{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.642875,"lon":-75.943831,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Lemon Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 146454 | |
Farm/Lease Name: W & L WILSON UNIT 2H | |
License Status: | |
Spud Date: 2013-10-09 | |
Permit Date: 2013-08-12 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.642875 | |
Longitude: -75.943831 |
Date | Event |
---|---|
2013-08-12 | New Permit Application |
2013-10-11 | Performed Spud Operation |
2013-11-05 | Drilling Completion |
2013-12-07 | Perforation |
2013-12-07 | Performed Stimulation |
2014-05-07 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-12-07 | 2013-12-11 | 7,552 | 4,969,480 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.02 | 0 |
Water | Provided by Customer | Base Fluid | Fresh Water | 0000-00-0 | 100 | 99.88 | 0 | |
BA-40L | Halliburton | Buffering Agent | Potassium Carbonate | 584-08-7 | 60 | 0.0005 | 0 | |
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10 | 0.001 | 0 | |
Bactron K-139 | Champion Technologies | Biocide | Ethanol | 64-17-5 | 5 | 0.002 | 0 | |
Glutaraldehyde | 111-30-8 | 5 | 0.002 | 0 | ||||
Quaternary ammonium compounds, benzyl-C-12-16 alkyldimethyl, chlorides |
68424-85-1 | 10 | 0.004 | 0 | ||||
Hydrochloric Acid 10-30% | Halliburton | Acid | Hydrochloric Acid | 7647-01-0 | 30 | 0.1 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-12-07 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHIEF OIL & GAS LLC | 51,837.00 | 6 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 2,060,547.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 1,082,919.35 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 754,237.25 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 810,126.54 | 331 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 549,800.97 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 383,075.10 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | CHIEF OIL & GAS LLC | Drill Cuttings | 264.75 Tons | LANDFILL | 301358 |
2013 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 1,090.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | CHIEF OIL & GAS LLC | Drill Cuttings | 745.00 Tons | LANDFILL | 100933 |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 439.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 788.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 240.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 2,706.51 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 428.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 329.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 110.94 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 34.95 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 136.36 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 71.71 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2215221 | Primary Facility | 2013-10-22 | Drilling/Alteration | No Violations Noted | Sidewinder 58, Comp Man - Johnny Foller, @595' |
2217534 | Primary Facility | 2013-10-25 | Routine/Complete Inspection | No Violations Noted | Mr. Tripp informed me of a (3-4) barrel capacity spill that occurred at the site on 10/24/13 between 11-12 PM. Overpressurization resulted in a loss of drilling fluid out of the well. The loss of the drilling fluid occurred between the main shakers and drying shakers. The fluid was intended to be deposited into a storage container (drill cuttings bin) on containment. The fluid flowed under the bin and spread across the containment. A portion of the fluid escaped containment and impacted the ground surface from the edge of the drilling rig secondary containment berm to the base of the site perimeter earthen berm. Some of the fluid pooled next to a compressor and a tote on a pallet storing equipment and the secondary containment for the production equipment. Pelcatch, otherwise known as suck it up, was used to absorb the fluid on the ground surface. The only additive used during drilling of the surface string is a gel consiting of clay and gel sweeps are used to get cuttings out of the hole. Most of the spill occured on containment. |
2233109 | Primary Facility | 2013-12-30 | Routine/Complete Inspection | No Violations Noted | Flowback procedures were in progress for the 2H well. Mr. Daugherty stated flowback commenced on 12/27/13. Stimulation of the wells was completed about 2-3 weeks ago according to Mr. Berkey. The 1H well is in production. The production secondary containment system and associated equipment has not been completely set up. I observed several petroleum like rainbow sheens in ponded water on the secondary containment liner in a relatively close proximity to the flowback separation equipment and the wellheads. Mr. Berkey ensured me the water on containment from the recent rain event will be removed from the site including the sheens. At the end of the insepction Mr. Daugherty stated a vacuum truck is en route to the site to vacuum the water on containment. I observed some areas of compromised liner integrity, but overall the liner appeared to be in relatively good condition following well stimulation procedures. There were no elevated conductivity readings of concern in any areas in standing water on and off containment. |
2486576 | Primary Facility | 2016-05-23 | Routine/Complete Inspection | No Violations Noted | |
2494899 | Primary Facility | 2016-06-09 | Follow-up Inspection | No Violations Noted | |
2546832 | Primary Facility | 2016-12-22 | Routine/Complete Inspection | No Violations Noted | |
2668294 | Primary Facility | 2017-12-05 | Routine/Complete Inspection | No Violations Noted | This inspection is related to e-Facts Inspection ID: 2668276. There was no activity occurring at the time of the inspection. If you have any questions, please contact me. |
2815427 | Primary Facility | 2018-12-12 | Routine/Complete Inspection | No Violations Noted | After performing an administrative review of the plan and a site inspection, I agree that site conditions meet the requirements for the termination of this permit. |
For data sources see[9]