If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-20403 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.82,"lon":-80.73,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Fairfield Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: JONES WILBER | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1954-06-14 | |
Spud Drilling Contractor: | |
Final Drill Date: 1954-07-27 | |
Well Total Depth: 910.00 ft | |
Configuration: Vertical | |
Latitude: 40.820000 | |
Longitude: -80.730000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1954-06-14 | |
Completed | 1954-07-27 | |
Reached Total Depth | 1954-07-27 | |
Change of Owner | 2011-08-05 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2011-08-17 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | R.P. 24 HRS, 2ND R.P. 261#/72 HRS. |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1860718801 | 2016-5-13 0:00: | SO | No Violations | |
-28962417 | 2014-11-5 0:00: | SO | No Violations | 0.50 |
-474375254 | 2018-8-21 0:00: | SO | No Violations | 0.20 |
0028962417 | 2014-11-05 | Storage Well | No Violations | I inspected Columbia Gas storage well #4246. The well is equipped with a master gate valve and a side gate valve. There was no storage tank associated with the well. There was a domestic well. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable. No violations found. |
0474375254 | 2018-08-21 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check on storage well #2-0403. Access to the well was drivable and stable. Correct identification was present. The surface casing well head was above grade and closed to atmosphere. The 7 production casing was equipped with a master gate valve topped with a 7 riser tee. The top of the tee contained a closed and plugged valve. The side contained a wing valve and a 4.5 run leading to a buried drip ahead of the distribution line. A domestic supply connection was present. No leaks were observed. |
0551931020 | 2013-05-09 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well # 4246 today. The well is located in Section 31, Fairfield Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found. |
1514388911 | 2017-12-27 | Storage Well | No Violations | The purpose of my inspection was to document the status of well #2-0403. Access to the well was stable and drivable. Correct identification was posted at the well head. Annular side ports were plugged. The production casing was equipped with a master gate valve and side gate valve that lead to a 4.5 run and buried drip before leading to the main line. No leaks were observed. A domestic supply connection was present. No violations were observed during this inspection. |
1860718801 | 2016-05-13 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
2044917090 | 2015-06-22 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
551931020 | 2013-5-9 0:00:0 | SO | No Violations | |
574227583 | 2019-10-22 0:00 | SO | No Violations | 1.00 |
746934005 | 2020-1-23 0:00: | SO | No Violations | 1.00 |
For data sources see[4]