34-005-23067

Well Details

Well ID: 34-005-23067
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: MANN GLADYS C
License Status: Active Injection
License Date: 1975-03-18
Spud Date: 1975-04-08
Spud Drilling Contractor:
Final Drill Date: 1975-04-12
Well Total Depth: 691.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -82.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1975-03-18 133 QUAKER STATE OIL REF CORP GeoDate 3/18/75
Enhanced Recovery 1975-03-18 Issued Date 3/18/75 Expired Date Acres 0000000 Tool Type RTAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1975-04-08 DRILLED BY KLAEGER AND BLODGETT RE-ISSUE & SEC. REC. 3-19-75
Completed 1975-04-12 DRILLED BY KLAEGER AND BLODGETT RE-ISSUE & SEC. REC. 3-19-75
Reached Total Depth 1975-04-12 DRILLED BY KLAEGER AND BLODGETT RE-ISSUE & SEC. REC. 3-19-75
Annulus Pressure Monitoring Approved 1994-06-21 DRILLED BY KLAEGER AND BLODGETT RE-ISSUE & SEC. REC. 3-19-75
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 3/18/75
Last Compliance Report 1999-10-18 DRILLED BY KLAEGER AND BLODGETT RE-ISSUE & SEC. REC. 3-19-75
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-02-15 DRILLED BY KLAEGER AND BLODGETT RE-ISSUE & SEC. REC. 3-19-75

