34-005-21276

Well Details

Well ID: 34-005-21276
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: SMALLEY (HASTINGS)
License Status: Plugged and Abandoned
License Date: 2017-06-22
Spud Date: 1956-02-09
Spud Drilling Contractor:
Final Drill Date: 1956-02-14
Well Total Depth: 805.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.170000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1956-02-09 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Completed 1956-02-14 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Reached Total Depth 1956-02-14 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
CO 1991-09-16 4076 PAULUS FRANCIS S GeoDate
CO 1996-03-27 133 QUAKER STATE OIL REF CORP
CO 1996-03-27 4959 R & B ENTERPRISES USA INC GeoDate
Change of Owner 2001-05-01 Operator changed from 4959, R & B ENTERPRISES USA INC to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2007-10-05 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
APP 2011-06-07 Proposed Formations:BEREA, Issued Date:6/7/2011, Expired Date:6/6/2013 12:00:00 PM, Drilling unit acres:155, Proposed Well Type:OG, Proposed Well Class:
APP 2017-06-22 Proposed Formations:BEREA, Issued Date:6/22/2017, Expired Date:6/22/2019 12:00:00 PM, Drilling unit acres:155, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2018-08-22 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Record Last Modified 2019-05-10 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.
Construction Permit Expires 2019-06-22 UPDATED LOCATION PER SURVEYOR COORDINATES 09/1/2017 ALE.

