{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.731899097,"lon":-81.14446886,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Perry Township | |
Operator Name: FUTURE PRODUCTION INC | |
Well Pad ID: | |
Farm/Lease Name: SLOWEY/RUSSELL | |
License Status: Producing | |
License Date: 1984-09-11 | |
Spud Date: 1984-10-24 | |
Spud Drilling Contractor: MARTIN DRILLING | |
Final Drill Date: 1984-10-29 | |
Well Total Depth: 3253 ft | |
Configuration: Vertical | |
Latitude: 41.731899097 | |
Longitude: -81.14446886 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1984-09-11 | Issued Date 9/11/84 Expired Date 3/10/85 Acres 0024800 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03253 Proposed Drill Depth 03253 |
Original Spud | 1984-10-24 | |
Completed | 1984-10-29 | |
Reached Total Depth | 1984-10-29 | |
CO | 1984-11-15 | 3442 CUTTER EXPLORATION INC GeoDate 9/11/84 |
Construction Permit Expires | 1985-03-10 | |
Completion Report Received | 1986-06-12 | |
CO | 1993-04-20 | 3370 FUTURE PRODUCTION INC GeoDate 9/11/84 |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3061 | 3139 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 250 Mscf | 0 | |||
H2O | 0 | 1730 | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | CUTTER OIL COMPANY | 19189 | 394 | 184 |
1986 | CUTTER OIL COMPANY | 20896 | 289 | 365 |
1987 | CUTTER OIL COMPANY | 5676 | 193 | 365 |
1988 | CUTTER OIL COMPANY | 3053 | 98 | 365 |
1989 | CUTTER EXPLORATION INC | 2255 | 77 | 365 |
1990 | CUTTER EXPLORATION INC | 1512 | 100 | 365 |
1991 | CUTTER EXPLORATION INC | 1282 | 100 | 365 |
1992 | CUTTER EXPLORATION INC | 1043 | 83 | 365 |
2001 | FUTURE PRODUCTION INC | 36 | 0 | 31 |
2002 | FUTURE PRODUCTION INC | 58 | 0 | 96 |
2003 | FUTURE PRODUCTION INC | 66 | 0 | 103 |
2004 | FUTURE PRODUCTION INC | 56 | 0 | 365 |
2006 | FUTURE PRODUCTION INC | 52 | 0 | 365 |
2007 | FUTURE PRODUCTION INC | 68 | 0 | 365 |
2008 | FUTURE PRODUCTION INC | 62 | 0 | 365 |
2009 | FUTURE PRODUCTION INC | 68 | 0 | 364 |
2011 | FUTURE PRODUCTION INC | 89 | 0 | 365 |
2012 | FUTURE PRODUCTION INC | 86 | 0 | 366 |
2013 | FUTURE PRODUCTION INC | 11 | 3 | 364 |
2014 | FUTURE PRODUCTION INC | 12 | 0 | 364 |
2015 | FUTURE PRODUCTION INC | 0 | 0 | 364 |
2016 | FUTURE PRODUCTION INC | 0 | 0 | 364 |
2017 | FUTURE PRODUCTION INC | 0 | 0 | 364 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | CUTTER OIL COMPANY | Brine | 1848 | 184 |
1986 | CUTTER OIL COMPANY | Brine | 1500 | 365 |
1987 | CUTTER OIL COMPANY | Brine | 570 | 365 |
1988 | CUTTER OIL COMPANY | Brine | 450 | 365 |
1989 | CUTTER EXPLORATION INC | Brine | 375 | 365 |
1990 | CUTTER EXPLORATION INC | Brine | 200 | 365 |
1991 | CUTTER EXPLORATION INC | Brine | 415 | 365 |
1992 | CUTTER EXPLORATION INC | Brine | 240 | 365 |
2001 | FUTURE PRODUCTION INC | Brine | 0 | 31 |
2002 | FUTURE PRODUCTION INC | Brine | 0 | 96 |
2003 | FUTURE PRODUCTION INC | Brine | 0 | 103 |
2004 | FUTURE PRODUCTION INC | Brine | 0 | 365 |
2006 | FUTURE PRODUCTION INC | Brine | 0 | 365 |
2007 | FUTURE PRODUCTION INC | Brine | 0 | 365 |
2008 | FUTURE PRODUCTION INC | Brine | 0 | 365 |
2009 | FUTURE PRODUCTION INC | Brine | 0 | 364 |
2011 | FUTURE PRODUCTION INC | Brine | 0 | 365 |
2012 | FUTURE PRODUCTION INC | Brine | 0 | 366 |
2013 | FUTURE PRODUCTION INC | Brine | 0 | 364 |
2014 | FUTURE PRODUCTION INC | Brine | 0 | 364 |
2015 | FUTURE PRODUCTION INC | Brine | 0 | 364 |
2016 | FUTURE PRODUCTION INC | Brine | 0 | 364 |
2017 | FUTURE PRODUCTION INC | Brine | 0 | 364 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL14298 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0066121655 | 2015-05-27 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued Compliance Notice. The well is comprised of a wellhead with mechanical plunger lift system in a small, chain-link enclosure. The interior of the enclosure is overgrown with dense vegetation. The tank battery is comprised of one 210-barrel steel production tank and vertical separator unit in a chain-link enclosure. The interior of this enclosure is also overgrown with dense vegetation., There is no identifying signage anywhere on this unit. According to discussions with Future Productions, changes made by Dominion/EOG have rendered it no longer possible to connect to the local sales distribution system. Further, discussions with the landowner indicate that no gas is being provided for domestic use. There has been no attempts by the well owner to address the issue of non-compliance. Im recommending a Chiefs Order be issued for enforcement. |
