If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Geauga_County,_Ohio|Geauga]] | | County: [[Geauga_County,_Ohio|Geauga]] | ||
|- | |- | ||
− | | Municipality: [[Middlefield | + | | Municipality: [[Middlefield,_Geauga_County,_Ohio|Middlefield]] |
|- | |- | ||
| Operator Name: [[PETROX, INC]] | | Operator Name: [[PETROX, INC]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: 41.453215840 |
|- | |- | ||
| Longitude: -81.05737594 | | Longitude: -81.05737594 |
Well ID: 34-055-20523 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.45321584,"lon":-81.05737594,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Middlefield | |
Operator Name: PETROX, INC | |
Well Pad ID: | |
Farm/Lease Name: AIRPORT INDUSTRIAL PARK UNIT | |
License Status: Producing | |
License Date: 1983-07-18 | |
Spud Date: 1983-08-07 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 1983-08-15 | |
Well Total Depth: 4164 ft | |
Configuration: Vertical | |
Latitude: 41.453215840 | |
Longitude: -81.05737594 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1983-06-23 | 263 GENERAL ELEC CO GeoDate 6/23/83 |
Oil and Gas | 1983-06-23 | Issued Date 6/23/83 Expired Date 12/20/83 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1983-07-18 | 263 GENERAL ELEC CO GeoDate 7/18/83 |
Oil and Gas | 1983-07-18 | Issued Date 6/23/83 Expired Date 12/20/83 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04164 Proposed Drill Depth 04164 |
Original Spud | 1983-08-07 | R.L. 7-23-83 |
Completed | 1983-08-15 | R.L. 7-23-83 |
Reached Total Depth | 1983-08-15 | R.L. 7-23-83 |
Completion Report Received | 1983-10-31 | R.L. 7-23-83 |
Construction Permit Expires | 1983-12-20 | R.L. 7-23-83 |
Change of Owner | 2006-04-12 | Operator changed from 263, GE CONSUMER & INDUSTRIAL to 1966, PETROX, INC |
Last Compliance Report | 2015-01-05 | R.L. 7-23-83 |
Record Last Modified | 2017-08-18 | R.L. 7-23-83 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3932 | 4043 | 0 |
2006-09-11 | 3954 | 4062 | 22 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 300 Mscf | 0 | |||
H2O | 0 | 1000 Bbl | 92000 | FRAC;1000BBL H2O,92M# SD,300MCF N2 |
For data sources see[4]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | GE CONSUMER & INDUSTRIAL | Brine | 0 | 0 |
1985 | GE CONSUMER & INDUSTRIAL | Brine | 138 | 0 |
1986 | GE CONSUMER & INDUSTRIAL | Brine | 95 | 365 |
1987 | GE CONSUMER & INDUSTRIAL | Brine | 59 | 365 |
1988 | GE CONSUMER & INDUSTRIAL | Brine | 56 | 365 |
1989 | GE CONSUMER & INDUSTRIAL | Brine | 88 | 365 |
1991 | GE CONSUMER & INDUSTRIAL | Brine | 87 | 365 |
1992 | GE CONSUMER & INDUSTRIAL | Brine | 61 | 365 |
1994 | GE CONSUMER & INDUSTRIAL | Brine | 45 | 260 |
1995 | GE CONSUMER & INDUSTRIAL | Brine | 22 | 260 |
1996 | GE CONSUMER & INDUSTRIAL | Brine | 47 | 260 |
1997 | GE CONSUMER & INDUSTRIAL | Brine | 73 | 260 |
1998 | GE CONSUMER & INDUSTRIAL | Brine | 95 | 365 |
2000 | GE CONSUMER & INDUSTRIAL | Brine | 52 | 365 |
2001 | GE CONSUMER & INDUSTRIAL | Brine | 25 | 365 |
2002 | GE CONSUMER & INDUSTRIAL | Brine | 0 | 365 |
2003 | GE CONSUMER & INDUSTRIAL | Brine | 0 | 365 |
2004 | GE CONSUMER & INDUSTRIAL | Brine | 0 | 365 |
2005 | GE CONSUMER & INDUSTRIAL | Brine | 0 | 365 |
2006 | GE CONSUMER & INDUSTRIAL | Brine | 0 | 365 |
2007 | PETROX, INC | Brine | 365 | |
2008 | PETROX, INC | Brine | 0 | 100 |
2009 | PETROX, INC | Brine | 31 | 31 |
2010 | PETROX, INC | Brine | 61 | 365 |
2011 | PETROX, INC | Brine | 81 | 365 |
2012 | PETROX, INC | Brine | 122 | 366 |
2013 | PETROX, INC | Brine | 114 | 365 |
2014 | PETROX, INC | Brine | 62 | 365 |
2015 | PETROX, INC | Brine | 0 | 0 |
2016 | PETROX, INC | Brine | 104 | 365 |
2017 | PETROX, INC | Brine | 35 | 0 |
2018 | PETROX, INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0521008759 | 2017-06-27 | Production Wells | No Violations | At the time of this inspection, the well was equipped with an electric motor on the pumpjack and the valves on the wellhead were open. The well was fenced. The production records for this well were current. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a heater treater separator. Valves on the separator were open. The tank battery was diked and fenced with a locked man door. Proper, legible signage was located at the tank battery and the lease access was stable. No violations observed. |
1241992294 | 2007-09-26 | Annular Disposal | No Violations | Well is a pump jack, fenced and in good repair. One 210 and one 100 BBL tank in battery. Heat treat separator in battery. Battery is fenced, signed and locked. No annular disposal equipment noted on site. |
1415027752 | 2014-11-03 | Production Wells | No Violations | My inspection found the well to be equipped with a pumpjack. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery and the well. The lease road is in stable condition. |
1832722418 | 2017-06-27 | Annular Disposal | No Violations | During this inspection, the well was equipped with a pumpjack and no annular disposal was present. |
1964887423 | 2012-09-24 | Annular Disposal | No Violations | The unit consists of a 2-tank battery (TB) with mechanical separator. The spacing is in accordance with the rule, and the valving and mechanicals are in good repair. I did not observe any signs of leaking product or gas vapors. There is no annular disposal. The tank battery dike is adequate. The unit ID is good. No violations noted. |
For data sources see[9]