Well Details

Well ID: 34-019-20436
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Rose Township
Operator Name: WILLIAM S MILLER INC
Well Pad ID:
Farm/Lease Name: GROSENBAUGH
License Status: Plugged and Abandoned
License Date: 2018-05-30
Spud Date: 1969-10-21
Spud Drilling Contractor:
Final Drill Date: 1970-05-12
Well Total Depth: 5510.00 ft
Configuration: Vertical
Latitude: 40.610000
Longitude: -81.240000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1969-05-20 311 STOCKER & SITLER INC GeoDate 5/20/69
Original Spud 1969-10-21 UPDATE COORDAINTES PER DOGRNM SURVEYOR
Completed 1970-05-12 UPDATE COORDAINTES PER DOGRNM SURVEYOR
Reached Total Depth 1970-05-12 UPDATE COORDAINTES PER DOGRNM SURVEYOR
Change of Owner 1999-07-20 Operator changed from 311, STOCKER & SITLER INC to 5785, M-J OIL COMPANY INC.
Change of Owner 2001-03-13 Operator changed from 5785, M-J OIL COMPANY INC. to 5894, G & O RESOURCES LTD
Change of Owner 2012-04-10 Operator changed from 5894, G & O RESOURCES LTD to 2512, MILLER WILLIAM S INC
APP 2018-05-30 Proposed Formations:CLINTON, Issued Date:5/30/2018, Expired Date:5/29/2020 12:00:00 PM, Drilling unit acres:160.98, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-07-07 UPDATE COORDAINTES PER DOGRNM SURVEYOR
Record Last Modified 2019-05-10 UPDATE COORDAINTES PER DOGRNM SURVEYOR
Construction Permit Expires 2020-05-29 UPDATE COORDAINTES PER DOGRNM SURVEYOR