0069848581 | 2018-06-28 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to Compliance Notice issued on 11/14/2014 for failure to produce the well. As part of the Compliance Notice, Future Productions, Inc. (Owner) was directed to plug and abandon in accordance with Ohio Revised Code (ORC) 1509.12B. The owner was given a compliance date of 6 months from the date of the issuance of the Compliance Notice. At the time of this inspection, I observed the well to be idle and in a state of disrepair, and the stipulation of the Compliance Notice to plug and abandon the well had not been complied with. |
0285757548 | 2015-08-19 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to a previously-issued Compliance Notice for non-production. At the time of this inspection, conditions at the wellhead and battery are unchanged. The well remains in non-production. Discussions with the well owner have not been productive. There has not been any progress made towards returning the well to productive status. I will refer the matter for enforcement through the issuance of a Chiefs Order. |
0356395024 | 2018-05-01 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to Compliance Notice issued on 11/14/2014 for failure to produce the well. As part of the Compliance Notice, Future Productions, Inc. (Owner) was directed to plug and abandon in accordance with Ohio Revised Code (ORC) 1509.12B. The owner was given a compliance date of 6 months from the date of the issuance of the Compliance Notice. At the time of this inspection, I, along with Northeast Regional Supervisor Tom Hill, met with property owner Robert Slowey, at the location. Mr. Slowey indicated that Future Productions has not maintained the well, and had not been responsive to his attempts to contact them. He further indicated that he wished to have the well plugged and abandoned. I observed the well to be idle and in a state of disrepair, and the stipulation of the Compliance Notice to plug and abandon the well had not been complied with. I contacted Brett Huntsman on 05/01/2018 who had not responded to a phone message, at the time of this report filing. |
0810507861 | 2018-08-30 | UrbanProduction Wells | No Violations | I inspected this well location as a follow-up to Chiefs Order #2014-459. At the time of this inspection, I noted the following: the well and associated production elements consisting of a 210-barrel steel stock tank, mechanical separator, and concrete brine vault remained in a similar condition of disuse and disrepair. There has been no apparent attempts by the owner to obtain a permit to plug the well. There remains no active insurance. |
0912484978 | 2017-06-05 | Production Wells | No Violations | I inspected this well as a follow-up to Compliance Notice issued on 11/14/2014 for failure to produce the well. As part of the Compliance Notice, Future Productions, Inc. (Owner) was directed to plug and abandon in accordance with Ohio Revised Code (ORC) 1509.12B. The owner was given a compliance date of 6 months from the date of the issuance of the Compliance Notice. At the time of this inspection, the Owner had failed to comply with the Compliance Notice. I observed the well to be idle and in a state of disrepair. I contacted Brett Huntsman on 06/05/2017 and advised that the Owner had not complied with the directive . We agreed the Owner must establish a course of action within two weeks, or by 06/16/2017. |
1120724390 | 2004-02-09 | Production Wells | No Violations | inspection for tank location . 210BBL, buried salt ,seoerator. |
1122935482 | 2016-06-24 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a compliance notice issued on 11/14/2014. At the time of this inspection, I observed the following: one wellhead with plunger lift system located in a small chain-link enclosure. The interior of the enclosure was overgrown with vegetation. The flow-line connection was closed at the wellhead. There is a domestic supply connection at the wellhead which was open. The battery was comprised of one 210-barrel steel tank, and a separator. Both the interior of the battery and surrounding area is overgrown extensively with vegetation. No production has been reported since 2012. There was a domestic supply connection at the house located at 3950 River Road. The domestic supply was closed at the house. The well owner has not responded with a plan to return the well to production. |
