34-007-22742

Well Details

Well ID: 34-007-22742
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Sheffield Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: BALDIN
License Status: Producing
License Date: 1984-05-16
Spud Date: 1984-11-03
Spud Drilling Contractor: EDCO DRLG
Final Drill Date: 1984-11-08
Well Total Depth: 3250.00 ft
Configuration: Vertical
Latitude: 41.830000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-05-16 254 EDCO DRILLING & PRODUCING GeoDate 5/16/84
Oil and Gas 1984-05-16 Issued Date 5/16/84 Expired Date 11/12/84 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03250 Proposed Drill Depth 03250
Original Spud 1984-11-03
Completed 1984-11-08
Reached Total Depth 1984-11-08
Construction Permit Expires 1984-11-12
Completion Report Received 1984-12-10
CO 1993-10-22 1111 MERIDIAN ENERGY COMPANY GeoDate 5/16/84
Change of Owner 2015-10-15 Operator changed from 1111, MERIDIAN ENERGY COMPANY to 1333, BIG SKY ENERGY INC TRANSFERRED WELL PER CHANGE OF OWNER DATED 2/8/1999 ON 10/15/2015 CM.
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3045 3103 37
3045 3103 37
3045 3103 37

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 0
H2O 0 18000 Bbl 50000 FRAC: H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EDCO DRILLING & PRODUCING 6999.00 93.00 287
1986 EDCO DRILLING & PRODUCING 5507.00 92.00 365
1987 EDCO DRILLING & PRODUCING 2790.00 0.00 365
1988 EDCO DRILLING & PRODUCING 3318.00 95.00 334
1989 EDCO DRILLING & PRODUCING 4793.00 0.00 365
1990 EDCO DRILLING & PRODUCING 2676.00 92.00 365
1991 EDCO DRILLING & PRODUCING 1089.00 0.00 365
1992 EDCO DRILLING & PRODUCING 1296.00 80.00 365
1993 EDCO DRILLING & PRODUCING 570.00 0.00 200
1994 MERIDIAN ENERGY COMPANY 931.00 63.00 365
1995 MERIDIAN ENERGY COMPANY 565.00 0.00 365
1996 MERIDIAN ENERGY COMPANY 1977.00 44.00 365
1997 MERIDIAN ENERGY COMPANY 1171.00 0.00 365
1999 MERIDIAN ENERGY COMPANY 403.00 0.00 365
2001 BIG SKY ENERGY INC 101.00 0.00 365
2002 MERIDIAN ENERGY COMPANY 415.00 0.00 365
2003 MERIDIAN ENERGY COMPANY 969.00 76.00 365
2004 MERIDIAN ENERGY COMPANY 846.00 0.00 365
2005 MERIDIAN ENERGY COMPANY 313.00 0.00 365
2006 MERIDIAN ENERGY COMPANY 569.00 0.00 365
2007 MERIDIAN ENERGY COMPANY 475.00 0.00 365
2008 MERIDIAN ENERGY COMPANY 294.00 0.00 365
2009 MERIDIAN ENERGY COMPANY 1029.00 0.00 365
2010 MERIDIAN ENERGY COMPANY 624.00 70.00 365
2011 BIG SKY ENERGY INC 373.00 0.00 365
2012 BIG SKY ENERGY INC 527.00 0.00 366
2013 BIG SKY ENERGY INC 1545.00 0.00 365
2014 BIG SKY ENERGY INC 724.00 0.00 250
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EDCO DRILLING & PRODUCING Brine 775 287
1986 EDCO DRILLING & PRODUCING Brine 482 365
1987 EDCO DRILLING & PRODUCING Brine 337 365
1988 EDCO DRILLING & PRODUCING Brine 355 334
1989 EDCO DRILLING & PRODUCING Brine 341 365
1990 EDCO DRILLING & PRODUCING Brine 174 365
1991 EDCO DRILLING & PRODUCING Brine 0 365
1992 EDCO DRILLING & PRODUCING Brine 70 365
1993 EDCO DRILLING & PRODUCING Brine 68 200
1994 MERIDIAN ENERGY COMPANY Brine 136 365
1995 MERIDIAN ENERGY COMPANY Brine 0 365
1996 MERIDIAN ENERGY COMPANY Brine 215 365
1997 MERIDIAN ENERGY COMPANY Brine 76 365
1999 MERIDIAN ENERGY COMPANY Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 MERIDIAN ENERGY COMPANY Brine 0 365
2003 MERIDIAN ENERGY COMPANY Brine 0 365
2004 MERIDIAN ENERGY COMPANY Brine 0 365
2005 MERIDIAN ENERGY COMPANY Brine 0 365
2006 MERIDIAN ENERGY COMPANY Brine 0 365
2007 MERIDIAN ENERGY COMPANY Brine 0 365
2008 MERIDIAN ENERGY COMPANY Brine 0 365
2009 MERIDIAN ENERGY COMPANY Brine 0 365
2010 MERIDIAN ENERGY COMPANY Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 250
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1712581528 2005-4-13 0:00: PW No Violations
-917937709 2016-4-20 0:00: PW No Violations
0087072387 2016-12-19 Production Wells No Violations My inspection of this well found there has been no remedial work done to resolve the compliance issues with this well. There was no way to determine if the tank had been emptied. There area the tank had been dripping fluid onto the ground was frozen at the time of my inspection.
0412036641 2018-03-07 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 917937709. At the time of this inspection, the well was equipped with a Concoyle plunger lift assembly and the annulus valve was closed but the flow line was open. The tank battery consisted of one 210 BBL production tank, a 25 BBL plastic tank and a mechanical separator. The heater tube at the base of the 210 BBL tank that was still leaking fluid from it. Salt crystals have colleced below the leak. The dike around the tank battery still has not been rebuilt. The signage located at the tank battery needed to include the phone number for the contact information.
0917937709 2016-04-20 Production Wells Violations Noted My inspection found the tank battery was equipped with one 210 barrel steel tank and one 25 barrel plastic tank. There was no emergency phone number posted on the identification sign. I took one photo of the identification sign. The heater tube at the base of the 210 barrel tank was leaking fluid from it. There was salt crystals collecting below the leak. I took one photo of the salt crystals. There was no dike around the tank battery area. The tank battery was located on a hillside above a stream. There was a chart on the gas meter with the date of 3-29-16 posted on it. The chart showed production. I took one photo of the chart. The well was equipped with a concoil unit. The valve from the well to the flow line was closed. REQUIRED REMEDIAL WORK: Empty the 210 barrel tank immediately, repair or replace the leaking tank, establish a earthen dike around the tank battery, post a emergency phone number on the identification sign.
1712581528 2005-04-13 Production Wells No Violations no violations .
412036641 2018-3-7 0:00:0 PW No Violations
87072387 2016-12-19 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0917937709 US-OH-130488 2016-05-02 Well operation causing pollution and contamination
0917937709 US-OH-130489 2016-05-02 Failure to legibly identify well
0917937709 US-OH-130490 2016-05-02 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References