X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-21121

Well Details

Well ID: 34-005-21121
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Mifflin Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: MARKLEY EARL F
License Status: Storage Well
License Date:
Spud Date: 1954-11-05
Spud Drilling Contractor:
Final Drill Date: 1954-12-13
Well Total Depth: 2665.00 ft
Configuration: Vertical
Latitude: 40.800000
Longitude: -82.360000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1954-11-05
Completed 1954-12-13
Reached Total Depth 1954-12-13
Record Last Modified 2013-05-23

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-08-04 H2O 0 11274 Gal 26900 Universal Well Services Inc. The job was a nitrogen assisted fracture stimulation. 43,750 cubic ft of nitrogen gas was used. The liquid was a cross linked fresh water gel. This was a refracture and cleanout of the well and there was no observed break of the formation. Injection test pressure was 1748 psi at 18 barrels per minute. 250 gallons of hydrochloric acid was pumped ahead of the sand.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1275482662 2020-4-22 0:00: SO No Violations
-132336051 2014-8-4 0:00:0 SO No Violations 5.00
-1820956778 2016-5-25 0:00: SO No Violations 0.50
-1856753647 2015-7-24 0:00: SO No Violations 0.50
-972431943 2019-3-7 0:00:0 SO No Violations
0132336051 2014-08-04 Storage Well No Violations The operator is conducting a fracture stimulation on the well. See the report for details.
0477464142 2017-04-24 Storage Well No Violations ID is posted and the location is maintained. The gate valve is open; the annulus is shut in. There is a house gas meter at the well. The well is not equipped with a separator.
0972431943 2019-03-07 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #9422 on 03/07/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and 1-meter with 2-regulators. Well identification is clearly displayed. The well is located ~120 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection.
1172848227 2013-11-06 Storage Well No Violations The well and location are in compliance.
1524162904 2018-04-19 Storage Well No Violations ID is posted and the location is maintained. The annulus is shut in. There is a house gas connection at the pipeline tie in.
1820956778 2016-05-25 Storage Well No Violations ID is posted and the location is maintained. There is no separator at the well. The annulus is shut in.
1856753647 2015-07-24 Storage Well No Violations ID is posted. The location is maintained. Backside valves are closed and have pipe plugs in them.
477464142 2017-4-24 0:00: SO No Violations 0.50

For data sources see[4]

References