34-013-21175

Well Details

Well ID: 34-013-21175
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Goshen Township
Operator Name: RICE DRILLING D LLC
Well Pad ID: US-OH-001201
Farm/Lease Name: BOUNTY HUNTER
License Status: Producing
License Date: 2017-03-20
Spud Date: 2017-10-23
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2018-01-27
Well Total Depth: 18338.00 ft
Configuration: Horizontal
Latitude: 40.020000
Longitude: -81.030000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-02-08 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:2/8/2017, Expired Date:2/8/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2017-03-20 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:3/20/2017, Expired Date:3/20/2019 12:00:00 PM, Drilling unit acres:599.0951, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2018-01-27
Correction to Well 2018-03-29 UPDATE TARGET/TAKE PER AS-DRILLED PLAT- ALE
Completion Report Received 2018-09-06
Record Last Modified 2018-09-12
Construction Permit Expires 2019-03-20

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-09-11 9560 9741 0
2018-09-11 18177 18225 0
18177 18225 0
9560 9741 0
9560 9741 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 05/07/2018 06/09/2018 9130 18,852,800.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-150 FTS International Acid Corrosion Inhibitor Listed Below
Quartz 14808-60-7 4 0.00000284 5.222
Aromatic aldehyde Proprietary 10 0.00002337 42.96
Trade Secret Proprietary 5 0.00000065 1.189
Trade Secret Proprietary 1 0.00000013 0.238
Trade Secret Proprietary 40 0.00000518 9.513
Ethylene Glycol 107-21-1 30 0.00007011 128.88
Isotridecanol, ethoxylated 9043-30-5 2 0.00000142 2.611
Guar gum 9000-30-0 50 0.00003551 65.279
Guar gum 9000-30-0 50 0.00003551 65.279
Hydrochloric Acid 7647-01-0 15 0.020892 38403.7
Trade Secret Proprietary 15 0.00000194 3.567
Ammonium persulfate 7727-54-0 95 0.00000155 2.85
Isopropanol 67-63-0 30 0.00007011 128.88
Sodium hydroxide 1310-73-2 5 0.000788104 1448.69
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0254958 46866.3
Trade Secret Proprietary 5 0.00000065 1.189
Ethylene Glycol 107-21-1 10 0.00234063 4302.53
Ammonium persulfate 7727-54-0 95 0.00000155 2.85
Raffinates, Sorption Process 64741-85-1 55 0.00003906 71.807
Lubricating oils (petroleum), C20-50,

hydrotreated neutral oil-based

72623-87-1 45 0.00000582 10.702
Trade Secret Proprietary 40 0.00000518 9.513
Quartz 14808-60-7 4 0.00000284 5.222
Dimethylformamide 68-12-2 10 0.00002337 42.96
Quaternary ammonium compound Proprietary 10 0.00002337 42.96
Sodium hydroxide 1310-73-2 5 0.000788104 1448.69
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0254958 46866.3
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.0042493 7811.05
Sodium hypochlorite 7681-52-9 16 0.00252193 4635.81
Trade Secret Proprietary 15 0.00000194 3.567
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.0042493 7811.05
Lubricating oils (petroleum), C20-50,

hydrotreated neutral oil-based

72623-87-1 45 0.00000582 10.702
Silica Substrate 14808-60-7 100 14.1486 26,008,000.0
Trade Secret Proprietary 1 0.00000013 0.238
Raffinates, Sorption Process 64741-85-1 55 0.00003906 71.807
Isotridecanol, ethoxylated 9043-30-5 2 0.00000142 2.611
Organic amine resin salt Proprietary 30 0.00007011 128.88
Sodium hypochlorite 7681-52-9 16 0.00252193 4635.81
APB-1 FTS International Gel breaker Listed Below
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 85.5876 157,327,000.0
Hydrochloric Acid FTS International Acidizing Listed Below
CS-500-SI FTS International Scale inhibitor Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 89.7 0.0141386 25989.5
Water 7732-18-5 15 0.00000194 3.567
FRW-1450 FTS International Friction reducer Listed Below
HVG-1 4.0 FTS International Water gelling agent Listed Below
Sand (Proppant) FTS International Proppant Listed Below
Silver 7500 P.O.P. Silverback Chemical Polymer Water 7732-18-5 89.7 0.0141386 25989.5
Water 7732-18-5 15 0.00000194 3.567
Sodium Hypochlorite Dirk Thomas Solutions Biocide Listed Below

