X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-21970

Well Details

Well ID: 34-005-21970
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: H & F OIL CO
License Status: Active Injection
License Date: 1984-08-15
Spud Date: 1984-09-04
Spud Drilling Contractor: HILLER DRLG
Final Drill Date: 1984-09-04
Well Total Depth: 658.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-08-15 133 QUAKER STATE OIL REF CORP GeoDate 8/15/84
Enhanced Recovery 1984-08-15 Issued Date 8/15/84 Expired Date 2/11/85 Acres 0005300 Tool Type CT Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Completed 1984-09-04 CONVERT 8-18-84 INJECTION WELL
Original Spud 1984-09-04 CONVERT 8-18-84 INJECTION WELL
Reached Total Depth 1984-09-04 CONVERT 8-18-84 INJECTION WELL
First Injection 1984-10-18 CONVERT 8-18-84 INJECTION WELL
Completion Report Received 1984-12-07 CONVERT 8-18-84 INJECTION WELL
Construction Permit Expires 1985-02-11 CONVERT 8-18-84 INJECTION WELL
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 8/15/84
Annulus Pressure Monitoring Approved 1999-02-01 CONVERT 8-18-84 INJECTION WELL
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2009-02-04 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Last Compliance Report 2010-10-27 CONVERT 8-18-84 INJECTION WELL
Record Last Modified 2014-09-25 CONVERT 8-18-84 INJECTION WELL

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-10-05 0 0
0 0
2006-09-11 530 595 0
530 595 0
0 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 200 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP 0.00 71.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1108555528 2007-10-10 0:00 ER No Violations 0.50
-1123800846 2006-12-19 0:00 ER No Violations 1.00
-1241166182 2007-5-24 0:00: ER No Violations 1.00
-1268301813 2010-12-14 0:00 ER No Violations 0.50
-1556233587 2012-2-27 0:00: ER No Violations
-1667117485 2009-4-25 0:00: ER No Violations 0.50
-1725898076 2020-1-30 0:00: ER No Violations
-1758672437 2016-7-6 0:00:0 ER No Violations
-1785704763 2004-4-21 0:00: ER No Violations
-180307673 2007-1-31 0:00: ER No Violations 0.50
-1819291798 2012-4-24 0:00: AM No Violations
-1823247191 2018-8-14 0:00: ER No Violations
-2021451560 2011-10-18 0:00 ER No Violations
-304831881 2018-1-18 0:00: ER No Violations
-359292880 2016-11-1 0:00: ER No Violations
-572799425 2018-5-2 0:00:0 ER No Violations
-648729508 2019-4-22 0:00: ER No Violations
-747697495 2017-1-5 0:00:0 ER No Violations
0038554445 2011-07-11 Enhanced Recovery Project No Violations Inspect well. Pressure up well.
0180307673 2007-01-31 Enhanced Recovery Project No Violations Annulus mini-test is at 130 psi and injection pressure is at 360 psi. Last test, annulus reading was 0 psi. Test approved. 15 degrees, sun.
0304831881 2018-01-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0359292880 2016-11-01 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0454379705 2009-04-25 Enhanced Recovery Project No Violations Pressured up on annulus to 250 psi. After 15 minutes 0 psi drop in pressure. NOV in compliance.
0572799425 2018-05-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0626888451 2018-10-01 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head tubing is in very poor condition.
0708567633 2017-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0721669645 2017-04-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0747697495 2017-01-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1101132102 2004-11-17 Enhanced Recovery Project No Violations Injection pressure test.
1105388806 2017-10-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1108555528 2007-10-10 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1123800846 2006-12-19 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1140179882 2008-04-07 Enhanced Recovery Project No Violations Annulus and injection pressure test.
1144963264 2019-10-24 0:00 ER No Violations
1229608243 2008-12-18 Enhanced Recovery Project Violations Noted Pressure up to 200 psi on annulus and test for 15 minutes.
1235660381 2009-02-26 Enhanced Recovery Project No Violations Pressured up annulus to 300 psi and pressure fell 5 psi in 15 minutes. Tightened valve and pressure held for 15 minutes. NOV in compliance.
1241166182 2007-05-24 Enhanced Recovery Project No Violations Injection and annulus pressure test. Advised Len Rex to pressure annular side to 200 psi and report to inspector.5-24-2007 pressured up annular side to 240 psi and pressure declined to 220 psi. pressured up again to 240psi and it held for 15 minutes.
1254835041 2009-10-06 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1268301813 2010-12-14 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. ERP# 13,W-1, Pump up to 200 psi and test.
1270730684 2010-04-08 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1292908541 2006-08-22 Enhanced Recovery Project No Violations Injection and annulus pressure test. Sun, 75 degrees.
1296053036 2011-01-26 Enhanced Recovery Project No Violations Injection and annulus pressure test. Re-set packer. Pressured up annulus to 250 psi. 0 psi decline in 15 minutes.
1339197390 2012-06-04 Enhanced Recovery Project No Violations Inspect Well.
1348230242 2012-09-11 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1355163707 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1362577381 2013-03-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1369399584 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Injector line is leaking.
1378467250 2013-08-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1384957691 2013-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1395232077 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The annulus pressure could not be tested due to water in the box being frozen and the shutoff valve for the annulus is below the frozen water level.
1399922041 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1403386046 2020-8-5 0:00:0 ER No Violations
1408460188 2014-08-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1414602909 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1426864016 2015-03-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1432728688 2015-05-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1441210854 2015-08-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1447167125 2015-11-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head is in fair condition. Notified the operator the supply hose nipple is in poor condition.
1452523049 2016-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1511807574 2005-04-27 Enhanced Recovery Project No Violations Injection well test.
1517584123 2018-01-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1556233587 2012-02-27 Enhanced Recovery Project No Violations Inspect well. Broke in. shut in well.
1667117485 2009-04-25 Enhanced Recovery Project Violations Noted Injection and annulus pressure test.
1758672437 2016-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1785704763 2004-04-21 Enhanced Recovery Project No Violations Injection pressure test.
1819291798 2012-04-24 Administrative Inspection No Violations Contacted by operator, reset packer and well held pressure.
1823247191 2018-08-14 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1890046740 2016-04-25 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
194250228 2020-5-13 0:00: ER No Violations
1985541888 2006-01-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2003052216 2019-8-5 0:00:0 ER No Violations
2021451560 2011-10-18 Enhanced Recovery Project No Violations Inspect well. Pressure at zero. Pumped well up.
2100936309 2003-08-07 Enhanced Recovery Project No Violations CANNOT MEASURE INJECTION PRESSURE, NEED TO INSTALL 1/2 OR 1/4 VALVE FOR GAUGE
38554445 2011-7-11 0:00: ER No Violations
395852364 2019-1-9 0:00:0 ER No Violations
454379705 2009-4-25 0:00: ER No Violations 1.00
626888451 2018-10-1 0:00: ER No Violations
708567633 2017-7-17 0:00: ER No Violations
721669645 2017-4-20 0:00: ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1229608243 US-OH-106176 2008-12-18 Failure to conduct or pass mech. integrity test
1268301813 US-OH-107205 2010-12-14 Failure to conduct or pass mech. integrity test
1667117485 US-OH-116476 2009-04-25 Failure to conduct or pass mech. integrity test

For data sources see[9]

References