If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-007-21847 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.61,"lon":-80.78,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashtabula | |
Municipality: New Lyme Township | |
Operator Name: US ENERGY OH LLC | |
Well Pad ID: | |
Farm/Lease Name: RHOA (SWIW # 8) | |
License Status: Active Injection | |
License Date: 2013-08-20 | |
Spud Date: 1982-03-06 | |
Spud Drilling Contractor: CVAS DRLG | |
Final Drill Date: 1982-03-17 | |
Well Total Depth: 7136.00 ft | |
Configuration: Vertical | |
Latitude: 41.610000 | |
Longitude: -80.780000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1982-03-06 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
Completed | 1982-03-17 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
Reached Total Depth | 1982-03-17 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
CO | 1982-04-16 | 277 ATWOOD ENERGY INC GeoDate 6/11/82 |
Oil and Gas | 1982-06-11 | Issued Date 6/11/82 Expired Date 12/1/82 Acres 0081000 Tool Type RTAF Proposed Formation BASEMENT Proposed Depth 07105 Proposed Drill Depth 07105 |
Completion Report Received | 1983-01-31 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
CO | 1991-03-26 | 277 ATWOOD ENERGY INC GeoDate 3/26/91 |
Salt Water Injection Well | 1991-03-26 | Issued Date 3/26/91 Expired Date Acres 0081000 Tool Type NT Proposed Formation MT SIMON Proposed Depth Proposed Drill Depth |
Storage Well | 1991-03-26 | Issued Date 3/26/91 Expired Date Acres 0081000 Tool Type NT Proposed Formation MT SIMON Proposed Depth Proposed Drill Depth |
CO | 1995-08-07 | 4205 TRANSFUEL RESOURCES CO GeoDate 10/3/95 |
CO | 1995-10-03 | 53 ATWOOD RESOURCES INC GeoDate 10/3/95 |
Salt Water Injection Well | 1995-10-03 | Issued Date 10/3/95 Expired Date 10/2/96 Acres 0081000 Tool Type NT Proposed Formation MT. SIMON Proposed Depth Proposed Drill Depth |
Storage Well | 1995-10-03 | Issued Date 10/3/95 Expired Date 10/2/96 Acres 0081000 Tool Type NT Proposed Formation MT. SIMON Proposed Depth Proposed Drill Depth |
CO | 1995-10-27 | 213 LOMAK OPERATING CO GeoDate 10/3/95 |
Change of Owner | 2000-06-26 | Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2005-01-21 | Operator changed from 2026, SUMMIT PETROLEUM INC to 1966, PETROX, INC |
Change of Owner | 2005-01-21 | Operator changed from 6674, GREAT LAKES ENERGY PTNSHP LLC to 2026, SUMMIT PETROLEUM INC |
Change of Owner | 2013-06-12 | Operator changed from 1966, PETROX, INC to 9146, SHALELOGIX LLC |
APP | 2013-08-20 | Proposed Formations:ROSE RUN THRU MIT SIMON, Issued Date:8/20/2013, Expired Date:8/20/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Last Compliance Report | 2014-05-06 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
Construction Permit Expires | 2015-08-20 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
Record Last Modified | 2018-03-02 | SWDW #8 CONVERT 6-11-82, CONVERT 10-7-95, CONVERT 3-30-91, NOTE INFORMATION ON BACK PF=CAMBRO-ORD. PERMITTED TO CONVERT TO SWIW - 8/20/2013 - TET |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-02-13 | 6148 | 6168 | 40 |
2014-02-13 | 6214 | 7108 | 735 |
6148 | 6168 | 40 | |
6214 | 7108 | 735 | |
6148 | 6168 | 40 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | NONE |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | TRANSFUEL RESOURCES CO | 0.00 | 0.00 | 270 |
2005 | PETROX, INC | 194.00 | 0.00 | 365 |
2006 | PETROX, INC | 289.00 | 20.00 | 365 |
2007 | PETROX, INC | 284.00 | 55.00 | 365 |
2008 | PETROX, INC | 271.00 | 19.00 | 365 |
2009 | PETROX, INC | 1047.00 | 25.00 | 365 |
2010 | PETROX, INC | 754.00 | 21.00 | 365 |
2011 | PETROX, INC | 511.00 | 21.00 | 365 |
2012 | PETROX, INC | 45.00 | 0.00 | 366 |
2013 | PETROX, INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | TRANSFUEL RESOURCES CO | Brine | 0 | 270 |
2005 | PETROX, INC | Brine | 75 | 365 |
