34-013-20312

Well Details

Well ID: 34-013-20312
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Pultney Township
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: COWEN ROBERT
License Status: Producing
License Date: 1979-12-13
Spud Date: 1980-03-22
Spud Drilling Contractor:
Final Drill Date: 1980-03-26
Well Total Depth: 2210.00 ft
Configuration: Vertical
Latitude: 40.050000
Longitude: -80.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-12-13 508 M C F OIL CO INC GeoDate 12/13/79
Original Spud 1980-03-22
Completed 1980-03-26
Reached Total Depth 1980-03-26
CO 1994-10-26 2512 MILLER WILLIAM S INC GeoDate 12/13/79
Change of Owner 1998-12-15 Operator changed from 2512, MILLER WILLIAM S INC to 5429, MILEY GAS COMPANY
Change of Owner 2005-09-19 Operator changed from 5429, MILEY GAS COMPANY to 1171, EQUITY OIL & GAS FUNDS IN
Correction to Well 2008-07-18 CORRECTION TO LOCATION INFORMATION: X= 2,480,365; Y= 751,536 AND ELEV= 1200'.
Record Last Modified 2019-06-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2020 2042 22
2020 2042 22
2020 2042 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 8250 Bbl 24500

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1994 WILLIAM S MILLER INC 43.00 0.00 92
1995 WILLIAM S MILLER INC 193.00 0.00 365
1996 WILLIAM S MILLER INC 14.00 0.00 365
1997 WILLIAM S MILLER INC 3.00 0.00 365
2007 EQUITY OIL & GAS FUNDS INC 65.00 0.00 365
2008 EQUITY OIL & GAS FUNDS INC 290.00 0.00 365
2009 EQUITY OIL & GAS FUNDS INC 1266.00 0.00 365
2010 EQUITY OIL & GAS FUNDS INC 602.00 0.00 365
2011 EQUITY OIL & GAS FUNDS INC 55.00 0.00 0
2012 EQUITY OIL & GAS FUNDS INC 328.00 0.00 365
2013 EQUITY OIL & GAS FUNDS INC 213.00 0.00 365
2014 EQUITY OIL & GAS FUNDS INC 201.00 0.00 150
2015 EQUITY OIL & GAS FUNDS INC 0.00 0.00 0
2016 EQUITY OIL & GAS FUNDS INC 0.00 0.00 0
2017 EQUITY OIL & GAS FUNDS INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1994 WILLIAM S MILLER INC Brine 0 92
1995 WILLIAM S MILLER INC Brine 0 365
1996 WILLIAM S MILLER INC Brine 0 365
1997 WILLIAM S MILLER INC Brine 0 365
2007 EQUITY OIL & GAS FUNDS INC Brine 0 365
2008 EQUITY OIL & GAS FUNDS INC Brine 0 365
2009 EQUITY OIL & GAS FUNDS INC Brine 0 365
2010 EQUITY OIL & GAS FUNDS INC Brine 0 365
2011 EQUITY OIL & GAS FUNDS INC Brine 45
2012 EQUITY OIL & GAS FUNDS INC Brine 0 365
2013 EQUITY OIL & GAS FUNDS INC Brine 0 365
2014 EQUITY OIL & GAS FUNDS INC Brine 77 150
2015 EQUITY OIL & GAS FUNDS INC Brine 0 0
2016 EQUITY OIL & GAS FUNDS INC Brine 0 0
2017 EQUITY OIL & GAS FUNDS INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1121191262 2006-1-27 0:00: PW No Violations
-1263937287 2019-2-7 0:00:0 PW No Violations 1.00
-1386980035 2018-3-19 0:00: PW No Violations 0.50
-1748163481 2017-8-25 0:00: PW No Violations 1.00
-2023462351 2020-2-28 0:00: PW No Violations 0.50
-443110147 2008-10-15 0:00 PW No Violations
-777859165 2018-11-1 0:00: PW No Violations 0.70
-943595837 2018-10-18 0:00 PW No Violations 1.00
0076853225 2007-01-31 Production Wells No Violations STATUS CHECK
0443110147 2008-10-15 Production Wells No Violations WELL IS NEXT IN LINE TO BE WORKED OVER.
0558965890 2013-04-18 Production Wells No Violations On the day of my inspection the well was equipped with a pumping unit and capable of production. GPS update. No violations noted.
0777859165 2018-11-01 Production Wells No Violations Status check inspection found the well equipped with 4.5 diameter production casing and 1.900 diameter production tubing with both casing and tubing well heads present. Attached to the casing well head is a 2 diameter production flow line with a valve present in line and in the open position. Attached to the 1.900 diameter tubing is a tubing well head with a 2 diameter flow line present with a valve present in the closed position. There is a polish rod liner inserted into the tubing head with pumping rods present in the production tubing. The well is being produced by the means of a pumping unit driven by an electrical motor. Also present on the way back to the well head is a production facility that is shared between 2 wells in the area. The facility is equipped with 2 mechanical separators and 2 gas sales meters with 7 day sales chart in the meters. A single 100 barrel steel tank is present along with (2) plastic 2,100 gallon tanks. There is also a gas compressor and cooling manifold present in the storage area. All equipment noted in the storage area is situated inside an earthen dike area with well identification noted.
