 QUALITY OIL & GAS CORP 2087.00 0.00 365
2011 QUALITY OIL & GAS CORP 1611.00 149.00 365
2012 QUALITY OIL & GAS CORP 1481.00 121.00 366
2013 QUALITY OIL & GAS CORP 2337.00 217.00 365
2014 QUALITY OIL & GAS CORP 1958.00 101.00 365
2015 QUALITY OIL & GAS CORP 2014.00 213.00 365
2016 QUALITY OIL & GAS CORP 1390.00 143.00 365
2017 QUALITY OIL & GAS CORP 1508.00 133.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 QUALITY OIL & GAS CORP Brine 85 365
1994 QUALITY OIL & GAS CORP Brine 30 365
1995 QUALITY OIL & GAS CORP Brine 187 365
1997 QUALITY OIL & GAS CORP Brine 82 364
1998 QUALITY OIL & GAS CORP Brine 135 365
2000 QUALITY OIL & GAS CORP Brine 70 365
2001 QUALITY OIL & GAS CORP Brine 75 365
2002 QUALITY OIL & GAS CORP Brine 25 365
2003 QUALITY OIL & GAS CORP Brine 0 365
2004 QUALITY OIL & GAS CORP Brine 20 365
2005 QUALITY OIL & GAS CORP Brine 50 365
2006 QUALITY OIL & GAS CORP Brine 45 365
2007 QUALITY OIL & GAS CORP Brine 45 365
2008 QUALITY OIL & GAS CORP Brine 0 365
2009 QUALITY OIL & GAS CORP Brine 30 365
2010 QUALITY OIL & GAS CORP Brine 0 365
2011 QUALITY OIL & GAS CORP Brine 0 365
2012 QUALITY OIL & GAS CORP Brine 0 366
2013 QUALITY OIL & GAS CORP Brine 0 365
2014 QUALITY OIL & GAS CORP Brine 0 365
2015 QUALITY OIL & GAS CORP Brine 25 365
2016 QUALITY OIL & GAS CORP Brine 0 365
2017 QUALITY OIL & GAS CORP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1595193942 2020-1-8 0:00:0 PW No Violations 1.00
-1662571030 2016-9-9 0:00:0 PW No Violations
-1833290989 2016-11-3 0:00: PW No Violations
-275092388 2005-11-21 0:00 AD No Violations 0.50
-925330191 2016-8-24 0:00: TD No Violations
-9711073 2016-8-24 0:00: PW No Violations
0009711073 2016-08-24 Production Wells No Violations On August 24, 2016 I conducted a status check inspection of the G. Sanor #1. RBDMS shows the operator has reported production within the last two years. The lease road to the well and tank battery is stable and in good repair. The well site is stable with well--tube assembly causing contamination to the ground around the well head. The area of disturbance is approximately four (4) feet in diameter. A domestic supply connection was also present. The tank battery was enclosed by an earthen dike that was insufficient in capacity to contain a production release in the event of equipment failure. The tank battery is upgrade and within close proximity to the headwaters of the Middle Branch Sandy Creek. The production equipment within the dike consisted of one (1) horizontal separator, one (1) 210 bbl production tank and one (1) buried brine vault. Minimum spacing requirements are met. The separator was in good repair. No audible or visual leaks were detected. A current 7 day chart was in the meter house. The production tank was leaking production from several small holes in the tank body. Correct, legible and conspicuous identification was present. The load line valve was closed and plugged. The brine drain valve was in the closed position and plumbed to the vault. The brine tank remained in good repair and was holding fluid. No evidence of overfilling existed. I will contact Quality Oil & Gas Corp. to have the well head leak repaired, clean up the contaminated area, and make repairs to the production tank body leaks.
0275092388 2005-11-21 Annular Disposal No Violations The AD is not hooked up and not in use.
0925330191 2016-08-24 Temporary Abandoned Annular Disposal No Violations Annular disposal was not connected at time of inspection.
0953755959 2005-02-10 Production Wells No Violations The tank battery consists of 1-210 bbl storage tank, 1-buried concrete salt water tank, 1-separator and a dike.
1098707454 2016-08-24 Production Wells No Violations The purpose of my inspection was to conduct a status check of the G. Sanor #1 (#2-1087). RBDMS shows the operator has reported production within the last two years. The lease road to the well and tank battery is stable and in good repair. The well site is stable with well--tube assembly causing contamination to the ground around the well head. The area of disturbance is approximately four (4) feet in diameter. A domestic supply connection was also present. The tank battery was enclosed by an earthen dike that was insufficient in capacity to contain a production release in the event of equipment failure. The tank battery is upgrade and within close proximity to the headwaters of the Middle Branch Sandy Creek. The production equipment within the dike consisted of one (1) horizontal separator, one (1) 210 bbl production tank and one (1) buried brine vault. Minimum spacing requirements are met. The separator was in good repair. No audible or visual leaks were detected. A current 7 day chart was in the meter house. The production tank was leaking production from several small holes in the tank body. Correct, legible and conspicuous identification was present. The load line valve was closed and plugged. The brine drain valve was in the closed position and plumbed to the vault. The brine tank remained in good repair and was holding fluid. No evidence of overfilling existed. I will contact Cathy at Quality Oil & Gas Corp. to have the well head leak repaired, clean up the contaminated area, and make repairs to the production tank body leaks.
1662571030 2016-09-09 Production Wells No Violations Cathy from Quality Oil & Gas Corp. returned my voicemail from September 8, 2016. I communicated the issues I observed during my inspection on August 24, 2016. Cathy took note of the issues and informed me that she would communicate my concerns to Dave Wittick, contract lease operator for Quality. Further, Cathy would have Mr. Wittick contact me once the repairs were completed in order to conduct a follow-up inspection.
1746952342 2016-09-26 Production Wells No Violations The purpose of my inspection was to follow-up on non-compliance issues I observed during my status check inspection on 8/24/2016. Contract lease operator Dave Wittick was on location during the inspection. During my inspection on 8/24/2016, I observed production fluids leaking from well head plumbing connections, ground contamination from the well head leaks, production fluid leaking from holes in the production tank body and an insufficient dike. During the follow-up inspection, I observed the connections that were previously in poor repair to have been repaired. The contaminated surface area below the well head was cleaned up. The upper hammer union connection on the U-tube assembly was observed dripping production fluid (brine) to the ground surface. Mr. Wittick acknowledged the leak and informed me that he would schedule a plumber out to repair the leak within the week. Concerning the tank battery, Mr. Wittick informed me that the production tank was no longer serviceable and was scheduled for replacement within the week. Following replacement, the earthen dike would be repaired and made sufficient for containment.
1833290989 2016-11-03 Production Wells No Violations The purpose for my inspection was to follow up on work performed to repair a leaking well head flow line connection, improve an insufficient dike and repair leaks detected on the production tank body. The Operator has repaired the leaks to the flow line at the well head. No audible or visual leaks were detected. The earthen dike wall has been improved to sufficiently contain a release. A replacement production tank has been placed within the dike. Correct and legible identification is conspicuously on the tank body. No further action is necessary.
953755959 2005-2-10 0:00: PW No Violations 0.50

For data sources see[9]

References