Well Details

Well ID: 34-005-23746
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: BRETTIN
License Status: Active Injection
License Date: 1984-08-14
Spud Date: 1984-09-05
Spud Drilling Contractor: WALTZ BROS DRLG
Final Drill Date: 1984-09-06
Well Total Depth: 817.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -82.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-08-14 133 QUAKER STATE OIL REF CORP GeoDate 8/14/84
Enhanced Recovery 1984-08-14 Issued Date 8/14/84 Expired Date 2/10/85 Acres 0080000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00817 Proposed Drill Depth 00817
Original Spud 1984-09-05
Completed 1984-09-06
Reached Total Depth 1984-09-06
First Injection 1984-12-06
Completion Report Received 1985-01-14
Construction Permit Expires 1985-02-10
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 8/14/84
Annulus Pressure Monitoring Approved 1998-12-03
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Last Compliance Report 2014-08-19
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-23 708 750 0
2006-09-11 712 742 0
708 750 0
712 742 0
708 750 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 60 Qts 0 LOGS ATTACHED; PRODUCTION ZONE SHOT WITH NITRO AS WELL

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1032976358 2011-7-12 0:00: ER No Violations
-1110550567 2020-7-9 0:00:0 ER No Violations
-1139200250 2010-11-26 0:00 ER No Violations 0.50
-1163721403 2008-11-25 0:00 ER No Violations 0.50
-1193961381 2014-7-17 0:00: ER No Violations
-125486973 2014-5-6 0:00:0 ER No Violations
-1342314241 2018-4-23 0:00: ER No Violations
-153613541 2015-8-28 0:00: ER No Violations
-1543892739 2016-4-19 0:00: ER No Violations
-1657067118 2011-10-17 0:00 ER No Violations
-165788090 2004-11-18 0:00 ER No Violations
-1703265447 2019-4-11 0:00: ER No Violations
-1826525641 2014-3-18 0:00: ER No Violations
-1904440042 2008-2-15 0:00: ER No Violations 0.50
-2001980776 2019-7-2 0:00:0 ER No Violations
-2012285146 2012-9-20 0:00: ER No Violations
-2069294925 2016-7-11 0:00: ER No Violations
-2088581732 2020-4-10 0:00: ER No Violations
-210342062 2013-5-22 0:00: ER No Violations
-234863441 2012-11-27 0:00 ER No Violations
-242951420 2014-8-14 0:00: WR No Violations
-256874402 2017-4-13 0:00: ER No Violations
-293211438 2012-6-4 0:00:0 ER No Violations
-529343098 2018-8-13 0:00: ER No Violations
-596126068 2020-1-22 0:00: ER No Violations
-867911420 2018-1-8 0:00:0 ER No Violations
-958608058 2005-4-28 0:00: ER No Violations 0.50
0098810402 2015-05-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0122189748 2013-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Pump shut down during inspection.
0125486973 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well annulus has equalized with the tubing. Shut in well. The main shut off valve has a slow leak. This well will be pressure tested for integrity.
0153613541 2015-08-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Monitor the injection line fittings. The integrity is currently intact, the fittings are showing signs of deterioration.
0165788090 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
0179173639 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0210342062 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0234863441 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0242951420 2014-08-14 Work Over Reconditioning No Violations The operator installed a rebuilt Parmaco one inch packer, fabricated by Ed and 25 joints of 25 foot long of one inch PVC lined tubing. The packer was set at 625 feet. Water with inhibitor was circulated to the surface in the annular space. The well was then pressured up to 395 psi and tested for 15 minutes. The pressure loss was within the 5 percent margin. The well passes the integrity test and allowed to be put into injection production.
0256874402 2017-04-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0282957793 2009-04-27 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0293211438 2012-06-04 Enhanced Recovery Project No Violations Inspect Well.
0529343098 2018-08-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0670230583 2016-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0737717014 2009-09-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0867911420 2018-01-08 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0884817510 2015-03-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0958608058 2005-04-28 Enhanced Recovery Project No Violations Injection well test.
1032976358 2011-07-12 Enhanced Recovery Project No Violations Inspect well.
1036991360 2016-11-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well was shut in at time of inspection. The tubing is in poor condition.
1068745391 2003-08-14 Enhanced Recovery Project No Violations
1133376114 2005-11-29 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1139200250 2010-11-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1163721403 2008-11-25 Enhanced Recovery Project No Violations Injection and annulus pressure test. Needs new box lid and ID.
1193922157 2007-11-01 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1193961381 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is shut in. Tubing is removed from well. Waiting on a packer to be manufactured.
122189748 2013-12-4 0:00: ER No Violations
1342314241 2018-04-23 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1395669751 2007-05-31 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1397627568 2012-02-06 Enhanced Recovery Project No Violations Inspect Well.
1401281605 2014-05-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Pressure test annulus on well. Attempt to pressure up to 400 psi. Pressure did not hold and dropped. Tubing has failed. Shut well in for repair.
1453135685 2011-04-12 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1498012517 2017-01-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1543892739 2016-04-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1546890295 2019-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1561873394 2017-07-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1608340228 2019-11-15 0:00 ER No Violations
1618446851 2015-10-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well head is ok.
1619641861 2006-12-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1622788691 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
1651273402 2006-04-06 Enhanced Recovery Project No Violations Injection and annulus pressure test. Constructed with 2 tubing cemented at Berea cap with 1 tubing on a packer.
1657067118 2011-10-17 Enhanced Recovery Project No Violations Inspect well.
179173639 2014-10-28 0:00 ER No Violations
1826525641 2014-03-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1874932495 2013-03-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1904440042 2008-02-15 Enhanced Recovery Project No Violations Annulus and injection pressure test.
1984105548 2017-10-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2012285146 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
2023191616 2010-03-30 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2032999797 2018-10-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2069294925 2016-07-11 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The operator was notified and repaired a leaking nipple on the injection line.
282957793 2009-4-27 0:00: ER No Violations 0.50
670230583 2016-1-4 0:00:0 ER No Violations
737717014 2009-9-23 0:00: ER No Violations 0.50
884817510 2015-3-31 0:00: ER No Violations
98810402 2015-5-20 0:00: ER No Violations

For data sources see[5]