34-029-21075

Well Details

Well ID: 34-029-21075
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Butler Township
Operator Name: VANGUARD OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: ALEXANDER WM
License Status: Producing
License Date: 1985-10-29
Spud Date: 1986-01-21
Spud Drilling Contractor: CHM DRLG
Final Drill Date: 1986-02-09
Well Total Depth: 5886.00 ft
Configuration: Vertical
Latitude: 40.840000
Longitude: -80.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-10-02 Issued Date 10/2/84 Expired Date 3/31/85 Acres 0121420 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1985-10-29 457 ALSID OIL & GAS GeoDate 10/29/85
Oil and Gas 1985-10-29 Issued Date 10/29/85 Expired Date 10/29/86 Acres 0121420 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05886 Proposed Drill Depth 05886
Original Spud 1986-01-21 CHG FTG 02/09/1985 & 12/30/84, RI 11/2/85
Completed 1986-02-09 CHG FTG 02/09/1985 & 12/30/84, RI 11/2/85
Reached Total Depth 1986-02-09 CHG FTG 02/09/1985 & 12/30/84, RI 11/2/85
CO 1986-02-11 457 ALSID OIL & GAS GeoDate 10/2/84
Completion Report Received 1986-05-14 CHG FTG 02/09/1985 & 12/30/84, RI 11/2/85
Construction Permit Expires 1986-10-29 CHG FTG 02/09/1985 & 12/30/84, RI 11/2/85
Change of Owner 2001-04-05 Operator changed from 457, ALSID OIL & GAS to 6970, VANGUARD OIL & GAS LLC
Record Last Modified 2017-02-15 CHG FTG 02/09/1985 & 12/30/84, RI 11/2/85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5723 5841 44
5723 5841 44
5723 5841 44

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 500 0 METHANOL
N2 0 2 Mscf 0 N2=1.6 SCF
H2O 0 36000 Gal 0
ACID 15 500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 ALSID OIL & GAS 6357.00 0.00 187
1987 ALSID OIL & GAS 10810.00 0.00 365
1988 ALSID OIL & GAS 10810.00 0.00 365
1989 ALSID OIL & GAS 7835.00 0.00 365
1990 ALSID OIL & GAS 5248.00 0.00 365
1991 ALSID OIL & GAS 3507.00 0.00 365
1992 ALSID OIL & GAS 3304.00 0.00 365
1993 ALSID OIL & GAS 2410.00 0.00 365
1994 ALSID OIL & GAS 2369.00 0.00 365
1998 ALSID OIL & GAS 1230.00 0.00 365
1999 ALSID OIL & GAS 1230.00 0.00 365
2000 VANGUARD OIL & GAS LLC 934.00 0.00 365
2001 VANGUARD OIL & GAS LLC 1024.00 0.00 365
2002 VANGUARD OIL & GAS LLC 1134.00 0.00 365
2003 VANGUARD OIL & GAS LLC 1242.00 0.00 365
2004 VANGUARD OIL & GAS LLC 1038.00 0.00 365
2005 VANGUARD OIL & GAS LLC 1198.00 0.00 365
2006 VANGUARD OIL & GAS LLC 1090.00 0.00 365
2007 VANGUARD OIL & GAS LLC 1326.00 0.00 365
2008 VANGUARD OIL & GAS LLC 1480.00 0.00 365
2009 VANGUARD OIL & GAS LLC 1760.00 0.00 365
2010 VANGUARD OIL & GAS LLC 2989.00 0.00 365
2011 VANGUARD OIL & GAS LLC 1194.00 0.00 0
2012 VANGUARD OIL & GAS LLC 1675.00 0.00 366
2013 VANGUARD OIL & GAS LLC 467.00 0.00 365
2014 VANGUARD OIL & GAS LLC 1987.00 0.00 365
2015 VANGUARD OIL & GAS LLC 1402.00 0.00 365
2016 VANGUARD OIL & GAS LLC 1749.00 0.00 365
2017 VANGUARD OIL & GAS LLC 1126.00 0.00 365
2018 VANGUARD OIL & GAS LLC 1337.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 ALSID OIL & GAS Brine 0 187
1987 ALSID OIL & GAS Brine 280 365
1988 ALSID OIL & GAS Brine 280 365
1989 ALSID OIL & GAS Brine 80 365
1990 ALSID OIL & GAS Brine 0 365
1991 ALSID OIL & GAS Brine 0 365
1992 ALSID OIL & GAS Brine 0 365
1993 ALSID OIL & GAS Brine 65 365
1994 ALSID OIL & GAS Brine 0 365
1998 ALSID OIL & GAS Brine 0 365
1999 ALSID OIL & GAS Brine 0 365
2000 VANGUARD OIL & GAS LLC Brine 0 365
2001 VANGUARD OIL & GAS LLC Brine 0 365
2002 VANGUARD OIL & GAS LLC Brine 0 365
2003 VANGUARD OIL & GAS LLC Brine 0 365
2004 VANGUARD OIL & GAS LLC Brine 0 365
2005 VANGUARD OIL & GAS LLC Brine 0 365
2006 VANGUARD OIL & GAS LLC Brine 23 365
2007 VANGUARD OIL & GAS LLC Brine 0 365
2008 VANGUARD OIL & GAS LLC Brine 0 365
2009 VANGUARD OIL & GAS LLC Brine 0 365
2010 VANGUARD OIL & GAS LLC Brine 0 365
2011 VANGUARD OIL & GAS LLC Brine 0
2012 VANGUARD OIL & GAS LLC Brine 0 366
2013 VANGUARD OIL & GAS LLC Brine 0 365
2014 VANGUARD OIL & GAS LLC Brine 365
2015 VANGUARD OIL & GAS LLC Brine 0 365
2016 VANGUARD OIL & GAS LLC Brine 0 365
2017 VANGUARD OIL & GAS LLC Brine 0 365
2018 VANGUARD OIL & GAS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0033665845 2016-11-07 Production Wells No Violations The purpose for my inspection was to conduct a status check on well # 2-1075. A review of RBDMS indicates the Operator is current with reporting production. Lease access to the well head and tank battery are stable. The well location is within an idle pasture field that is dominated by mature vegetation. The 8.625 surface casing is below grade. The 4.5 production casing is equipped with a ball valve and swage that reduces into the flow line. A motor valve is present to control flow. All production valves are in the open position. No audible or visual leaks were detected. Production equipment is contained within an earthen dike that is stable but weathered on the South side. Equipment within the dike consists of one (1) horizontal heater, one (1) horizontal separator and one (1) 100 bbl production tank. The heater is in good repair. No audible or visual leaks were detected. The horizontal separator is in good repair. No audible or visual were detected. A current production chart is in the meter house. Correct and legible identification is conspicuously displayed on the production tank stairs. The tank remains in good repair. No leaks were detected. The flow line into the tank is completely corroded through. The load line valve is closed and plugged. The drain line valve is closed and plugged. The hatch lid is closed. A review of RBDMS indicates the well does not produce production fluid. No violations were observed during this inspection.
33665845 2016-11-7 0:00: PW No Violations

For data sources see[9]

References