1156409502 | 2014-11-05 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The wellhead plunger lift and battery are located on within a farmstead. The wellhead is located in a small chain-link enclosure. The interior of the enclosure is overgrown with vegetation obscuring much of the well from visual inspection. The battery is comprised of 1 210-barrel steel tank, and a separator. Both the interior of the battery and surrounding area is overgrown extensively with vegetation. No production was reported for 2013. The landowner has reported that there is no receipt of domestic gas from the well. Future Productions has reported that the infracture to sell commercial gas has been cut off. As such, the well owner must plug and abandon the well with 180 days or be subject to additional enforcement action. |
1309712424 | 2016-12-06 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previously-issued compliance notice. At the time of the issuance of the compliance notice, it was noted that there had been no reported production since 2012 and subsequent discussions with the well owner indicated that sales line connection had been truncated and could not be re-connected, rendering commercial production not possible. Further, the landowner has not been receiving domestic gas. Subsequent discussions with the well owner have indicated that the well has become uneconomical to commercially produce. At the time of this inspection, the fittings and connections at the wellhead were closed. The interior of the wellhead enclosure was overgrown with vegetation. Conditions at the tank battery had not changed. Elements consist of one 210-barrel steel production tank, an in-ground, cement brine tank, and separator unit in chain-link enclosure. The interior of the tank battery was overgrown with vegetation. There was no readable identifying signage. There was no evidence that on-going maintenance had been occurring. |
1485292747 | 2017-08-07 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to Compliance Notice issued on 11/14/2014 for failure to produce the well. As part of the Compliance Notice, Future Productions, Inc. (Owner) was directed to plug and abandon in accordance with Ohio Revised Code (ORC) 1509.12B. The owner was given a compliance date of 6 months from the date of the issuance of the Compliance Notice. At the time of this inspection, the Owner had failed to comply with the Compliance Notice. I observed the well to be idle and in a state of disrepair. I contacted Brett Huntsman on 06/05/2017 and advised that the Owner had not complied with the directive . We agreed the Owner must establish a course of action within two weeks, or by 06/16/2017. At the time of this inspection, Future Productions had made no progress or attempts to remedy the deficiency. |
1554742753 | 2019-04-08 | UrbanProduction Wells | No Violations | I conducted an order follow-up inspection for Chiefs Order (#2014-459) which issued a legal hold on production as of 10/15/2014 due to lack of current liability insurance. At the time of this inspection, the well was not in production and all valves on the well and flow lines were shut in. Tank battery location had a 210 BBL tank, concrete brine vault and mechanical separator. Valves at the separator were also closed. There is a current open compliance notice to plug this well dated 11/14/2014. The required plugging for this well was 5/15/2015. At the time of this inspection, the well was not in production and has not been plugged. |
1917692468 | 2019-02-01 | UrbanProduction Wells | No Violations | I conducted an order follow-up inspection for Chiefs Order (#2014-459) which issued a legal hold on production as of 10/17/2014 due to lack of current liability insurance. At the time of this inspection, the well was not in production and all valves on the well and flow lines were shut in. Tank battery location had a 210 BBL tank, concrete brine vault and mechanical separator. Valves at the separator were also closed. |
1939280348 | 2017-07-13 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to a Chiefs Order (#2014-459) which issued a legal hold on production as of 10/17/2014 due to lack of current liability insurance. At the time of this inspection, the well was shut in with no active connections. The owner has reported previously that the sales line connection has been disconnected. There is a domestic house connection at the house on the parcel, but the gate valve was closed. |
For data sources see[9]