34-007-20600

Well Details

Well ID: 34-007-20600
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Monroe Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: KOROSY UNIT
License Status: Producing
License Date: 1973-10-24
Spud Date: 1974-01-31
Spud Drilling Contractor:
Final Drill Date: 1975-01-20
Well Total Depth: 3291.00 ft
Configuration: Vertical
Latitude: 41.840000
Longitude: -80.620000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1973-10-24 300 PETROLEUM ENERGY PROD COR GeoDate 10/24/73
Oil and Gas 1973-10-24 Issued Date 10/24/73 Expired Date Acres 0052000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1974-01-31
Completed 1975-01-20
Reached Total Depth 1975-01-20
Completion Report Received 1975-02-12
CO 1991-10-09 201 GREEN GAS CO GeoDate 10/24/73
CO 1992-04-08 1453 GREEN ENERGY INC GeoDate 10/24/73
Change of Owner 2001-02-06 Operator changed from 1453, GREEN ENERGY INC to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3089 3148 59
3089 3148 59
3089 3148 59

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1525 Bbl 41000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EVERFLOW EASTERN PARTNERS LP 125.00 0.00 214
1987 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1988 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1989 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1990 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1991 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1992 GREEN ENERGY INC 763.00 38.00 365
1993 GREEN ENERGY INC 482.00 15.00 365
1994 GREEN ENERGY INC 408.00 0.00 365
1995 GREEN ENERGY INC 335.00 0.00 365
1996 GREEN ENERGY INC 195.00 0.00 365
1997 GREEN ENERGY INC 291.00 0.00 365
1998 GREEN ENERGY INC 208.00 62.00 365
1999 GREEN ENERGY INC 159.00 0.00 365
2000 GREEN ENERGY INC 205.00 30.00 365
2001 BIG SKY ENERGY INC 654.00 0.00 365
2002 BIG SKY ENERGY INC 344.00 0.00 365
2003 BIG SKY ENERGY INC 340.00 0.00 365
2004 BIG SKY ENERGY INC 476.00 89.00 365
2005 BIG SKY ENERGY INC 166.00 21.00 365
2006 BIG SKY ENERGY INC 24.00 0.00 365
2007 BIG SKY ENERGY INC 15.00 0.00 365
2008 BIG SKY ENERGY INC 7.00 0.00 365
2009 BIG SKY ENERGY INC 4.00 0.00 365
2010 BIG SKY ENERGY INC 4.00 26.00 365
2011 BIG SKY ENERGY INC 0.00 0.00 365
2012 BIG SKY ENERGY INC 37.00 0.00 366
2013 BIG SKY ENERGY INC 198.00 0.00 250
2014 BIG SKY ENERGY INC 0.00 26.00 365
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EVERFLOW EASTERN PARTNERS LP Brine 75 214
1987 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1988 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1989 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1990 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1991 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1992 GREEN ENERGY INC Brine 478 365
1993 GREEN ENERGY INC Brine 239 365
1994 GREEN ENERGY INC Brine 0 365
1995 GREEN ENERGY INC Brine 0 365
1996 GREEN ENERGY INC Brine 0 365
1997 GREEN ENERGY INC Brine 249 365
1998 GREEN ENERGY INC Brine 490 365
1999 GREEN ENERGY INC Brine 237 365
2000 GREEN ENERGY INC Brine 191 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 250
2014 BIG SKY ENERGY INC Brine 201 365
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1132188715 2006-1-26 0:00: PW No Violations
-1223028123 2015-12-2 0:00: PW No Violations
-1310711158 2016-9-27 0:00: PW No Violations
-1393950704 2020-1-10 0:00: PW No Violations
-1436418156 2016-12-22 0:00 PW No Violations
-1436581461 2015-8-18 0:00: PW No Violations 0.50
-173257310 2018-5-15 0:00: PW No Violations 1.00
-1813297033 2014-4-28 0:00: PW No Violations
-1988451905 2017-10-30 0:00 PW No Violations 1.00
-205229564 2016-2-5 0:00:0 PW No Violations
0033146088 2015-07-10 Production Wells Violations Noted My inspection of this well found the tank battery area is overgrown with 8-9 foot tall fragmite grass. There is no identification posted at the tank battery area. While walking to the well location I come across a active gas leak 200 feet south of the tank battery. At the well I found fresh oil and paraffin on the ground around the well casing in a area two feet by eight feet. I spoke to Brian the well tender and told him of the gas leak. REMEDIAL WORK REQUIRED TO RESOLVE THE VIOLATIONS: REPAIR THE GAS LEAK, REMOVE ALL OIL AND PARAFFIN ON THE GROUND AROUND THE WELL, ESTABLISH IDENTIFICATION AT THE TANK BATTERY AREA.
0173257310 2018-05-15 Production Wells No Violations I inspected this well pursuant to open compliance deficiencies. At the time of this inspection, I noted the following: a wellhead with pump jack system in a clearing in an otherwise wooded area. The pump was idle. There was residual oil from a previous leak at the wellhead that remained. There was gas leaking from the stuffing box fitting. The overhead electric line for the pump jack system was laying on the ground, having been struck by falling branches. The power supply had been disconnected. The associated tank battery was comprised of one 210-barrel production tank, and horizontal separator. The tank was empty. The secondary containment was mostly overgrown with vegetation, but was free from signs of spills, or leaks. There were no signs that the well was being produced. There was a chart recorder that was not active. The access road to the well was heavily overgrown and passable by foot only. The battery appears to be shared with the Korosy #2. There was an active domestic tie-in at the Korosy #2 (#2--0616) wellhead.
