Well ID: 34-007-23738
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Plymouth Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: HOGAN
License Status: Producing
License Date: 1987-01-14
Spud Date: 1987-02-01
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1987-02-06
Well Total Depth: 3166.00 ft
Configuration: Vertical
Latitude: 41.850000
Longitude: -80.720000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1987-01-14 Issued Date 1/14/87 Expired Date 1/14/88 Acres 0000000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03166 Proposed Drill Depth 03166
Original Spud 1987-02-01
Completed 1987-02-06
Reached Total Depth 1987-02-06
CO 1987-03-19 254 EDCO DRILLING & PRODUCING GeoDate 1/14/87
Completion Report Received 1987-03-30
Construction Permit Expires 1988-01-14
CO 1993-12-15 1111 MERIDIAN ENERGY COMPANY GeoDate 1/14/87
Change of Owner 2015-10-15 Operator changed from 1111, MERIDIAN ENERGY COMPANY to 1333, BIG SKY ENERGY INC TRANSFERRED WELL PER CHANGE OF OWNER DATED 2/8/1999 ON 10/15/2015 CM.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2976 2984 0
2959 3082 0
1997-06-29 2959 3082 0
2976 2984 0
2959 3082 0
2006-09-11 3016 3026 0
2006-09-11 2996 3004 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 50000 FRAC W/1500 BW & 500 SX SAND
ACID 15 250 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 EDCO DRILLING & PRODUCING 15417.00 0.00 365
1988 EDCO DRILLING & PRODUCING 8052.00 77.00 336
1989 EDCO DRILLING & PRODUCING 4949.00 89.00 365
1990 EDCO DRILLING & PRODUCING 4567.00 0.00 365
1991 EDCO DRILLING & PRODUCING 2977.00 60.00 365
1992 EDCO DRILLING & PRODUCING 2763.00 0.00 365
1993 EDCO DRILLING & PRODUCING 1463.00 0.00 200
1994 MERIDIAN ENERGY COMPANY 1754.00 0.00 365
1995 MERIDIAN ENERGY COMPANY 1323.00 0.00 365
1996 MERIDIAN ENERGY COMPANY 627.00 0.00 365
1997 MERIDIAN ENERGY COMPANY 649.00 0.00 365
1999 MERIDIAN ENERGY COMPANY 1410.00 0.00 365
2000 MERIDIAN ENERGY COMPANY 1752.00 35.00 365
2001 BIG SKY ENERGY INC 221.00 0.00 365
2002 MERIDIAN ENERGY COMPANY 0.00 109.00 365
2003 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2004 MERIDIAN ENERGY COMPANY 0.00 0.00 0
2005 MERIDIAN ENERGY COMPANY 128.00 0.00 365
2006 MERIDIAN ENERGY COMPANY 597.00 0.00 365
2007 MERIDIAN ENERGY COMPANY 930.00 0.00 365
2008 MERIDIAN ENERGY COMPANY 1864.00 0.00 365
2009 MERIDIAN ENERGY COMPANY 1835.00 0.00 365
2010 MERIDIAN ENERGY COMPANY 1645.00 0.00 365
2011 BIG SKY ENERGY INC 145.00 0.00 365
2012 BIG SKY ENERGY INC 496.00 0.00 366
2013 BIG SKY ENERGY INC 174.00 6.00 250
2014 BIG SKY ENERGY INC 1.00 0.00 250
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 EDCO DRILLING & PRODUCING Brine 1017 365
1988 EDCO DRILLING & PRODUCING Brine 491 336
1989 EDCO DRILLING & PRODUCING Brine 234 365
1990 EDCO DRILLING & PRODUCING Brine 425 365
1991 EDCO DRILLING & PRODUCING Brine 121 365
1992 EDCO DRILLING & PRODUCING Brine 235 365
1993 EDCO DRILLING & PRODUCING Brine 68 200
1994 MERIDIAN ENERGY COMPANY Brine 98 365
1995 MERIDIAN ENERGY COMPANY Brine 0 365
1996 MERIDIAN ENERGY COMPANY Brine 71 365
1997 MERIDIAN ENERGY COMPANY Brine 143 365
1999 MERIDIAN ENERGY COMPANY Brine 281 365
2000 MERIDIAN ENERGY COMPANY Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 MERIDIAN ENERGY COMPANY Brine 0 365
2003 MERIDIAN ENERGY COMPANY Brine 0 365
2004 MERIDIAN ENERGY COMPANY Brine 0 0
2005 MERIDIAN ENERGY COMPANY Brine 0 365
2006 MERIDIAN ENERGY COMPANY Brine 0 365
2007 MERIDIAN ENERGY COMPANY Brine 0 365
2008 MERIDIAN ENERGY COMPANY Brine 0 365
2009 MERIDIAN ENERGY COMPANY Brine 0 365
2010 MERIDIAN ENERGY COMPANY Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 250
2014 BIG SKY ENERGY INC Brine 0 250
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1511234629 2017-10-31 0:00 SC No Violations 0.50
-333815709 2006-10-20 0:00 PW No Violations
-710258836 2018-3-13 0:00: PW No Violations 1.00
0270017113 2016-05-04 Production Wells Violations Noted My inspection found the tank battery was equipped with one 100 barrel steel tank and one separator. There was no identification posted at the tank battery area. The well was equipped with a plunger lift unit. The valves from the well to the flow line were closed. There was a active domestic hook-up from the tubing head. This well was not in production at the time of my inspection. REQUIRED REMEDIAL WORK: Post identification at the tank battery area.
0333815709 2006-10-20 Production Wells No Violations no violations .
0710258836 2018-03-13 Production Wells No Violations I inspected this well pursuant to Chiefs Order #2016-300 issued for lack of insurance. The well and associated battery are located on a rural farm parcel. At the time of this inspection, I noted the following: a wellhead plunger-lift in a wooded clearing. The main flow-line valve was closed. The well was not in production. The fittings were secure with no signs of leakage. The associated tank battery was comprised of one 100-barrel production tank, and horizontal separator. The tank was empty. There was a chart record box that was not active. I walked the areas around the well and battery. The areas were covered with several inches of snow obscuring the ground surface. I did not observe any signs of problems. The elements were in disrepair. There was no identification signage.
0761456009 2018-07-03 Production Wells No Violations I inspected this well location as part of a compliance notice follow-up. As such, the following deficiencies had been noted: lack of complete identifying signage. At the time of this inspection, I noted the following: ID signage was still not present. The flow-line connections were closed and the chart recorder was not active. The areas surrounding the battery were overgrown significantly with phragmites.
1511234629 2017-10-31 Surface Facility Construction No Violations I inspected this well locaiton as part of a compliance notice follow-up. As such, the following defficieincies had been noted: lack of complete identifying signage. At the time of this inspection, I noted the following: a wellhead with plunger lift system and associated battery on a larger, rural parcel. The battery was comprised of one 100-barrel, steel production tank, and horizontal separator. Fittings and connections at the wellhead were secure with no signs of leakge. ID signage was not present. I noted the chart box was missing a chart. The areas surrounding the battery were overgrown signifiantly with phragmites. No changes had been made to the signage.
270017113 2016-5-4 0:00:0 PW No Violations
761456009 2018-7-3 0:00:0 PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0270017113 US-OH-122794 2016-07-26 9-9-05(A)10 Failure to legibly identify well