X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-21926

Well Details

Well ID: 34-007-21926
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Cherry Valley Township
Operator Name: PLATEAU ENERGY CORP
Well Pad ID:
Farm/Lease Name: ENGEL LORETTA
License Status: Producing
License Date: 1992-05-28
Spud Date: 1982-01-09
Spud Drilling Contractor:
Final Drill Date: 1982-01-15
Well Total Depth: 3770.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -80.690000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1982-01-09 PERMIT EXPIRED.
Completed 1982-01-15 PERMIT EXPIRED.
Reached Total Depth 1982-01-15 PERMIT EXPIRED.
CO 1992-05-28 525 JAMES DRILLING CORP GeoDate 5/28/92
Unknown 1992-05-28 Issued Date 5/28/92 Expired Date 5/28/93 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
CO 1992-07-09 4314 BRAINARD D JAMES/BARBARA GeoDate 5/28/92
Construction Permit Expires 1993-05-28 PERMIT EXPIRED.
Change of Owner 2001-02-16 Operator changed from 4314, BRAINARD D JAMES/BARBARA to 4415, PLATEAU ENERGY CORP
Record Last Modified 2019-06-14 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3624 3626 1
2006-09-11 3625 3630 1
3624 3626 1
3624 3626 1
2006-09-11 3636 3638 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 JAMES DRILLING CORP 1162.00 0.00 0
1986 JAMES DRILLING CORP 916.00 0.00 365
1987 JAMES DRILLING CORP 661.00 0.00 365
1988 JAMES DRILLING CORP 643.00 0.00 365
1989 JAMES DRILLING CORP 0.00 474.00 365
1990 JAMES DRILLING CORP 344.00 95.00 365
1991 JAMES DRILLING CORP 99.00 0.00 365
1992 JAMES DRILLING CORP 39.00 0.00 365
2002 PLATEAU ENERGY CORP 28.00 38.00 365
2009 PLATEAU ENERGY CORP 30.00 32.00 210

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 JAMES DRILLING CORP Brine 224 0
1986 JAMES DRILLING CORP Brine 221 365
1987 JAMES DRILLING CORP Brine 144 365
1988 JAMES DRILLING CORP Brine 118 365
1989 JAMES DRILLING CORP Brine 171 365
1990 JAMES DRILLING CORP Brine 26 365
1991 JAMES DRILLING CORP Brine 48 365
1992 JAMES DRILLING CORP Brine 190 365
2002 PLATEAU ENERGY CORP Brine 0 365
2009 PLATEAU ENERGY CORP Brine 35 210