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5312 0
2006-09-11 5348 5357 0
5312 0
5312 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 10000 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 STOCKER & SITLER INC 321.00 373.00 365
1985 STOCKER & SITLER INC 1221.00 481.00 0
1986 STOCKER & SITLER INC 840.00 278.00 365
1987 STOCKER & SITLER INC 646.00 305.00 365
1988 STOCKER & SITLER INC 559.00 323.00 0
1989 STOCKER & SITLER INC 592.00 434.00 365
1990 STOCKER & SITLER INC 1136.00 734.00 365
1991 STOCKER & SITLER INC 596.00 367.00 365
1992 STOCKER & SITLER INC 528.00 263.00 365
1993 STOCKER & SITLER INC 576.00 252.00 365
1994 STOCKER & SITLER INC 839.00 279.00 0
1995 STOCKER & SITLER INC 13.00 229.00 0
1996 STOCKER & SITLER INC 0.00 0.00 0
1997 STOCKER & SITLER INC 0.00 0.00 365
1998 STOCKER & SITLER INC 179.00 159.00 365
1999 M-J OIL COMPANY INC. 62.00 13.00 100
2000 M-J OIL COMPANY INC. 0.00 67.00 365
2001 M-J OIL COMPANY INC. 0.00 43.00 49
2002 G & O RESOURCES LTD 0.00 47.00 365
2003 G & O RESOURCES LTD 0.00 53.00 365
2004 G & O RESOURCES LTD 0.00 34.00 365
2005 G & O RESOURCES LTD 0.00 0.00 0
2006 G & O RESOURCES LTD 0.00 0.00 0
2007 G & O RESOURCES LTD 0.00 0.00 0
2008 G & O RESOURCES LTD 0.00 18.00 366
2009 G & O RESOURCES LTD 0.00 0.00 0
2010 G & O RESOURCES LTD 0.00 11.00 365
2012 WILLIAM S MILLER INC 0.00 0.00 0
2013 WILLIAM S MILLER INC 0.00 0.00 0
2014 WILLIAM S MILLER INC 0.00 0.00 0
2015 G & O RESOURCES LTD 0.00 0.00 0
2016 WILLIAM S MILLER INC 0.00 0.00 0
2017 WILLIAM S MILLER INC 0.00 0.00 0
2018 WILLIAM S MILLER INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 STOCKER & SITLER INC Brine 0 365
1985 STOCKER & SITLER INC Brine 0 0
1986 STOCKER & SITLER INC Brine 0 365
1987 STOCKER & SITLER INC Brine 0 365
1988 STOCKER & SITLER INC Brine 0 0
1989 STOCKER & SITLER INC Brine 0 365
1990 STOCKER & SITLER INC Brine 0 365
1991 STOCKER & SITLER INC Brine 0 365
1992 STOCKER & SITLER INC Brine 0 365
1993 STOCKER & SITLER INC Brine 0 365
1994 STOCKER & SITLER INC Brine 0 0
1995 STOCKER & SITLER INC Brine 0 0
1996 STOCKER & SITLER INC Brine 0 0
1997 STOCKER & SITLER INC Brine 164 365
1998 STOCKER & SITLER INC Brine 58 365
1999 STOCKER & SITLER INC Brine 0 365
2000 M-J OIL COMPANY INC. Brine 283 365
2001 M-J OIL COMPANY INC. Brine 18 49
2002 G & O RESOURCES LTD Brine 124 365
2003 G & O RESOURCES LTD Brine 15 365
2004 G & O RESOURCES LTD Brine 9 365
2005 G & O RESOURCES LTD Brine 0 0
2006 G & O RESOURCES LTD Brine 7 0
2007 G & O RESOURCES LTD Brine 0 0
2008 G & O RESOURCES LTD Brine 11 366
2009 G & O RESOURCES LTD Brine 17 0
2010 G & O RESOURCES LTD Brine 0 365
2012 WILLIAM S MILLER INC Brine 0 0
2013 WILLIAM S MILLER INC Brine 0 0
2014 WILLIAM S MILLER INC Brine 0 0
2015 WILLIAM S MILLER INC Brine 0 0
2016 WILLIAM S MILLER INC Brine 0 0
2017 WILLIAM S MILLER INC Brine 0 0
2018 WILLIAM S MILLER INC Brine 190 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1135914317 2018-7-8 0:00:0 PB No Violations 0.40
-1275162986 2013-8-22 0:00: AM No Violations
-1353779248 2018-5-21 0:00: PW No Violations 0.70
-1458764444 2015-10-15 0:00 PW No Violations
-184620718 2018-5-29 0:00: PW No Violations 3.00
-1938592777 2018-10-30 0:00 FR No Violations 0.50
-325544109 2019-10-28 0:00 FR No Violations 1.00
-803697649 2015-5-20 0:00: PW No Violations
0184620718 2018-05-29 Production Wells No Violations I was on site to conduct a compliance notice follow-up from a release which was discovered on 05/08/2018. The diked area around the well head contained water with oil product, and the water appeared to have breached the contained area. Sheen was present in the excavated area around the well. I met with the George Miller of William S Miller Inc. on site who agreed to plug the well during June of 2018. I stated that any product needs to be removed and recommended in the interim of plugging the well that a lined pit be installed near the well to contain any further contamination leaching from around the well, and the pit be regularly monitored for water levels. The compliance notice will be closed once all visible contamination has been removed.
0268041942 2017-03-08 Production Wells No Violations I spoke to David Miller of William S. Miller Inc. on 03/08/2017 regarding the plugging status of the well. He informed me that this well is on the list to be plugged and is hoping to start plugging operations in 2017.
0317877821 2018-07-06 Plug / Plug Back No Violations

-down operations for the night.