0205229564 2016-02-05 Production Wells No Violations My inspection found the pollution at the well location has not been remediated. There has been no identification posted for this well.
1118613377 2015-10-29 Production Wells No Violations My inspection found the gas leak has been repaired. The oil and paraffin saturated soil has not been removed from around the well location. There was no identification posted at the tank battery location.
1132080293 2018-03-06 UrbanProduction Wells No Violations I inspected this well pursuant to Chiefs Order #2016-300 issued for lack of insurance. The well and associated battery are located on a rural farm parcel. At the time of this inspection, I noted the following: a wellhead with pump jack system in a clearing in an otherwise wooded area. The pump was idle. There was residual oil from a previous leak at the wellhead that remained. The associated tank battery was comprised of one 210-barrel production tank, and horizontal separator. The tank was empty. The secondary containment was mostly overgrown with vegetation, but was free from signs of spills, or leaks. There were no signs that the well was being produced. There was a chart recorder that was not active. The access road to the well was heavily overgrown and passable by foot only.
1132188715 2006-01-26 Production Wells No Violations no violations .
1223028123 2015-12-02 Production Wells No Violations I conducted a compliance follow-up inspection on this well. The oil/paraffin saturated soil has been removed from site. The signage still needs added at the tank battery. No new violations were observed during this inspection.
1310711158 2016-09-27 Production Wells No Violations My inspection of this well found there was no identification posted at the tank battery location. The oil and paraffin around the well has not been removed.
1384940342 2020-8-24 0:00: PW No Violations
1436418156 2016-12-22 Production Wells No Violations My inspection of this well found there has been no action from the company to remove the contaminated soil at the well site area or post identification for this well.
1436581461 2015-08-18 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 33146088. During my inspection, I found the tank battery overgrown with 8-9 phragmites. There is a pathway to the mechanical separator. There is no identification posted. I observed fresh oil and paraffin on the wellhead and on the ground in a 2 x 8 area. Photos were taken and are available upon request.
1813297033 2014-04-28 Production Wells No Violations I inspected this well to determine if the company is in compliance with Chiefs order # 2014-43 . Upon my inspection I found the chart on the gas meter displayed the date of 4-23-2014 . The chart also indicated this well is in production . While walking to the well location I come across a gas leak in the flow line about 200 south of the tank battery on the west side of the lease road . There is also fresh oil about 6 in diameter around the gas leak location . Further inspection of the well found fresh oil lying on the ground around the wellhead and fresh oil lying on water about 70 south of well location . I immediately contacted Bob Barr Jr. by telephone and told him of the gas leak and the oil spill at the well location . Bob told me he would have someone come out as soon as possible to address the compliance issues . Also there is not a legible identification sign posted at the tank battery location . This well is not in compliance with Chiefs order # 2014-43 . .
1988451905 2017-10-30 Production Wells No Violations oil around pump jack still needs cleaned up. Access road to well is heavily overgrown. I inspected this well location as part of legal proceedings. As such, the following deficiencies had been noted: leakage of oil at the wellhead, and lack of identifying signage. At the time of this inspection, I noted the following: a wellhead with pump jack system and associated battery on a larger, rural parcel. The battery was comprised of one 210-barrel, steel production tank and horizontal separator. Fittings and connections at the both the well head and battery were secure but prior leakage of oil around the base of the wellhead remained. ID signage was present but not complete (lacking complete API permit #). The access road to the well was heavily overgrown with vegetation, as well as the areas surrounding the battery.
2098987310 2016-03-18 Production Wells No Violations I was accompanied by Jen Barret, Dan Martin, Mike Williams [ Attorney generals Office ], Rick Anderson and Tom Hill [ ODNR Division of Oil & Gas ]. There has been no further clean-up of the pollution at the well site area since my last inspection on 2-5-2016.
33146088 2015-7-10 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0033146088 US-OH-123472 2015-07-15 Inadequate pipeline strength
0033146088 US-OH-123473 2015-07-15 Well operation causing pollution and contamination
0033146088 US-OH-123474 2015-07-15 Failure to legibly identify well

For data sources see[9]

References