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 MILLER ROY/R A MILLER ENERGY L 0.00 67.00 365
2005 MILLER ROY/R A MILLER ENERGY L 0.00 7.00 365
2006 MILLER ROY/R A MILLER ENERGY L 0.00 0.00 365
2007 DEEP RESOURCES LLC 0.00 53.00 365
2008 DEEP RESOURCES LLC 0.00 168.00 365
2009 DEEP RESOURCES LLC 0.00 565.00 365
2010 DEEP RESOURCES LLC 0.00 0.00 0
2011 DEEP RESOURCES LLC 0.00 0.00 0
2012 DEEP RESOURCES LLC 0.00 0.00 0
2014 DEEP RESOURCES LLC 0.00 0.00 0
2016 DEEP RESOURCES LLC 0.00 0.00 0
2017 DEEP RESOURCES LLC 0.00 0.00 0
2018 DEEP RESOURCES LLC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 MILLER ROY/R A MILLER ENERGY L Brine 0 365
2005 MILLER ROY/R A MILLER ENERGY L Brine 0 365
2006 MILLER ROY/R A MILLER ENERGY L Brine 0 365
2007 DEEP RESOURCES LLC Brine 0 365
2008 DEEP RESOURCES LLC Brine 0 365
2009 DEEP RESOURCES LLC Brine 0 365
2010 DEEP RESOURCES LLC Brine 0 0
2011 DEEP RESOURCES LLC Brine 0 0
2012 DEEP RESOURCES LLC Brine 0 0
2014 DEEP RESOURCES LLC Brine 0 0
2016 DEEP RESOURCES LLC Brine 0 0
2017 DEEP RESOURCES LLC Brine 0 0
2018 DEEP RESOURCES LLC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1056768077 2011-3-4 0:00:0 PW No Violations 2.00
-708396030 2018-8-27 0:00: PB No Violations
-78862351 2018-8-22 0:00: PB No Violations
0016776134 2018-08-20 Plug / Plug Back No Violations The operator requested inspection to witness plugging operations at the well. Cement was tagged in the tubing at 200 feet down. Cement was tagged outside the tubing at 120 feet. The annulus between the 1.5 inch tubing and 4.5 inch casing was filled solid with cement. The tubing was filled up to the top several times with cement by pumping down 1 inch plastic line installed in the tubing. Cement continued to fall down hole after pumping. The operator shut down for lunch and returned and attempted top up of the tubing again. Cement dropped following pumping. The operator is going to let cement set up overnight and attempt top up again in the morning.
0078862351 2018-08-22 Plug / Plug Back No Violations The operator is cutting off casings at 3 foot depth. No leakage observed from the well. Cement is at surface in the 1.5 inch tubing and 4.5 inch casing. The pit has been pumped down. The operator is going to remove the liner and restore the location. 38 bags of type 1 cement were pumped in the well in addition to 1.5 to 2 yards of 9 sack grout placed in the well by Moritz Materials.
0708396030 2018-08-27 Plug / Plug Back No Violations The well has been cut off 3 feet below grade. The operator has prepared a cover plate for the well. The pit liner needs to be pumped out and removed from the pit and the location needs to be finish graded and vegetated.
0930274967 2015-10-30 Production Wells No Violations I spoke with Deep Resources personnel regarding plugging or repairing the well to bring it into compliance. Tom Benko, ODNR was on site. The service rig is currently on an injection well and will be moving to another injection well following servicing the one they are currently on. Inspector Benko has issued compliance notices on several injection wells for leakage and the operator is addressing those at higher priority than production wells. They are planning to plug the well but they dont have a timetable for doing so at present. Randy Matheny of Deep Resources was on vacation. John and Ethan of Deep Resources were the points of contact.
0962313787 2015-04-10 Production Wells Violations Noted The well is shut in with a swage on the production casing. Gas was bubbling up through fluid in the surface production annulus. The well is idle and unidentified. Harold Moravy stated in a previous report that Len at Deep Resources was planning to plug the well. Len is no longer with the company. The well needs to be plugged and the location restored by 10/23/15.
1056768077 2011-03-04 Production Wells No Violations Requested by Len Rex to research history of well for accurate well records. Inspected GPS location and found a Berea well . It is idle and equipped with 7 and 3 casing with a swedge in 3 casing. No production equipment on well or tank battery. Production records indicate well produced 589 barrels of oil in 2009. This well has not produced for years. Advised Len Rex to plug or produce well. Cloudy, 35 degrees.
1468503734 2016-07-14 Production Wells No Violations The operator installed a pump jack, rods and tubing. There is a 50 barrel tank at the well. After pumping the well, the operator has decided to continue with plugging it.
1534168042 2018-08-10 Plug / Plug Back No Violations The rig is unable to move the tubing today. The well would not circulate through the tubing either. The operator contacted wireline companies to schedule cutting the tubing off to finish plugging the well. Wireline service is scheduled for Tuesday 8/14.
1534275067 2018-08-14 Plug / Plug Back No Violations JET Wireline made attempts to cut tubing and the rig attempted to pull it from the well. Tubing was shot at 400 feet and was still in cement. Cement was tagged in the 4.5 inch-tubing annulus at 200 feet. Tubing did not pull free after cutting at 200 feet. The rig crew unscrewed tubing and 3 joints were recovered. The tubing was re-installed. The rig crew ran 500 feet of 1 inch plastic pipe inside the 1.5 inch tubing. The operator is going to fill tubing and the annulus with cement to finish plugging the well.
1534771961 2018-08-17 Plug / Plug Back No Violations The operator requested inspection to witness well plugging operations. 20 sacks of type 1 cement was pumped in the well through 1 inch plastic tubing inside the 1.5 inch tubing. Circulation returned up the 1.5 inch tubing.
16776134 2018-8-20 0:00: PB No Violations
1932613736 2018-08-09 Plug / Plug Back No Violations The operator requested inspection to witness plugging the well. Tubing was ran in to 795 feet. After starting grout down the well, the rig operator attempted to raise tubing and became hung up. About 1.5 - 2 yards of cement was placed in the well. Tubing moved and rotated but the rig was unable to free it from the well. The well was circulated with fresh water and then stopped circulating. The operator is going to make additional attempts to free the tubing tomorrow.
930274967 2015-10-30 0:00 PW No Violations 2.00
962313787 2015-4-10 0:00: PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0962313787 US-OH-131013 2015-05-04 Well insufficiently equipped to prevent escape of oil and gas
0962313787 US-OH-131014 2015-05-04 Failure to legibly identify well
0962313787 US-OH-131015 2015-05-04 Well shall be plugged

For data sources see[7]