0348137348 2018-05-15 Production Wells No Violations I conducted a compliance notice follow-up on the well for pollution and contamination. The area around the well head, which was excavated and diked, contained water and visible oil product. Oil soak pads were in place. The well is located a low section of a farm field and intersects a natural drainage path. A shallow ditch west of the well was put in place to catch any drainage, and a boom was deployed. The boom appeared clean at the time of inspection. Cleanup was on going at the time of inspection. A stockpile of excavated and contaminated soil was located north of the well and on a liner proper disposal.
0803697649 2015-05-20 Production Wells Violations Noted Inspection showed the well is equipped with an electrically powered pump jack. The tubing valve is open. There is a line with a closed valve that is partially buried that may be the flow line or an old domestic line. The well head is overgrown with vegetation. One, 100 bbl. White rusty steel tank and 1, 50 bbl. Green steel tank are near the well. There is not a meter or separator at the tanks. The identification at the well shows G & O as the owner. The Division of Oil and Gas records show William Miller is the owner. The tank battery is overgrown with vegetation. There has been 0 production reported from 2012 through 2014. 0 barrels of oil were produced between 2005 and 2007. 18 barrels of oil were produced in 2008.0 barrels in 2009 and 11 barrels of oil in 2010. This well used to produce into the same tank battery as P. 435, 437 and 438. All four wells reported the same production. G & O and William Miller have been contacted to determine ownership and plans for this well.
0860511096 2018-12-11 Final Restoration No Violations I was on site for a final restoration inspection. The equipment and tank has been removed, but a pile of scrap was still present on site. It also appeared that the area still needed more grading and seeding. I will contact the operator. I witnessed plugging operations for this well which were finished on 07/07/2018. Plugging of the well has been fulfilled and the compliance notice issued to plug the well can be closed at this time.
1105735354 2018-07-07 Plug / Plug Back No Violations

<-

1135914317 2018-07-08 Plug / Plug Back No Violations I was on site to verify the cement top after plugging operations commenced on 07/07/2018. The service rig was off location and the temporary pit which was used during plugging operations had been emptied. I located the cement top to be at surface.
1275162986 2013-08-22 Administrative Inspection No Violations I was on inspection with Helen Halter. My inspection found the well to be shut in. Last reported production was in 2010, the operator reported 11 barrels of oil produced. There was no identification posted at the well or the tank battery. The well needs put back into production or plugged. Identification needs posted at the well site. Please contact Brett Farnsworth and advise him of your schedule for putting the well back into production or plugging. Bretts cell phone number is (330) 284-1409.
1353779248 2018-05-21 Production Wells No Violations I conducted a compliance notice follow-up inspection of the well for a release which was discovered on 05/08/2018. The water around the well head was near the brim of the dike and contaminated oil pads as well as free product was visible on the water. I contacted David Miller of William S Miller Inc. and requested the contaminated water be emptied to prevent overflowing. He stated a pumper was in route to change the contaminated oil soak pads. We also discussed the plugging schedule of the well which he stated should take place in June of 2018.
1357819755 2018-05-31 Production Wells No Violations I was on site for a compliance notice follow-up for the well causing pollution and contamination. A lined pit had been installed south of the well head to contain any further contamination leaching from the soil, and will remain in place until plugging operations commence. The pit was dry at the time of inspection. The contamination in the area west of the well head, which was visible on 05/29/2018, was no longer present, as well as most of any product located in the diked area around the well. The compliance notice will remain open at this time until further monitoring to ensure that all pollution and contamination has been removed. The precautionary containment pit is planned to stay in place until plugging operations are finished.
1446047373 2015-10-26 Production Wells No Violations Inspection showed the well is not in production and there is not a domestic connection. Weeds have been cut down around the tank battery and pump jack. A new Identification sign with William Miller, Inc. as owner has been posted. Bill Miller Jr. has been in discussion with Supervisor Hill and would like to put together a timeframe for plugging or producing the wells they own in this area that are not in production. The current compliance date for plugging this well is 12/01/2015.
1458764444 2015-10-15 Production Wells No Violations I conducted a status check of this well with DOGRM Regional Supervisor Tom Hill. The well is equipped with an electrically-driven pumpjack. The production valves were in the open position, but the polish rod did not appear to be lubricated, and the joints of the pumpjack showed signs of corrosion. The tank battery consists of one 100 bbl production tank and one 50 bbl brine tank. Proper identification had been posted at the well. A review of records in the State database shows that the last reported production was 11 bbls in 2006. The well is not equipped to produce at this time. The operator shall submit a plugging schedule to inspector Ashley Raff for approval within 30 days of 11/06/2015 at: Ohio Department of Natural Resources, Division of Oil and Gas, 3575 Forest Lake Drive Suite 150, Uniontown, Ohio 44685, per OAC 1501:9-11-05(B). The well owner/operator will be notified if the plugging schedule is approved or denied. As per the Compliance Notice on 06/01/2015, the well is to be plugged by 12/01/2015.
1480582169 2018-12-19 Production Wells No Violations I spoke to David Miller of William S. Miller on 12/13/2018 and informed him that I could not pass final restoration during my last inspection on 12/11/2018 due to debris from the well present on site and because the area did not appear graded and seeded. He stated that he was unaware that any debris was on site. As of my inspection on 12/19/2018, the stockpiled debris was still on site and further grading needed to be done. In response to the compliance notice issued on 05/18/2018 for the well causing pollution and contamination, all contamination appeared to have been remediated so the compliance notice can be closed.
1527775855 2018-05-08 Production Wells Violations Noted I conducted a compliance notice follow-up which was issued to plug the well on 01/06/2015. At the time of inspection, a leak appearing to come from around the well head was active, and contamination and mobile oil was present measuring approximately 50 x 10. The contamination travelled west in the field for approximately 150 west where visible contamination and scald diminished. I contact Dave Miller of William S Miller Inc, who met me on site. Visible product was excavated and area of well head exposed where it was discovered that the leak appeared be from a failed section of flowline near the well. An area around the well head was dug out and diked to holed water and further contamination leached from the soil. Clean up is ongoing. The operator agreed to apply for a plugging permit and plug the well as soon as possible.
1545332908 2018-07-05 Plug / Plug Back No Violations

