34-007-23763

Well Details

Well ID: 34-007-23763
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Rome Township
Operator Name: PLATEAU ENERGY CORP
Well Pad ID:
Farm/Lease Name: CARTRIGHT N& M
License Status: Producing
License Date: 1987-09-17
Spud Date: 1987-09-26
Spud Drilling Contractor: EDCO DRLG
Final Drill Date: 1987-10-01
Well Total Depth: 3557.00 ft
Configuration: Vertical
Latitude: 41.630000
Longitude: -80.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1987-09-17 2614 SHEPHERD DAVE GeoDate 9/17/87
Oil and Gas 1987-09-17 Issued Date 9/17/87 Expired Date 9/16/88 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03557 Proposed Drill Depth 03557
Original Spud 1987-09-26 PERMIT EXPIRED,
Completed 1987-10-01 PERMIT EXPIRED,
Reached Total Depth 1987-10-01 PERMIT EXPIRED,
Completion Report Received 1987-10-27 PERMIT EXPIRED,
Construction Permit Expires 1988-09-16 PERMIT EXPIRED,
Change of Owner 2000-08-03 Operator changed from 2614, SHEPHERD DAVE to 4415, PLATEAU ENERGY CORP
Record Last Modified 2017-02-15 PERMIT EXPIRED,

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3408 3447 39
3408 3447 39
3408 3447 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 500 Gal 50000 FRAC:WATER&SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 PLATEAU ENERGY CORP 606.00 11.00 365
2009 PLATEAU ENERGY CORP 738.00 36.00 300
2011 PLATEAU ENERGY CORP 983.00 25.00 360

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 PLATEAU ENERGY CORP Brine 0 365
2009 PLATEAU ENERGY CORP Brine 45 300
2011 PLATEAU ENERGY CORP Brine 65 360

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1103139722 2020-3-27 0:00: PW No Violations
-1521137219 2018-2-14 0:00: PW No Violations 1.00
-218185432 2015-9-22 0:00: PW No Violations
-559337719 2020-5-7 0:00:0 PW No Violations
-580257913 2015-11-19 0:00 PW No Violations
-633643835 2018-8-22 0:00: PW No Violations
0218185432 2015-09-22 Production Wells Violations Noted I was on site to conduct a order follow-up inspection on this well. The last reported commercial production for this well was in 2011. The well is equipped with a pump jack and the valves were open. The well is also being used for domestic gas. The stuffing box around the wellhead was oil stained and covered in parrafin. There was oil staining around the wellhead that measured 5 feet by 8 feet. The tank battery consisted of one 100 BBL production tank and a mechanical separator. There was oil stained soil inside the tank battery dike and under the mechanical separator but was not visible outside of the dike. The tank battery, wellhead and lease road were very overgrown with vegetation. There was no signage associated with this well. The following needs completed by:

1) Clean-up and remove any contaminated oil stained soil inside of the tank battery and around the wellhead (11-06-15) 2) Remove overgrown vegetation around the wellhead, tank battery and lease access (11-06-15) 3) Identification sign posted (10-20-15)

0252038587 2006-01-20 Production Wells No Violations no violations .
0580257913 2015-11-19 Production Wells No Violations I was on site to conduct an inspection of this well. No changes since the last report on 11/06/2015.
0633643835 2018-08-22 Production Wells No Violations I conducted a compliance notice follow-up for compliance notice 218185432. At the time of this inspection, the well was equipped with a pumping unit and the valve on the tubing flow line was open. There was a domestic line plumbed off of the 4.5 inch casing with a closed valve. The stuffing box around the wellhead was still oil stained and covered in parrafin. There was oil staining around the wellhead still has not been cleaned up. The oil stained soil inside the tank battery dike and under the mechanical separator has not been cleaned up and remedied. The well location was very overgrown with weeds and phragmites. The tank battery consisted of one 100 BBL tank and a mechanical separator. Valves on the separator were open. The diked tank battery did not have legible signage and was very overgrown with phragmites and wetland vegetation. Lease access was stable.
0696528938 2016-01-15 Production Wells No Violations I was on site to conduct an inspection of this well. There have been no changes since the last report dated 11/19/2015.
1447960414 2015-11-06 Production Wells No Violations I was on site for a follow-up inspection to the compliance notice issued on 9/22/2015 for this well. No changes have occurred since the last inspection. I spoke with Charlie Moseo owner of Plateau Energy Corp about when the well and tank battery clean-up efforts would begin. He indicated that he would be on site the following week to begin addressing the compliance issues.
1521137219 2018-02-14 Production Wells No Violations I inspected this well as a follow-up to Chiefs Order #2014-202 for failure to maintain liability insurance. At the time of this inspection, but the well was not being produced commercially based on the closed flow-line connections. The was a pump jack unit and associated tank battery (comprised of one 100-barrel steel production tank with mechanical separator). The well and battery are located in an area of dense over-growth of tall grasses and wetlands vegetation. Elements of the system appeared to be in disrepair and the flow-line connections were closed. The had been previously-noted releases of oil from the wellhead and tank battery. The surface areas were obscured by snow cover and not available for visible assessment. There remained no active liability insurance on file for Plateau Energy Corp.
1553533538 2019-03-25 Production Wells No Violations I conducted a compliance notice follow--barrel production tank, and mechanical separator. Valves were shut at separator. No visible oil staining or contamination was observed inside of tank battery that was previously stated in other reports. Tank battery is overgrown with swap grass. No identification was posted. Lease road in fair condition.
252038587 2006-1-20 0:00: PW No Violations
696528938 2016-1-15 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0218185432 US-OH-122166 2015-11-02 Well operation causing pollution and contamination
0218185432 US-OH-122167 2015-11-02 Failure to legibly identify well
0218185432 US-OH-122168 2015-11-02 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]