If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-20406 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.81,"lon":-80.75,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Center Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: ARMSTRONG CLYDE | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1954-08-05 | |
Spud Drilling Contractor: | |
Final Drill Date: 1954-09-08 | |
Well Total Depth: 807.00 ft | |
Configuration: Vertical | |
Latitude: 40.810000 | |
Longitude: -80.750000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1954-08-05 | |
Completed | 1954-09-08 | |
Reached Total Depth | 1954-09-08 | |
Change of Owner | 2011-08-05 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
Record Last Modified | 2011-08-17 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | R.P. 24 HRS. |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-15688887 | 2019-4-11 0:00: | SO | No Violations | |
-1615404015 | 2015-9-24 0:00: | SO | No Violations | |
-629771990 | 2013-5-8 0:00:0 | SO | No Violations | |
-689191723 | 2016-5-3 0:00:0 | SO | No Violations | |
0015688887 | 2019-04-11 | Storage Well | No Violations | I was on location to check this storage well with Columbia Gas and US Department of Transportation personnel during a PHMSA (Pipeline and Hazardous Materials Safety Administration) audit of the Brinker field. The well was equipped with a master valve and a side wing valve. The annular pressure was gauged and read 156 psi The tubing pressure was 157 psi. Proper identification was posted. The access road was stable. I observed no violations at the time of inspection. |
0629771990 | 2013-05-08 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well # 4172 today. The well is located in Section 36, Salem Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found. |
0689191723 | 2016-05-03 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
1615404015 | 2015-09-24 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
1775597396 | 2014-11-06 | Storage Well | No Violations | I inspected Columbia Gas Transmission gas well #4172. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found. |
1842386510 | 2017-03-02 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check on well # 2-0406. Access to the well over a crushed gravel road that was in good repair. The well location was stable with well established vegetation. Correct and legible identification was present at the well. Well head annular side ports contained closed and plugged valves. The top of the well head was equipped with a master gate valve and side gate valve. A 4 line was plumbed out of the side gate valve into a vertical drip. A 4 line was plumbed out of the drip to the main line. Test valves were closed and plugged. No audible or visual leaks were detected. No violations were detected during this inspection. |
1984557940 | 2018-02-26 | Storage Well | No Violations | The purpose of my inspection was to conduct a status check on well #20406. Access to the well was stable and drivable. Correct identification was posted at the well. The surface casing was plumbed above grade. Annular valves were closed to atmosphere. The production casing was equipped with a master gate valve and wing valve. A 4.5 line connected the wing valve to a vertical drip. No leaks were observed. No violations were observed during this inspection. |
649163803 | 2020-4-6 0:00:0 | SO | No Violations | 1.00 |
For data sources see[4]