2006 | PETROX, INC | Brine | 78 | 365 |
2007 | PETROX, INC | Brine | 365 | |
2008 | PETROX, INC | Brine | 32 | 365 |
2009 | PETROX, INC | Brine | 28 | 365 |
2010 | PETROX, INC | Brine | 42 | 365 |
2011 | PETROX, INC | Brine | 46 | 365 |
2012 | PETROX, INC | Brine | 0 | 366 |
2013 | PETROX, INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1000724517 | 2018-8-27 0:00: | SW | No Violations | 0.40 |
-1144096996 | 2019-2-4 0:00:0 | SW | No Violations | 1.00 |
-1186424971 | 2018-3-16 0:00: | SW | No Violations | 6.00 |
-1279822055 | 2014-2-25 0:00: | SW | No Violations | |
-1292564859 | 2017-11-8 0:00: | SW | No Violations | 0.70 |
-1524170920 | 2019-4-19 0:00: | SW | No Violations | 0.50 |
-1573659687 | 2020-8-5 0:00:0 | SW | No Violations | |
-1574243211 | 2017-9-21 0:00: | SW | No Violations | 0.50 |
-166717727 | 2016-3-29 0:00: | SW | No Violations | |
-1705606618 | 2018-11-5 0:00: | SW | No Violations | 0.50 |
-1759090781 | 2017-9-21 0:00: | SW | No Violations | 1.20 |
-1814051939 | 2019-6-12 0:00: | SW | No Violations | 0.50 |
-199990525 | 2008-6-19 0:00: | PW | No Violations | |
-2084989385 | 2015-10-7 0:00: | SW | No Violations | |
-271236615 | 2007-11-5 0:00: | PW | No Violations | |
-314034496 | 2014-6-3 0:00:0 | SW | No Violations | |
-448981211 | 2018-7-18 0:00: | SW | No Violations | 0.80 |
-489317457 | 2018-12-6 0:00: | SW | No Violations | 1.50 |
-879481889 | 2020-5-14 0:00: | SW | No Violations | 1.00 |
-998077786 | 2020-1-15 0:00: | SW | No Violations | 0.80 |
0150359544 | 2014-11-26 | Salt Water Injection Well | No Violations | My inspection of the well pressures and the storage facility found no compliance issues. |
0166717727 | 2016-03-29 | Salt Water Injection Well | No Violations | My inspection of the well pressures and the storage facility found no compliance issues with this well. |
0199990525 | 2008-06-19 | Production Wells | No Violations | no violations . |
0220431681 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
0271236615 | 2007-11-05 | Production Wells | No Violations | no violations . |
0293689266 | 2015-03-05 | Salt Water Injection Well | No Violations | My inspection of the storage facility and the well pressures found no compliance issues. |
0314034496 | 2014-06-03 | Salt Water Injection Well | No Violations | I was on location with supervisor Tom Hill. The off loading pad and tank battery are in good repair. The tank battery consists of 12 400 BBL fiberglass tanks and a 100 BBL steel tank. The well was operating while we were on location. The injection pressure on the tubing was 760 psi. No violations were found during our inspection. |
0315617249 | 2018-03-15 | Salt Water Injection Well | No Violations | I was on location to witness Nicks Well Plugging (NWP) remove the tubing and packer from the well. NWP removed the rest of the tubing and packer. NWP shipped the packer to Baker Hughes to be rebuilt. Sutton Pump and Supply pressure tested the tubing; no holes or defects were detected. |
0333674265 | 2018-10-26 | Salt Water Injection Well | No Violations | I found the injection well operating on the day of my inspection. Identification signs are posted. There was a facility operator on location. There is a steel dike with two (2) frac tanks next to the main diked tank battery with several inches of water with oil. I observed no spills or leaks in the main steel dike or pump house. I instructed the facility operator to remove all of the oil from the second steel dike. A follow-up inspection will be conducted by November 2, 2018. |
0335750358 | 2014-05-09 | Salt Water Injection Well | No Violations | My inspection of the well pressures and the storage facility found no violations . |