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1200611293 2020-5-6 0:00:0 PW No Violations
-1341336485 2019-2-13 0:00: PW No Violations
-1621077170 2018-2-14 0:00: PW No Violations
-672699279 2019-1-9 0:00:0 PW No Violations 0.40
0672699279 2019-01-09 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1430758834 and complaint 5667. At the time of this inspection, the well consisted of a 4.5 inch casing swaged into a 2 inch line with a regulator. The casing valve and 2 inch line off the 4.5 inch casing was open. The well is primarily used for domestic purposes on this parcel. No effort to mitigate the leaking 100 BBL tank adjacent to the well. As requested in the previous inspection reports, the disconnected 100 BBL tank needs to be removed from the site. No legible identification has been installed at the well or shared tank battery. The tank valve that was dripping brine at the 210 BBL production tank has not been repaired, no has any identification been installed at the tank battery.
1341336485 2019-02-13 Production Wells No Violations I conducted a compliance notice follow--inch ball valve that was closed. Well was disconnected from the flow line. From the top of the valve ran a one-inch steel line over to a two-inch poly line which was directed south towards another well #24213. The tank battery consists of one 100 bbl. production tank and one 210 bbl. production tank, and one vertical separator, value was shut at separator. No Proper identification was posted at the well and tank battery.
1430758834 2015-04-22 Production Wells Violations Noted Complaint# 5010, Jake Ward. My inspection of the well found there is production casing only with a domestic hook-up directly from production casing. There is a 100 bbl steel tank located fifthteen feet south of well. The tank is not connected to anything. There was a puddle of water three feet south-east of well with a small amount of oil floating on it. There was no identification posted at the well location. This well shares a common tank battery with permit# 4213. The tank battery had no identification posted for this well. The last reported production for this well was 32 bbl of oil, 30 mcf of gas and 35 bbl of brine in 2009. There is a unresolved Chiefs Order for failure to maintain liability insurance issued on 7-14-2014. REMEDIAL WORK REQUIRED TO RESOLVE VIOLATIONS: REMOVE SMALL AMOUNT OF OIL NEAR THE WELL,OBTAIN LIABILITY INSURANCE, POST IDENTIFICATION AT THE WELL AND TANK BATTERY LOCATIONS, SUBMIT PRODUCTION REPORTS FROM 2010 TO PRESENT.
1441643106 2015-07-06 Production Wells No Violations Follow-up: Complaint # 5010, Jake Ward. My inspection found there has been no action to correct the compliance issues. I attempted to contact Charles Moisio by telephone to receive no response.
1536941069 2018-09-11 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1430758834 and complaint 5667. At the time of this inspection, the well consisted of a 4.5 inch casing swaged into a 2 inch line with a regulator. The casing valve was open. The well is primarily used for domestic purposes on this parcel. I contacted Mr. Charles Moisio of Plateau Energy about the production. He stated that he is not able to produce the well because the sales lines have been shut in, and are not accessible and that this well was primarily used for domestic gas. The leaking 100 BBL tank on site, adjacent to the well has been disconnected but still needs to be removed as requested in the previous inspection report. No signage has been installed at the wellhead and is needed due to a shared tank battery. I also spoke with Mr. Moisio about removing the leaking 100 BBL tank and adding signage to the well location.
1540390453 2018-10-24 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1430758834 and complaint 5667. At the time of this inspection, the well consisted of a 4.5 inch casing swaged into a 2 inch line with a regulator. The casing valve and 2 inch line off the 4.5 inch casing was open. The well is primarily used for domestic purposes on this parcel. The leaking 100 BBL tank on site, adjacent to the well has been disconnected but still needs to be removed as requested in the previous inspection reports. The shared tank battery still had a tank valve that was dripping brine at the 210 BBL production tank. The tank battery was diked and shared with well 2-4213. No identification has been installed at the well or tank battery.
1556808788 2015-9-21 0:00: PW No Violations
1574690198 2019-11-25 0:00 PW No Violations
1621077170 2018-02-14 Production Wells No Violations I inspected this well as a follow-up to Chiefs Order #2014-202 for failure to maintain liability insurance. At the time of this inspection, there was a 4.5-inch casing with 4.5 to 2-inch reducer swage, with valve and regulator. The flow-line connection was closed. There was a 100-barrel steel stock tank located adjacent to the well, and a two-tank battery with separator located at the lease road entry point (presumed to be shared with the Brainard (#2-4213) located further south along the same access road. There were no signs of active production. There was no identifying signage. There remained no active liability insurance on file for Plateau Energy Corp.
1727900501 2017-07-12 Production Wells No Violations I conducted a compliance notice follow-up inspection from the last inspection report numbered 1441643106, and complaint 5667. At the time of this inspection, the well consisted of a 4.5 inch casing swaged into a 2 inch line with a regulator. The casing valve was open. There has been no reported production for this well since 2009. I contacted Mr. Charles Moseo of Plateau Energy about the production. He stated that he is not able to produce the well because the sales lines have been shut in, and are not accessible and that this well was primarily used for domestic gas, however the property receiving gas is currently vacant. The leaking 100 BBL tank on site, adjacent to the well has been disconnected but still needs to be removed as requested in the previous inspection report. No signage has been installed at the wellhead and is needed due to a shared tank battery. I also spoke with Mr. Moseo about removing the leaking 100 BBL tank and adding signage to the well location.
1738489748 2020-3-27 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1430758834 US-OH-112588 2015-05-21 Well operation causing pollution and contamination
1430758834 US-OH-112589 2015-05-21 Failure to legibly identify well
1430758834 US-OH-112590 2015-05-21 Failure to register/obtain or maintain bond/insurance
1430758834 US-OH-112591 2015-05-21 Statement of annual production not filed

For data sources see[9]

References