X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-013-20659

Well Details

Well ID: 34-013-20659
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Warren Township
Operator Name: DIVERSIFIED PRODUCTION LLC
Well Pad ID:
Farm/Lease Name: BURGA THOMAS
License Status: Producing
License Date: 2012-03-21
Spud Date: 2012-05-23
Spud Drilling Contractor: G & L DRILLING
Final Drill Date: 2012-05-25
Well Total Depth: 2550.00 ft
Configuration: Vertical
Latitude: 39.960000
Longitude: -81.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-21 Proposed Formations:BEREA THRU KNOX, Issued Date:3/21/2012, Expired Date:3/21/2014 12:00:00 PM, Drilling unit acres:109.46, Proposed Well Type:OG, Proposed Well Class:EW
Reached Total Depth 2012-05-25 PRELIM WRC IN FILE
Completion Report Received 2013-01-15 PRELIM WRC IN FILE
Change of Owner 2014-02-06 Operator changed from 79, OXFORD OIL to 9216, ECLIPSE RESOURCES-OHIO LLC
Construction Permit Expires 2014-03-21 PRELIM WRC IN FILE
Change of Owner 2016-08-02 Operator changed from 9216, ECLIPSE RESOURCES-OHIO LLC to 8685, M & R INVESTMENTS OHIO LLC
Record Last Modified 2016-08-04 PRELIM WRC IN FILE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2013-10-17 1926 2502 123
1926 2502 123
1926 2502 123

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-06-13 H2O 28 3547 Bbl 30000 Producers Service Corporation STAGE 2
2013-06-11 H2O 15 6222 Bbl 50000 Producers Service Corporation STAGE 1

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2012 OXFORD OIL 0.00 0.00 0
2013 ECLIPSE RESOURCES-OHIO LLC 1291.00 0.00 127
2014 ECLIPSE RESOURCES-OHIO LLC 3013.00 176.00 365
2015 ECLIPSE RESOURCES-OHIO LLC 1373.00 127.00 365
2016 ECLIPSE RESOURCES-OHIO LLC 0.00 0.00 365
2017 M & R INVESTMENTS OHIO LLC 922.00 34.00 365
2018 M & R INVESTMENTS OHIO LLC 278.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2012 OXFORD OIL Brine 350
2013 ECLIPSE RESOURCES-OHIO LLC Brine 2060 127
2014 ECLIPSE RESOURCES-OHIO LLC Brine 2810 365
2015 ECLIPSE RESOURCES-OHIO LLC Brine 2699 365
2016 M & R INVESTMENTS OHIO LLC Brine 742 365
2017 M & R INVESTMENTS OHIO LLC Brine 1345 365
2018 M & R INVESTMENTS OHIO LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1206037997 2014-9-24 0:00: PW No Violations 1.00
-1743119025 2018-4-30 0:00: PW No Violations 0.50
-1806538254 2012-10-17 0:00 PL No Violations 0.50
-261092841 2014-9-24 0:00: PW No Violations 1.00
-851415078 2016-3-7 0:00:0 PW No Violations 1.00
-979825017 2017-5-30 0:00: PW No Violations 0.50
0207870281 2013-02-21 Production Wells No Violations On the day of my inspection the well was shut in and awaiting stimulation operations. No violations noted.
0249994734 2018-06-06 Production Wells No Violations On the day of my inspection I witnessed Production equipment included 2- 100 barrel tanks, a 37 barrel plastic brine tank, vertical separator, 1.5 inch diameter meter run with rotary style meter and drip all contained within an earthen dike. Meter reading was 2854 at the time of my inspection. The well was equipped with 4.5 inch diameter production casing, and 2.375 inch diameter tubing with rods and a Jenson Pumping unit with an natural gas motor. All valves were open and Identification tags were present and production was current. No violations were witnessed at the time of my inspection.
0261092841 2014-09-24 Production Wells No Violations On the day of my inspection the well had a pumping unit and all nessasary equipment to be capable of production. Tank battery contents included two 100 bbl oil storage tanks, mechanical separator, and one 50 bbl brine storage tank. No violations noted.
0743773032 2013-02-21 Production Wells No Violations On the day of my inspection the well was capable of production. No violations noted.
0851415078 2016-03-07 Production Wells No Violations On this day the well was equipped with a pumping unit, tubing, and rods. The well was actively pumping which indicates the capability of production. The tank battery consisted of two 100 barrel production fluid holding tanks, one 75 barrel fluid storage tank, and a mechanical separator. The site appeared to be in satisfactory condition.
0979825017 2017-05-30 Production Wells No Violations An inspection of this site revealed that the well is equipped with a pumping unit. The pumping unit was not operating during the inspection. The valve that leads to the production area was in the open position. The tank battery area consisted of two 100 barrel production fluid storage tanks, a mechanical separator, and a plastic production storage tank.
1021878342 2012-10-22 Production Wells No Violations On the day of my inspection the well was shut in and still waiting for fracturing operations. No violations noted.
1206037997 2014-09-24 Production Wells No Violations Onsite with Inspector Andrew Corder. Site contents include 2 100 bbl oil tanks, a 50 bbl brine tank, a mechanical seperator, and a pumping unit on the wellhead. Well has all the required equipment to produce.
1255764789 2013-01-16 Production Wells No Violations On the day of my inspection the well was capable of production and equipped with a pumping unit. No violations were noted.
1459621475 2020-2-13 0:00: PW No Violations 0.50
1743119025 2018-04-30 Production Wells No Violations This well is supplied with 4.5-inch diameter production casing, 2.375-inch diameter tubing, and rods. The well is produced by means of a pumping unit. The pumping unit was attached to the rods. There was a motor on the pumping unit that had belts connected to the unit. The unit appeared to be powered by natural gas that was piped from the well. The production facility contained two 100-barrel production fluid tanks, a 50-barrel brine storage tank, a charting system, and a vertical mechanical separator. Production records in the RBDMS system are current to 2016.
1788684035 2013-03-14 Completion Testing No Violations On the day of my inspection the well was still shut in and awaiting completion. No violations noted.
1806538254 2012-10-17 Preliminary Restoration No Violations This site is waiting for fracturing operations and restoration will be completed following fracturing. No violations noted.
207870281 2013-2-21 0:00: PW No Violations 0.50
249994734 2018-6-6 0:00:0 PW No Violations 0.80
743773032 2013-2-21 0:00: PW No Violations 0.50

For data sources see[9]

References