0448981211 | 2018-07-18 | Salt Water Injection Well | No Violations | I found the injection well operating on the day of my inspection. Identification signs are posted. I observed small amount of oil residue contained in the dike at the base of the southern most storage tank. I informed the facility operator to clean-up the oil. |
0489317457 | 2018-12-06 | Salt Water Injection Well | No Violations | I found the injection well operating on the day of my inspection. There was a facility operator on location. I observed approximately 4 inches of water with a small amount of oil in the secondary diked tank battery with the two (2) frac tanks. The small amount of oil was isolated to the northeast corner of the dike. The facility operator stated they are working on pumping the water and oil into a storage tank; however, hose on the sump pump keeps freezing. There are some small pools of water in the primary diked tank battery from the recent weather conditions. Identification signs are posted. There was a Hall Excavating brine truck on location with the proper UIC number and company information displayed (#25-624). |
0623273666 | 2018-06-11 | Salt Water Injection Well | No Violations | I found the injection well in operation. There was a facility operator on location. Identification signs are posted. I observed no leaks or spills. There are no violations at this time. |
0666882514 | 2015-12-31 | Salt Water Injection Well | No Violations | Inspection of the well pressures and the storage facility found no compliance issues with this well. |
1000724517 | 2018-08-27 | Salt Water Injection Well | No Violations | I found the injection well in operation during my inspection. There are identification signs posted. The needle valve coming off of the annulus was difficult to open and closed. I observed no leaks or spill outside of the steel diked tank battery. There was a facility operator on location. I told the facility operator to replace the needle valve the next inspection. |
1149465508 | 2019-12-4 0:00: | SW | No Violations | 1.40 |
1186424971 | 2018-03-16 | Salt Water Injection Well | No Violations | I, along with Supervisor Steve Ochs, were on location to witness activities associated with installation of down-hole packer and mechanical integrity test. During our visit crews from Nicks Well Plugging installed the re-furbished packer (make) with pull-off joint, which was set at 6,082 feet. Approximately 10 gallons of packer inhibitor was mixed with 100 barrels of fresh water and circulated. The packer was pressured up to 1,475 PSI and held for 15 minutes with no appreciable loss of pressure. |
1279822055 | 2014-02-25 | Salt Water Injection Well | No Violations | My inspection of the well pressures and the storage facility I found no violations . |
1292564859 | 2017-11-08 | Salt Water Injection Well | No Violations | I found the UIC facility in good repair on the day of my inspection. Facility operator was not on location and the injection well was not in operating. The pump house is locked and secure. The storage tanks are set in a steel dike. I observed no leaks or spill. The proper identification is posted. There were two (2) brine trucks from Castelli Oil & Gas Services and R.R. Dean Oilfield Services on location with the proper UIC brine numbers (#423 and #621) There are no violations at this time. |
1392227029 | 2014-01-17 | Salt Water Injection Well | No Violations | I was on site to pressure test the flowline from the pump house to the wellhead . Company pressured up to 1750 psi and held the pressure for 15 minutes with no loss of pressure . The test passed . |
1431705031 | 2015-05-07 | Salt Water Injection Well | No Violations | My inspection of the well pressures and the storage facility found no compliance issues. |
