X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-133-22762

Well Details

Well ID: 34-133-22762
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Freedom Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: SOUTH SLAGLE UNIT
License Status: Producing
License Date: 1981-11-16
Spud Date: 1981-11-27
Spud Drilling Contractor:
Final Drill Date: 1981-12-02
Well Total Depth: 4585 ft
Configuration: Vertical
Latitude: 41.219932257
Longitude: -81.11692766

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-11-16 28 CGAS EXPLORATION,INC GeoDate 11/16/81
Original Spud 1981-11-27
Completed 1981-12-02
Reached Total Depth 1981-12-02
Construction Permit Expires 1982-11-16
Change of Owner 2007-04-27 Operator changed from 28, CGAS EXPLORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4365 4420 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 70000 Gal 50000
N2 0 160 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 POMINEX INC 1787 1766 0
1985 POMINEX INC 1610 1487 365
1986 POMINEX INC 1431 1217 365
1987 POMINEX INC 465 1180 365
1988 POMINEX INC 1574 1081 365
1989 CGAS EXPLORATION 1360 891 365
2000 CGAS EXPLORATION 916 526 365
2001 CGAS EXPLORATION 875 537 365
2002 CGAS EXPLORATION 478 461 365
2003 CGAS EXPLORATION 601 436 365
2006 CGAS EXPLORATION 1111 576 365
2007 ENERVEST OPERATING LLC 353 311 365
2008 ENERVEST OPERATING LLC 412 497 365
2009 ENERVEST OPERATING LLC 494 369 365
2010 ENERVEST OPERATING LLC 707 402 365
2011 ENERVEST OPERATING LLC 574 367 0
2012 ENERVEST OPERATING LLC 718 447 366
2013 ENERVEST OPERATING LLC 695 310 365
2014 ENERVEST OPERATING LLC 636 356 365
2015 ENERVEST OPERATING LLC 643 326 365
2016 ENERVEST OPERATING LLC 616 318 366
2017 ENERVEST OPERATING LLC 630 300 365
2018 ENERVEST OPERATING LLC 590 330 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 POMINEX INC Brine 0 0
1985 POMINEX INC Brine 750 365
1986 POMINEX INC Brine 423 365
1987 POMINEX INC Brine 0 365
1988 POMINEX INC Brine 585 365
1989 CGAS EXPLORATION Brine 525 365
2000 CGAS EXPLORATION Brine 195 365
2001 CGAS EXPLORATION Brine 326 365
2002 CGAS EXPLORATION Brine 247 365
2003 CGAS EXPLORATION Brine 386 365
2006 CGAS EXPLORATION Brine 0 365
2007 ENERVEST OPERATING LLC Brine 72 365
2008 ENERVEST OPERATING LLC Brine 230 365
2009 ENERVEST OPERATING LLC Brine 272 365
2010 ENERVEST OPERATING LLC Brine 184 365
2011 ENERVEST OPERATING LLC Brine 218
2012 ENERVEST OPERATING LLC Brine 198 366
2013 ENERVEST OPERATING LLC Brine 158 365
2014 ENERVEST OPERATING LLC Brine 42 365
2015 ENERVEST OPERATING LLC Brine 32 365
2016 ENERVEST OPERATING LLC Brine 124 366
2017 ENERVEST OPERATING LLC Brine 61 365
2018 ENERVEST OPERATING LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1083759814 2018-02-01 Production Wells No Violations Status check inspection of this Clinton Sandstone well. My inspection found the wellhead equipped with 2.375 tubing and rods and operating with the aid of an electric powered pumping unit. A gauge on the tubing indicates a pressure of 60psi. This well produces to a diked tank battery on location and is shared with the South Slagle Unit #1 (PN#22761). The battery contains three (3) 100 barrel tanks, a concrete brine vault, and a vertical separator with the associated meter run. There is a domestic tap and meter on the separator sales line and the required ID is posted at the tank battery and at the wellhead. No violations.

For data sources see[9]

References