X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-24153

Well Details

Well ID: 34-007-24153
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Kingsville Township
Operator Name: PLATEAU ENERGY CORP
Well Pad ID:
Farm/Lease Name: ANDERSON
License Status: Producing
License Date: 1999-08-16
Spud Date: 1999-10-26
Spud Drilling Contractor: FERGUSON DRILLING
Final Drill Date: 1999-11-20
Well Total Depth: 1525.00 ft
Configuration: Vertical
Latitude: 41.880000
Longitude: -80.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-08-16 Proposed Formations:OHIO SHALE, Issued Date:8/16/99, Expired Date:8/15/00 6:00:00 AM, Drilling unit acres:64, Proposed Well Type:OG, Proposed Well Class:ESPW
Original Spud 1999-10-26 RBDMS Rec
Completed 1999-11-20 RBDMS Rec
Reached Total Depth 1999-11-20 RBDMS Rec
Construction Permit Expires 2000-08-15 RBDMS Rec
Completion Report Received 2004-03-01 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1341357479 2019-4-11 0:00: PW No Violations
-1471644800 2003-12-29 0:00 PL No Violations
0262437840 2018-10-24 Production Wells Violations Noted I conducted an inspection on this well. At the time of this inspeciton, the well was not in production, and consisted of an 8 5/8 casing with tubing exposed and a gate valve attached on the tubing. The gate valve was closed. There were no flow lines connected to the well. No production records have been submitted for this well. There was no production equipment associated with this well. Access to the well was through a path in the woods. The well owner shall submit a written plugging schedule to Inspector Shannon Mullins at ODNR Division of Oil and Gas Resources Management, 3575 Forest Lake Drive, Suite 150, Uniontown, OH 44685 within 30 days. The well owner/operator will be notified if the plugging schedule is approved or denied. In the interim, the owner must correct the identification sign.
0814496788 2018-09-14 Production Wells No Violations I conducted an order follow-up inspection for Chiefs order #2014-202 for failure to maintain liability insurance. The well was shut--in and consisted of a 8 and 5/8 casing with tubing exposed and a gate valve attached on the tubing. At the time of the inspection, the pressure reading on the gauge showed zero. No other production equipment was associated with this well and the well is incapable of production. This well was drilled in 1999, and production has never been reported for this well. No insurance is on file from Plateau Energy Corp.
1145401376 2018-02-14 Production Wells No Violations I inspected this well as a follow-up to Chiefs Order #2014-202 for failure to maintain liability insurance. At the time of this inspection, the well was not capable of being produced. There was a surface casing with production casing with closed Demco valve. There were no active flow-line connections. The were was a tank battery and separator associated with the Anderson 1 (#2-4076), to which this well may have produced historically. There remained no active liability insurance on file for Plateau Energy Corp.
1235861309 2015-09-21 Production Wells No Violations I was on site to conduct a Chief s order follow-up inspection of this well. The wellhead was shut--in and consisted of a 8 and 5/8 casing with tubing exposed and a gate valve attached to the tubing. At the time of the inspection, the pressure reading on the gauge showed zero. No other production equipment was associated with this well and the well is incapable of production at this time. This well was drilled in 1999, and RBDMS shows no production records since the well has been drilled.
1341357479 2019-04-11 Production Wells No Violations I conducted a compliance notice follow-up on 04/11/2019. At the time of my inspection the well was not in production, and consisted of an 8 5/8 casing with 2 3/8-inch tubing inside the 8 5/8-inch well head. There was a gate valve on top of the tubing. The gate valve was shut. There were no flow lines connected to the well. There was no production equipment associated with this well. Access to the well was through a path in the woods. Compliance has not yet been taken care of or a plugging permit obtained.
1360270140 2020-3-26 0:00: PW No Violations
1471644800 2003-12-29 Preliminary Restoration No Violations Restoration approved .
1738494783 2017-08-14 Production Wells No Violations I conducted an order follow-up inspection for Chiefs order #2014-202 for failure to maintain liability insurance. The well was shut--in and consisted of a 8 and 5/8 casing with tubing exposed and a gate valve attached on the tubing. At the time of the inspection, the pressure reading on the gauge showed zero. No other production equipment was associated with this well and the well is incapable of production. This well was drilled in 1999, and production has never been reported for this well. No insurance is on file from Plateau Energy Corp.
262437840 2018-10-24 0:00 PW No Violations
676802927 2020-1-27 0:00: PW No Violations
814496788 2018-9-14 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0262437840 US-OH-122709 2018-11-16 9-9-05(A)10 Failure to legibly identify well
0262437840 US-OH-122710 2018-11-16 NONE Well shall be plugged

For data sources see[4]

References