1438781832 | 2015-07-31 | Salt Water Injection Well | No Violations | Well was running at the time of inspection. Operator has installed two 500BBL frac tanks east of the main tank battery, since my last inspection. Tank battery was in good repair, unloading pad was clean and the facility in general was clean and organized. Two loads of brine were delivered during the time that I was on location. Brine was brought in by UIC 25-564. |
1473269203 | 2016-06-22 | Salt Water Injection Well | No Violations | My inspection of the well pressures and the storage facility found no compliance issues. |
1502633216 | 2014-08-29 | Salt Water Injection Well | No Violations | Inspection of the well pressures and the storage found no violations. |
150359544 | 2014-11-26 0:00 | SW | No Violations | |
1516378712 | 2018-01-19 | Salt Water Injection Well | No Violations | I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted. There are no violations at this time. |
1521122144 | 2018-03-14 | Salt Water Injection Well | No Violations | I was on location to witness Nicks Well Plugging (NWP) remove the tubing and packer from the well. Jason Nicholas from Shalelogix, stated the packer may be leaking or there may be a hole. A Baker Hughes representative was on location to assist NWP remove the packer. By the end of the day, NWP achieved releasing the set packer and removed half of the tubing. The wellhead was shut-in for the night. |
1541171026 | 2019-9-11 0:00: | SW | No Violations | 0.60 |
1560866877 | 2019-6-18 0:00: | SW | No Violations | 2.20 |
1562680496 | 2019-7-9 0:00:0 | SW | No Violations | 2.30 |
1574243211 | 2017-09-21 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. There are identification signs posted on the pump house, access road entrance, and at the injection well. The tank battery consists of a lined steel dike with 13 storage tanks. There are no violations at this time. |
1587653771 | 2020-4-23 0:00: | SW | No Violations | 2.30 |
1705606618 | 2018-11-05 | Salt Water Injection Well | No Violations | I found Shalelogic has removed most of the water and oil from the second steel diked tank battery. There is a small amount of water and oil in the northwest corner of the dike. I spoke with the facility operator on location. The facility operator stated the company is in the process of cleaning out the sump pit in the northwest corner in order to final removing the remaining amount of water and oil. While on location, a CES (#25-423) and R. R. Dean Oil Field Services (#25-621) brine trucks arrived on location with the proper UIC number displayed. |
1759090781 | 2017-09-21 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. I found the UIC facility in good repair. There is a steel dike around the storage tanks. There are identification signs posted. There are no violations at this time. |
1816392280 | 2019-5-16 0:00: | SW | No Violations | 2.30 |
1940451168 | 2016-11-07 | Salt Water Injection Well | No Violations | Inspection of the storage facility and the well pressures found no compliance issues. |
2084989385 | 2015-10-07 | Salt Water Injection Well | No Violations | Inspection of the well pressures and the storage facility found no compliance issues with this well. |
2123991597 | 2017-03-31 | Salt Water Injection Well | No Violations | My inspection of the storage facility and the well pressures found no compliance issues. |
2139721701 | 2019-5-24 0:00: | SW | No Violations | 1.10 |
220431681 | 2019-4-29 0:00: | SW | No Violations | |
293689266 | 2015-3-5 0:00:0 | SW | No Violations | |
315617249 | 2018-3-15 0:00: | SW | No Violations | 7.50 |
333674265 | 2018-10-26 0:00 | SW | No Violations | 0.50 |
335750358 | 2014-5-9 0:00:0 | SW | No Violations | |
337940326 | 2019-7-1 0:00:0 | SW | No Violations | 1.00 |
623273666 | 2018-6-11 0:00: | SW | No Violations | 0.40 |
666882514 | 2015-12-31 0:00 | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0220431681 | US-OH-122194 | 2019-05-09 | Failure to file salt water injection annual report |
For data sources see[9]