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2018-05-07 H2O 15 6267 Bbl 199585 Frac Tech Services STAGE 1 OF 44
2018-06-09 H2O 15 10207 Bbl 600412 Frac Tech Services STAGE 44 OF 44 SEE IMAGES FOR STAGES 2-43

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 RICE DRILLING D LLC 1964462 0 136
2019 RICE DRILLING D LLC 1387188 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 RICE DRILLING D LLC Brine 32286 136
2019 RICE DRILLING D LLC Brine 14751 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1541659210 2018-7-24 0:00: CT No Violations 0.50
-1922062354 2018-8-8 0:00:0 CT No Violations 0.30
-277787 2020-7-9 0:00:0 PL No Violations 0.30
-3287320 2020-2-21 0:00: PW No Violations 0.20
-480472094 2018-1-18 0:00: DD No Violations 1.00
-827209561 2018-8-8 0:00:0 CT No Violations 0.20
0105465262 2018-07-24 Completion Testing No Violations Status check inspection accompanied by ODNR Inspector Ryan Armstrong found the well drilling and stimulation process complete. The well head master valves used during the completion process are still in place with a manual and hydraulic master valve present. A coil tubing unit owned by Cudd Services is scheduled to move onto the well site and rig up on the hole in the next 24 hours. There is a total of 43 completion plugs to drill out. Annular pressure monitoring is in place with zero pressure on the 13.375 well head section (between the 9.625 and 13.375 and zero pressure on the 9.625 well head section between the 5.5 and 9.625 casing strings. The well pad is equipped with polymer containment on the surface.
0480472094 2018-01-18 Drill / Deepen / Reopen No Violations On the day of my inspection I found Patterson 296 had just skidded this morning. The 9.625 inch diameter casing was previously set at 8313 feet. They will be ging back in the hole with 8.75 inch diameter bit tonight. Containment is functioning, one section of berm approxzimately 10 feet long was repaired while I was onsite. This is the containment below the rig and mats not a pad berm.
0531036371 2018-06-21 Completion Testing No Violations The said well drilling and stimulation process is complete, the well was stimulated in 44 stages. There is 3 wells on the pad that were recently drilled with 2 stimulated and the 3rd and final well now being stimulated. The company is monitoring all annular pressures.
0827209561 2018-08-08 Completion Testing No Violations On the day of my inspection I witnessed that the well was setting static with annular pressure monitoring in place. After speaking with company man Matt Bradford, he informed me that the all 43 isolation plugs on the well had been drilled out and the well was waiting to commence flowback operations. Mountain State Pressure Systems was currently on location drilling out isolation plugs on 34013211820000. There were 4 producing wells on location that were covered with steel cages.
105465262 2018-7-24 0:00: CT No Violations 0.50
1171020607 2020-6-24 0:00: PW No Violations 0.40
1508869525 2017-10-24 Casing String Witnessed No Violations On site inspection to witness the conductor casing cement job accompanied by ODNR Inspector Andrew Corder. On this day it was observed that Express Energys top hole rig has drilled a 36 diameter conductor borehole to a measured depth of 100 and inserted 100 of 30 diameter .375 wall weld connection casing. Express Energys Cement Service cemented the casing using a 57 barrel absolute volume cement mix consisting of 275 sacks of class A cement with the cement weight verified at 15.6 pound per gallon by weight of scale and the cement displaced with 75 barrels of fresh water. Cement returns were witnessed to surface inside the cellar.
1508943956 2017-10-24 Casing String Witnessed No Violations On location with Inspector Bill Stolarik. Express energy had reached the total depth of the 36-inch diameter open hole section of the well bore. The 32-
1516720273 2018-01-22 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed Patterson 296 driling an 8.5 inch diameter lateral hole section at a depth of 13610 feet. Containment is functioning and repaired berm viewed in last inspection is still functioning. Small flare burning occasionally on location.