0943595837 2018-10-18 Production Wells Violations Noted On the day of my inspection accompanied by ODNR Supervisor Mike Moreland, I witnessed production equipment was shared with 34013205990000 and included a 100-barrel tank, and two 37-barrel plastic tanks, vertical separator, and 2-inch meter run with a .250-inch orifice and drip, and a small compressing unit and cooling manifold enclosed in an earthen dike. At the time of my inspection one of the 37-barrel plastic brine tanks had a 1-inch diameter plastic drain line through the earthen dike. I will contact Equity resources that the drain line needed to be removed. The tank valve was open, and the tank was empty at the time of my inspection. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, 1.5-inch diameter tubing and rods with a Churchill pumping unit, and an electric motor. When we arrived on location Andrew Ulrich of Amtek Oil was currently on location and cleaning up around the production equipment, after speaking with Andrew he informed us that he had been pumping the well for the past two days and they intended on purchasing the wells from Equity Oil and Gas Fund. After further investigation we discovered that he was currently pumping the production water through the 1-inch diameter valve on the pumping Tee directly onto the ground, there was a puddle approximately 10 feet in diameter near the well head. A field test was performed using Quantab titration test strips and revealed chlorides to be approximately 542 parts per million. We informed Andrew that he was not permitted to pump the water onto the ground, and he closed the valve and ran it to the production facility. Identification tags were not present, and production was reported as 0 since 2014. Equity resources will be contacted an informed of the issues that were encountered.
1057018835 2008-07-24 Production Wells No Violations WELL IN PRODUCTION
1121191262 2006-01-27 Production Wells No Violations NON PRODUCING
1263937287 2019-02-07 Production Wells No Violations The purpose of my inspection was to follow up on a previously issued compliance notice. On the day of my inspection I witnessed production area was shared with 34013205990000 and included a 100-barrel tank, and two 37-barrel plastic tanks, vertical separator, and 2 2-inch diameter meter runs with a .250-inch orifice and drip, and a small compressing unit and cooling manifold enclosed in an earthen dike, it appeared that the well was using one vertical separator and one 37 barrel plastic tank as storage for production fluid. At the time of my inspection one of the 37-barrel plastic brine tanks had a 1-inch diameter plastic drain line through the earthen dike. The tank valve was closed, and the tank was empty at the time of my inspection. The well was equipped with 8.625-inch diameter surface casing, 4.5-inch diameter production casing, 1.5-inch diameter tubing and rods with a Churchill pumping unit, and an electric motor. All valves were closed at the time of my inspection, and new identification had been posted in the production area. At the time of my inspection the well was no longer causing pollution and contamination and the compliance issue had been resolved.
1386980035 2018-03-19 Production Wells No Violations On the day of my inspection the well was equipped with a pumping unit, 1.5-inch diameter tubing, and rods. The production casing is 4.5-inches in diameter. There was a natural gas motor present on the pumping unit. There was an electric motor present on the pumping unit. The motor had belts that were attached from the motor to the pumping unit. The production area included one 100-barrel production fluid holding tank, two 37-barrel plastic tanks, a vertical mechanical separator, and a charting system. Zero production reported for 2016.
1580143722 2020-1-27 0:00: PW No Violations 0.50
1748163481 2017-08-25 Production Wells No Violations This well is equipped with a pumping unit, tubing, and rods and 4.5-inch diameter casing. The pumping unit is connected to the rods. The pumping unit did contain a motor and belts. The production area contained one 100-barrel production fluid holding tank and a vertical mechanical separator. This well has no shown production since 2014.
558965890 2013-4-18 0:00: PW No Violations 1.00
76853225 2007-1-31 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0943595837 US-OH-130792 2019-02-27 Well operation causing pollution and contamination

For data sources see[9]