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-22 576 602 0
576 602 0
576 602 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 39 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC 0.00 13.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1013874021 2019-1-14 0:00: ER No Violations
-107567962 2006-3-15 0:00: ER No Violations 0.50
-1099081925 2014-5-6 0:00:0 ER No Violations
-1231867415 2015-10-6 0:00: ER No Violations
-1276546771 2020-2-24 0:00: ER No Violations
-146720455 2011-4-13 0:00: ER No Violations 0.50
-1471117343 2018-5-2 0:00:0 ER No Violations
-1487801322 2015-8-31 0:00: ER No Violations
-1568272996 2015-9-23 0:00: ER No Violations
-1715882665 2012-9-11 0:00: ER No Violations
-1753163738 2012-12-4 0:00: ER No Violations
-1847312973 2019-4-18 0:00: ER No Violations
-1859074228 2014-10-28 0:00 ER No Violations
-1924098789 2017-7-31 0:00: ER No Violations
-1930732399 2007-1-31 0:00: ER No Violations 0.50
-1936349865 2008-12-12 0:00 ER No Violations 1.00
-1945272411 2013-3-4 0:00:0 ER No Violations
-274745348 2006-1-25 0:00: ER No Violations 0.50
-413371703 2019-10-23 0:00 ER No Violations
-589933272 2011-7-12 0:00: ER No Violations
-695217903 2007-3-30 0:00: ER No Violations 1.00
-741876189 2015-3-31 0:00: ER No Violations
-745863528 2012-6-4 0:00:0 ER No Violations
-772352034 2013-10-29 0:00 ER No Violations
-911666155 2014-7-17 0:00: ER No Violations
-939570672 2018-8-20 0:00: ER No Violations
0107567962 2006-03-15 Enhanced Recovery Project Violations Noted Tested annulus and injection pressures. NOV in compliance Sun, 30 degrees.
0146720455 2011-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0236759038 2016-07-11 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head fittings have been repaired recently. The tubing is in poor condition.
0262829025 2007-10-12 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equalized at 330 psi. Suspend operation until packer is reset and tested.
0274745348 2006-01-25 Enhanced Recovery Project Violations Noted Pressures remain equalized at 350 psi. Advised Len Rex to shut in well until packer is reset. Snow, 30 degrees.
0481762512 2017-01-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0514951239 2008-12-11 Enhanced Recovery Project No Violations Injection and annulus pressure test. Pump annulus to 200 psi and test for 15 minutes.
0589933272 2011-07-12 Enhanced Recovery Project No Violations Inspect well.
0695217903 2007-03-30 Enhanced Recovery Project Violations Noted Annulus and injection pressure test. Pressures are equalized at 350 psi. Shut in well until 1 packer is repaired.
0741876189 2015-03-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0745863528 2012-06-04 Enhanced Recovery Project No Violations Inspect Well.
0756016797 2007-04-03 Enhanced Recovery Project No Violations Annulus test. Blew down annulus and pumped to 270 psi. 0% decline in 15 minutes. NOV in compliance.
0772352034 2013-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0795597986 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0870297015 2016-11-07 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Notified the operator the flow line fittings are in poor condition.
0891080424 2018-10-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0911666155 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is required to be pressure tested. Well head has a slight leak.
0939570672 2018-08-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1046510136 2011-10-17 Enhanced Recovery Project No Violations Inspect well.
1072030902 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test. Annular and tubing pressure are equalized. Advised Len Rex to repressure annulus and test. Send results to Tom Tomastik.
1099081925 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1116356387 2005-05-17 Enhanced Recovery Project No Violations Injection well test. GPS location and update to RBDMS.
1133972805 2005-12-01 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures equalized at 350 psi.
1142515312 2006-03-15 Enhanced Recovery Project No Violations Re- tested annulus and injection pressures. Nov in compliance. Sun, wind, 35 degrees.
1152692560 2018-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1167403021 2006-12-29 Enhanced Recovery Project No Violations Follow up to NOV.Ran mini test on annulus and pressures remain equal at 350 psi.One inch packer needs reset.
1194472729 2007-11-07 Enhanced Recovery Project No Violations Replaced packer and tubing and tested. NOV in compliance.
1206638593 2008-03-27 Enhanced Recovery Project No Violations Annulus and injection pressure test.
1231867415 2015-10-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Operator replaced well head fittings and updated the identification. Well is in compliance.
1240662466 2009-04-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1241732894 2007-10-22 Enhanced Recovery Project No Violations Reset packer and tested at 330psi. Presures equilized. Recommend pulling 1 packer and inspect.
1346561097 2017-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1380112669 2012-02-27 Enhanced Recovery Project No Violations inspect well. Shut in well, injector valve is beginning to leak. Will replace valve.
1424254146 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
1432899330 2015-05-21 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Injection line nipple is leaking. Annulus has pressure up from previous test. Pressure test of well is requested.
1449401264 2016-01-07 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The nipple and the Tee had a slow leak. Notified operator and Well head fitting were replaced.
1471117343 2018-05-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1487801322 2015-08-31 Enhanced Recovery Project Violations Noted Inspect well for integrity and pressure. The injection line fitting were seeping. The identification has faded.
1568272996 2015-09-23 Enhanced Recovery Project No Violations The well head fittings have been replaced and are not leaking. The identification has not been updated. Compliance Notice of 8/31/2015 has not been completely fulfilled.
1588786360 2020-5-5 0:00:0 WR No Violations
1653326163 2017-04-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1682409842 2016-04-25 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The annulus shut off valve failed during inspection. Pressure bled off to about 100 psi. Plug was installed to prevent release of fluids. The operator was notified of the issue for repair.
1715882665 2012-09-11 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1753163738 2012-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1859074228 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1918617439 2010-04-06 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1924098789 2017-07-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1930732399 2007-01-31 Enhanced Recovery Project No Violations Pulled tension on 1 packer and tested well. No decline in pressure for 15 minutes. NOV in compliance.
1936349865 2008-12-12 Enhanced Recovery Project No Violations Pressured annulus up to 200 psi and 0 psi decline in 15 minutes.
1945272411 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1957776983 2009-10-07 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1970502881 2003-08-07 Enhanced Recovery Project No Violations
1985501138 2010-11-27 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1997250888 2006-12-15 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Packer failed. Equal pressure at 350psi.
2033642765 2014-03-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2043386651 2009-04-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2108777259 2013-08-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2146379179 2006-04-24 Enhanced Recovery Project No Violations Injection and annulus pressure test.
236759038 2016-7-11 0:00: ER No Violations
262829025 2007-10-12 0:00 ER No Violations 0.50
355333593 2019-7-24 0:00: ER No Violations
481762512 2017-1-9 0:00:0 ER No Violations
514951239 2008-12-11 0:00 ER No Violations 1.00
756016797 2007-4-3 0:00:0 ER No Violations 1.00
795597986 2013-5-22 0:00: ER No Violations
870297015 2016-11-7 0:00: ER No Violations
891080424 2018-10-2 0:00: ER No Violations
894782539 2020-1-23 0:00: ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0107567962 US-OH-101600 2006-03-15 Mechanical failure/contamination
0262829025 US-OH-122715 2007-10-12 Failure to conduct or pass mech. integrity test
0274745348 US-OH-122840 2006-03-15 Mechanical failure/contamination
0695217903 US-OH-127861 2007-03-30 Failure to conduct or pass mech. integrity test
1133972805 US-OH-103404 2005-12-07 Mechanical failure/contamination
1487801322 US-OH-113852 2015-10-07 Violation of injection tubing/fitting requirements
1487801322 US-OH-113853 2015-10-07 Insufficient/No identification
1997250888 US-OH-120267 2006-12-15 Failure to conduct or pass mech. integrity test

For data sources see[9]