1527171247 2018-05-24 Completion Testing No Violations Status check follow up inspection to an unreported incident that occurred on 05/11/2018 at 18:01 pm involving the said well. My investigation found that on 5/11/18 the company was stimulating stage 9 out of a proposed 44 stages to stimulate and was 60% complete with the stage and pumping at a rate of 100.5 barrels per minute with a treating pressure of 10,300 pounds per square inch when a spacer spool in the 7.125 completion well head assembly failed. The Silver Creek companys completion stack was situated on top of the B section of the GE (General Electric) well head assembly and the spool was situated between the lower manually operated master valve and the hydraulic master valve. The weld on the spool failed allowing the completion assembly to separate and fall off the well head. A worker was able to access the manually controlled lower master valve and control the well flow. The company man on site reported a undetermined amount of well bore related product was dispersed onto the polymer containment and a total estimated 2 barrels of fluid lost off the polymer containment and onto the well pad. The company man on site identified as Walt Arnold indicated the product on containment was recovered and the liner removed and replaced and the area off containment but on the well pad was remediated by removing the affected material and recovering any fluid with a vacuum truck. There was a small amount of standing fluid in a depression on the well pad that was titrate tested for chlorides with a low level Quantab strip test and found to exceed the low level strip test reading of 637 parts per million, I also titrate tested the same area with a high level Quantab strip test and found 751 parts per million chlorides. Directions were given to the company man on site Walt Arnold to continue to recover any surface water on the pad from this area. All perimeter drain valves were reported as closed. The current well pad operations are, the Bounty Hunter H-1 & H-3 are being si
1541659210 2018-07-24 Completion Testing No Violations On the day of my inspection accompanied by ODNR inspector Bill Stolarik I witnessed that there was a completion stack on the well head with a manual master valve and hydraulic master valve present. Annular pressure monitoring was in place and the 13.375-inch diameter casing had 0 pounds per square inch and the 9.625-inch diameter casing had 0 pounds per square inch, the 18.625-inch diameter casing was also being monitored and was at 0 pounds per square inch. After speaking with EQT company man he informed me that they would be moving a CUDD coil tubing unit on the well on 7/25/2018 and would proceed in drilling the isolation plugs.
1922062354 2018-08-08 Completion Testing No Violations On site inspection accompanied by ODNR Inspector Ryan Armstrong. Currently there are 4 producing wells on the pad and 3 new wells that the company has service crews on location and completing. The said well is equipped with a lower A section and upper B section with a completion stack present owned by Cameron well company, the well will initially produce through this stack. The production equipment includes 4 gas processing units and 2 glycol heaters. Upon entering the location on the left side of the well pad is the production fluid facility consisting of 6 steel construction 400 barrel fluid capacity production tanks situated inside a polymer lined steel containment dike area. The well has had the completion plugs drilled out with a total of 46 plugs set during the completion process. No tubing will be set in the well only a tubing hanger. The company is monitoring annular pressure.
2042089368 2019-01-24 Production Wells No Violations On site inspection found the said well now in production and selling off the 5.5 diameter production casing through (2) primary master valves. The casing pressure is being monitored off a electronic transducer. No annular pressure monitoring is in place. 2 Crew Men from EQT are on site replacing the emergency shut down master valve hydraulic fluid. 3 wells were recently drilled and completed and 4 pre existing wells. Production equipment consists of 5 gas processing units along with a (6) steel 400 barrel capacity steel tanks situated inside a polymer lined steel containment dike area. The well pad perimeter is protected by an earthen berm however one section was removed near the mid stream equipment and not put back. At the rear of the pad is the mid stream operation operated by EQT. I contacted ODNR Engineer Technician Anthony Carson and he will address the issue with the perimeter berm. We have addressed this issue one before and it was addressed. The Preliminary Restoration is due however recent disturbance around the well pad caused by mid stream installation shall delay the restoration until proper vegetation is established. The well pad and lease road surface is stone and in good repair.
531036371 2018-6-21 0:00: CT No Violations 0.20
667802961 2020-9-25 0:00: PW No Violations 0.20

For data sources see[10]