-1000 lbs. The plug was set from 5492-4980 with 50 sacks of Class A cement with cottonseed hulls. I weighed the cement at 15.4 ppg. The pH of the mix water was 7.0 and chlorides were <-in overnight.

1938592777 2018-10-30 Final Restoration No Violations I was on site for final restoration. The production tank had been removed from site, but debris from the well was still present on location and vegetation had not yet been established. Final restoration cannot be passed at this time.
2095219012 2015-10-15 Production Wells Violations Noted I conducted a status check of this well with DOGRM Regional Supervisor Tom Hill. The well is equipped with an electrically-driven pumpjack. The production valves were in the open position. The polish rod did not appear to be lubricated, and the joints of the pumpjack showed signs of corrosion. Proper Identification was posted at the well. The tank battery consists of one 100 bbl production tank and one 50 bbl brine tank. A review of records in the State database shows that the last reported production was 11 bbls in 2006, and has not produced the regulatory-required minimum production since 2008, and has only once since 2004. No production has been reported for over two consecutive reporting periods. The well is not equipped for production at this time. The operator shall submit a plugging plan to inspector Ashley Raff for approval within 30 days at: Ohio Department of Natural Resources, Division of Oil and Gas, 3575 Forest Lake Drive Suite 150, Uniontown, Ohio 44685.
268041942 2017-3-8 0:00:0 PW No Violations
317877821 2018-7-6 0:00:0 PB No Violations 2.00
348137348 2018-5-15 0:00: PW No Violations 1.00
860511096 2018-12-11 0:00 FR No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0803697649 US-OH-129125 2015-08-03 Failure to legibly identify well
0803697649 US-OH-129126 2015-08-03 Well shall be plugged
1527775855 US-OH-114629 2019-01-15 9-1-07 Well operation causing pollution and contamination
2095219012 US-OH-121394 2019-01-15 NONE Well shall be plugged

For data sources see[9]