If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-019-22032 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.72,"lon":-81.19,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Carroll | |
Municipality: Brown Township | |
Operator Name: WILLIAM S MILLER INC | |
Well Pad ID: | |
Farm/Lease Name: GEIGER | |
License Status: Producing | |
License Date: 2007-12-31 | |
Spud Date: 2008-10-18 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 2008-10-25 | |
Well Total Depth: 5310.00 ft | |
Configuration: Vertical | |
Latitude: 40.720000 | |
Longitude: -81.190000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-12-31 | Proposed Formations:CLINTON, Issued Date:12/31/2007, Expired Date:12/30/2008 6:00:00 AM, Drilling unit acres:200.45, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-10-25 | |
Construction Permit Expires | 2008-12-30 | |
Completion Report Received | 2009-01-15 | |
Change of Owner | 2017-12-20 | Operator changed from 146, FOLTZ & FOLTZ LTD PARTNERSHIP to 2512, WILLIAM S MILLER INC |
Record Last Modified | 2017-12-20 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-03-06 | 5124 | 5216 | 34 |
5124 | 5216 | 34 | |
5124 | 5216 | 34 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 155000 Gal | 70000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | RANGE RESOURCES-APPALACHIA LLC | 7364.00 | 0.00 | 365 |
2009 | FOLTZ & FOLTZ LTD PARTNERSHIP | 4833.00 | 1311.00 | 365 |
2010 | FOLTZ & FOLTZ LTD PARTNERSHIP | 5760.00 | 874.00 | 365 |
2011 | FOLTZ & FOLTZ LTD PARTNERSHIP | 7511.00 | 761.00 | 365 |
2012 | FOLTZ & FOLTZ LTD PARTNERSHIP | 4988.00 | 499.00 | 366 |
2013 | FOLTZ & FOLTZ LTD PARTNERSHIP | 2837.00 | 263.00 | 365 |
2014 | FOLTZ & FOLTZ LTD PARTNERSHIP | 2060.00 | 733.00 | 365 |
2015 | FOLTZ & FOLTZ LTD PARTNERSHIP | 2341.00 | 235.00 | 365 |
2016 | FOLTZ & FOLTZ LTD PARTNERSHIP | 2160.00 | 266.00 | 365 |
2017 | WILLIAM S MILLER INC | 1550.00 | 0.00 | 0 |
2018 | WILLIAM S MILLER INC | 2790.00 | 423.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 750 | 31 |
2009 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 590 | 365 |
2010 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 440 | 365 |
2011 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 336 | 365 |
2012 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 153 | 366 |
2013 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 32 | 365 |
2014 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 39 | 365 |
2015 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 102 | 365 |
2016 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 164 | 365 |
2017 | FOLTZ & FOLTZ LTD PARTNERSHIP | Brine | 118 | 365 |
2018 | WILLIAM S MILLER INC | Brine | 246 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1225390966 | 2008-10-21 0:00 | DD | No Violations | 1.00 |
-1413930575 | 2008-7-29 0:00: | DD | No Violations | 1.00 |
-1471295268 | 2008-12-12 0:00 | DD | No Violations | 1.00 |
-1892692468 | 2009-10-26 0:00 | PL | No Violations | 1.00 |
-2111726198 | 2008-9-30 0:00: | DD | No Violations | 1.00 |
-22151685 | 2008-8-12 0:00: | DD | No Violations | 2.00 |
-743236457 | 2012-1-3 0:00:0 | PL | No Violations | 0.50 |
-758689028 | 2017-2-13 0:00: | PW | No Violations | 1.00 |
-888533861 | 2008-1-25 0:00: | DD | No Violations | 1.00 |
0022151685 | 2008-08-12 | Drill / Deepen / Reopen | No Violations | Last week Robert Foltz contacted me and advised that they would start building location today. Inspection revealed that a dozer has started building the location in the soybean field and started grubbing the trees on the north side of the wellsite. No violations at this time. |
0104635018 | 2008-09-10 | Drill / Deepen / Reopen | No Violations | Inspection revealed that they havent finished the location yet. They have the south side of the location partially built. They are still working on the north side removing trees and stumps. Nobody on site at this time. |
0427943428 | 2018-05-17 | Production Wells | No Violations | The well was equipped with a pumping unit. Oil staining was visible around the well head, but no mobile product was visible. The tank battery consisted of two 210 bbl production tanks, one 50 bbl brine tank, one vertical separator, and one meter run. Identifications for permit numbers (22048, 22054, 20232, 21983, and 22016) were posted on the production tanks. The load line to the tanks production valves were secured with plugs. Well ownership was recently transferred to William S Miller Inc. and updated identification was posted at the well and tank battery. No violations were observed at the time of inspection. The access road was stable. |
0743236457 | 2012-01-03 | Preliminary Restoration | No Violations | The PreliminaryRestoration was passed by Inspector Brett Farnsworth on 10-26-2009. This well is in production. There were no violations found at the time of my inspection. |
0758689028 | 2017-02-13 | Production Wells | No Violations | I conducted a status check of this well. The well is equipped with an electrically-driven pumpjack and the production valves were in the open position at the time of inspection. The tank battery shares production equipment with PN# 22054 &22048 and consists of two 210 bbl production tanks, one 50 bbl brine tank, one vertical separator, two drip bottles, and one meter run with a current chart. The tank battery is surrounded by a dike and the load line to the tanks production valves were equipped with locks and plugs. Identification was posted at the well and tank battery. |
0888533861 | 2008-01-25 | Drill / Deepen / Reopen | No Violations | Inspection revealed that the operator has not started building the location yet. No violations at this time. HB278 area. |
104635018 | 2008-9-10 0:00: | DD | No Violations | 0.50 |
1225390966 | 2008-10-21 | Drill / Deepen / Reopen | No Violations | Inspection revealed that Advent Drilling has moved off location. No violations at this time. |
1413930575 | 2008-07-29 | Drill / Deepen / Reopen | No Violations | Inspection revealed that there is a dozer on site at this time. No violations at this time. |
1471295268 | 2008-12-12 | Drill / Deepen / Reopen | No Violations | Inspection of the drilling pits revealed that the pits have been closed and location rough graded. No violations at this time. |
1672835121 | 2008-10-14 | Drill / Deepen / Reopen | No Violations | Inspection revealed that Advent Drilling is at 618 . No violations at this time. Daylight Driller Kenny Swoger advised that they should be ready to set surface later tonight. |
1892692468 | 2009-10-26 | Preliminary Restoration | No Violations | Inspection revealed that the prelominary restoration can be approved at this time. No violations. |
1954500847 | 2008-11-03 | Drill / Deepen / Reopen | No Violations | Inspection of the drilling pits revealed that the fluid levels are acceptable and the pit liners are intact. No violations at this time. |
2111726198 | 2008-09-30 | Drill / Deepen / Reopen | No Violations | Inspection revealed that there are no changes to the location since the last inspection. No violations at this time. |
427943428 | 2018-5-17 0:00: | PW | No Violations | 0.50 |
For data sources see[9]