X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-23962

Well Details

Well ID: 34-005-23962
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Lake Township
Operator Name: LINDENS PROPANE INC
Well Pad ID:
Farm/Lease Name: SNYDER BEULAH B
License Status: Domestic Well
License Date: 1992-11-16
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1944-09-02
Well Total Depth: 2966.00 ft
Configuration: Vertical
Latitude: 40.690000
Longitude: -82.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1944-09-02 PERMIT EXPIRED. FD & PF=2ND
Reached Total Depth 1944-09-02 PERMIT EXPIRED. FD & PF=2ND
CO 1992-11-16 627 KENOIL GeoDate 11/16/92
Unknown 1992-11-16 Issued Date 11/16/92 Expired Date 11/16/93 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date
Construction Permit Expires 1993-11-16 PERMIT EXPIRED. FD & PF=2ND
Record Last Modified 2013-05-23 PERMIT EXPIRED. FD & PF=2ND

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 40 Qts 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 KENOIL LLC 956.00 41.00 0
1985 KENOIL LLC 1637.00 151.00 0
1986 KENOIL LLC 548.00 217.00 365
1987 KENOIL LLC 492.00 225.00 365
1988 KENOIL LLC 378.00 148.00 365
1989 KENOIL LLC 484.00 0.00 365
1990 KENOIL LLC 124.00 55.00 365
1991 KENOIL LLC 0.00 39.00 365
1992 KENOIL LLC 0.00 40.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 KENOIL LLC Brine 0 0
1985 KENOIL LLC Brine 3 0
1986 KENOIL LLC Brine 0 365
1987 KENOIL LLC Brine 0 365
1988 KENOIL LLC Brine 0 365
1989 KENOIL LLC Brine 0 365
1990 KENOIL LLC Brine 8 365
1991 KENOIL LLC Brine 0 365
1992 KENOIL LLC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-715743531 2020-5-5 0:00:0 PW No Violations
0290854311 2014-02-03 Production Wells No Violations There is no ID on the well or tanks. There are 2 100 Bbl tanks at the location but only one is connected to the well.
1519410805 2018-02-23 Production Wells Violations Noted The well is equipped with a pump jack, rods and tubing and is in production. There is a 100 barrel tank, separator and drip bottle connected to the well. The tank incorrectly identifies the well owner as American Augers. No other identification is posted. There is a burn pile located adjacent to the drip bottle which needs to be moved away from the pipeline equipment. Lindens Propane was contacted and they stated they own no property in Loudonville and that Holly Linden is the responsible party for the well. Holly did not respond to a phone call or voicemail message. Identification needs to be posted at the well and the registration needs to be properly transferred to reflect well ownership.
1540297760 2018-10-22 Production Wells No Violations The well is equipped with a pump jack, rods, and tubing and is in production. The well remains unidentified and registered to Lindens Propane. The property owner is still working on transferring the well. The resident on the farm arrived during inspection and stated she had identification to post at the well and would get that taken care of. They are working with a contractor to remove the old separator equipment from the pipeline.
1557142529 2019-04-17 Production Wells No Violations Inspected well on 04/17/2019 to follow-up on a previously-issued compliance notice. The well is equipped with a pump jack with an electric motor, and 1-100 bbl steel tank located within an earthen dike. An additional 100 bbl steel tank (empty and not in-use) is located ~50 away from the diked area. Well identification is clearly displayed at the tank batery. Contacted Kathryn Smith (DOGRM Columbus) to discover issued preventing the well transfer from proceeding, and also requested a new well transfer paperwork packet be sent to Ms. Linden. The issues discussed with DOGRM Columbus were discussed with Ms. Holly Linden, who will follow-up with Kathryn Smith. A 60-day extension to the compliance notice was granted to allow Ms. Linden time to submit the proper paperwork. No other problems were noted at the time of the inspection.
1588682074 2020-5-5 0:00:0 PW No Violations 45.00
1681665205 2018-05-03 Production Wells No Violations The well remains registered to Lindens Propane. Holly Linden was contacted and stated she is working on transferring the well registration and has sent an application to the Divisions registration office but they requested additional information and she now has an attorney working on gathering ownership records. ID has not been posted at the well. Gas is detectable around the condensate drip and is audibly leaking from it. The debris pile and burn pit have not been moved away from the separator and drip. Holly stated she would send someone to check the drip and stop the leak.
290854311 2014-2-3 0:00:0 PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1519410805 US-OH-114438 2018-03-08 9-9-02 General Safety
1519410805 US-OH-114439 2018-03-08 9-9-05(A)10 Failure to legibly identify well
1519410805 US-OH-114440 2018-03-08 NONEH Failure to notify MRM of assignment or transfer of wells

For data sources see[8]

References