X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-013-21401

Well Details

Well ID: 34-013-21401
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Colerain Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001612
Farm/Lease Name: SMITH NE CLR BL
License Status: Producing
License Date: 2019-06-25
Spud Date: 2019-03-27
Spud Drilling Contractor:
Final Drill Date: 2019-08-09
Well Total Depth: 20496.00 ft
Configuration: Horizontal
Latitude: 40.110000
Longitude: -80.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2019-02-26 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:2/26/2019, Expired Date:2/25/2021 12:00:00 PM, Drilling unit acres:87.791, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2019-03-29
Construction Permit Expires 2021-02-25

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
10116 20374 0
10116 20374 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-412603975 2019-5-6 0:00:0 CS No Violations 4.00
-462145207 2019-9-10 0:00: PL No Violations 0.30
-473051901 2020-6-22 0:00: PL No Violations 0.50
-646603501 2019-8-7 0:00:0 DD No Violations 1.00
0412603975 2019-05-06 Casing String Witnessed No Violations On the day of my inspection I witnessed that Falcon Rig 39 had drilled the 22-inch diameter hole to a depth of 381 feet. Wyoming Casing crew ran 377 feet of 18.625-inch diameter J 55 casing at 87.5 pound per foot, with 3 feet of casing above Kelly Bushing, which is 14 feet above ground level. Cement basket was set at 288 feet. Schlumberger was on site and rigged up their cement head and loaded lines with 5 barrels of fresh water and pressure tested to 2000 pounds per square inch. Schlumberger established circulation with 70 barrels of fresh water and a 25-barrel gel spacer, washed up and then pumped 88 barrels 407 sacks of 15.6 pounds per gallon with a yield of 1.2 cubic feet per sack Class A cement mixed with 4.75 gallons of water per sack. Cement was displaced with 100 barrels of fresh water 20 barrels of good cement to surface. Plug was bumped at 200 pounds per square inch and pressured up to 750 pounds per square inch floats held with .5 barrels of flow back. I informed Ascent company man Steve Davenport that the casing must remain static until cement reaches a compressive strength of 500 pounds per square inch.
1588008717 2019-03-28 Casing String Witnessed No Violations On site inspection to witness the conductor casing cement job found the said well was spudded on 03/27/2019 by Precision Rat Hole drilling service. The rig has drilled 32 diameter well bore to a depth of 97 measured from ground level elevation. The rig inserted 98 of 24 diameter .375 wall weld connection casing. The casing was cemented by Petroset Cement Service using a 52 barrel class A cement mix consisting of 250 sacks of cement with a cement weight of 15.6 pound per gallon verified by weight of scale. The cement was displaced using 47 barrels of fresh water. Cement returns were witnessed to surface inside the tin horn cellar with 1 of cement being left in the cellar.
180288729 2019-8-9 0:00:0 DD No Violations 0.50
460842167 2020-4-7 0:00:0 PW No Violations 0.20
810108722 2019-10-28 0:00 CT No Violations 0.30

For data sources see[4]