X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-28674

Well Details

Well ID: 37-129-28674
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Derry Township
Operator Name: XPR RESOURCES LLC
Well Pad ID: 145142
Farm/Lease Name: DURALIA
License Status: Active
Spud Date: 2013-04-28
Permit Date: 2011-09-12
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.376706
Longitude: -79.280289

For data sources see[1][2][3]

Well History

Date Event
2011-09-12 New Permit Application
2012-09-13 Permit Renewal Application
2013-02-28 Performed Spud Operation
2013-05-18 Drilling Completion
2013-08-15 Perforation
2013-08-30 Perforation
2013-08-31 Perforation
2019-12-03 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-08-29 2013-08-31 8,393 3,116,170 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SAND - COMMON WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 2.26973 667140
HYDROCHLORIC ACID 10-30% Halliburton Solvent Hydrochloric acid 7647-01-0 30 0.0365393 10740
SAND - PREMIUM WHITE Halliburton Proppant Crystalline silica, quartz 14808-60-7 100 8.41284 2,472,780.0
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distillate 64742-47-8 30 0.0289477 8509
LP-65 Halliburton Scale Inhibitor Ammonium chloride 12125-02-9 10 0.00465303 1368
SP BREAKER Halliburton Breaker Sodium persulfate 7775-27-1 100 0.00004253 13
LGC-36 UC Halliburton Liquid Gel Concentrate Guar gum 9000-30-0 60 0.00192867 567
Naphtha, hydrotreated heavy 64742-48-9 60 0.00192867 567
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00423032 1244
Fresh Water Operator Base Fluid Fresh Water 7732-18-5 100 88.4184 25,988,800.0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Propargyl alcohol 107-19-7 10 0.00007059 21
Methanol 67-56-1 60 0.00042353 125
HYDROCHLORIC ACID 5-10% Halliburton Solvent Hydrochloric acid 7647-01-0 10 0.0587894 17280
Other Ingredient(s) Fatty acids, tall oil Confidential 0 0.000211765 63
Fatty alcohol polyglycol ether surfactant 9043-30-5 0 0.00003214 10
Formaldehyde 50-00-0 0 0.000465303 137
Polyacrylamide copolymer Confidential 0 0.0289477 8509
Alcohols, C12-16, ethoxylated 68551-12-2 0 0.00482462 1419
Reaction product of acetophenone,
formaldehyde, thiourea
and oleic acid in dimethyl formamide
68527-49-1 0 0.000211765 63
Sodium chloride 7647-14-5 0 0.00482462 1419
Sorbitan, mono-9-octadecenoate, (Z) 1338-43-8 0 0.000964924 284
Olefins Confidential 0 0.00000706 3
Alcohols, C14-C15, ethoxylated 68951-67-7 0 0.000211765 63
Sodium sulfate 7757-82-6 0 0.00000004 1
Crystalline silica, quartz 14808-60-7 0 0.00000321 1
Quaternary ammonium compounds,
bis(hydrogenated tallow alkyl)
dimethyl,salts with bentonite
68953-58-2 0 0.000160722 48
Organic phosphonate Confidential 0 0.0279182 8206
Olefins Confidential 0 0.00003529 11
Fatty acid tall oil amide Confidential 0 0.00482462 1419
Sorbitan monooleate polyoxyethylene derivative 9005-65-6 0 0.000964924 284
Ammonium chloride 12125-02-9 0 0.00482462 1419
Water 7732-18-5 0 0.837809 246257

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
1 3,116,171 0 0
2 3,116,171 0 0
3 3,116,171 0 0
4 3,116,171 0 0
5 3,116,171 0 0
6 3,116,171 0 0
7 3,116,171 0 0
8 3,116,171 0 0
9 3,116,171 0 0
10 3,116,171 0 0
11 3,116,171 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2013 XPR RESOURCES LLC 147,559.67 61 0.00 0 0.00 0
2014 XPR RESOURCES LLC 498,628.35 365 0.00 0 0.00 0
2015 XPR RESOURCES LLC 249,077.04 365 0.00 0 0.00 0
2016 XPR RESOURCES LLC 170,608.01 365 0.00 0 0.00 0
2017 XPR RESOURCES LLC 127,602.22 364 0.00 0 0.00 0
2018 XPR RESOURCES LLC 114,769.00 365 0.00 0 0.00 0
2019 XPR RESOURCES LLC 99,102.00 356 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 XPR RESOURCES LLC Fracing Fluid Waste 5,548.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2013 XPR RESOURCES LLC Produced Fluid 6,537.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2013 XPR RESOURCES LLC Drill Cuttings 1,096.71 Tons LANDFILL 301071
2014 XPR RESOURCES LLC Produced Fluid 3,970.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XPR RESOURCES LLC Produced Fluid 1,128.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 660.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 755.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2017 XPR RESOURCES LLC Produced Fluid 672.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 XPR RESOURCES LLC Produced Fluid 220.00 Bbl REUSE (AT WELL PAD)
2017 XPR RESOURCES LLC Produced Fluid 125.71 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2018 XPR RESOURCES LLC Produced Fluid 245.71 Bbl REUSE (AT WELL PAD)
2018 XPR RESOURCES LLC Produced Fluid 689.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XPR RESOURCES LLC Produced Fluid 15.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XPR RESOURCES LLC Produced Fluid 449.98 Bbl REUSE (AT WELL PAD)
2019 XPR RESOURCES LLC Produced Fluid 109.29 Bbl INJECTION DISPOSAL WELL 34-155-24079

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2013969 Primary Facility 2011-10-26 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection.
2019651 Primary Facility 2011-11-16 Routine/Complete Inspection No Violations Noted Fred Webb and Jimmy Ballew were the company men on site. AP was tool pusher for HP.
2026858 Primary Facility 2011-12-14 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection.
2140632 Primary Facility 2013-02-19 Routine/Complete Inspection No Violations Noted no violations noted
2145822 Primary Facility 2013-02-28 Routine/Complete Inspection No Violations Noted Butches Rathole getting set up to spud 8H and 10H. 4 produced fluid tanks and seperators.
2149808 Primary Facility 2013-03-13 Drilling/Alteration No Violations Noted WGM getting ready to lay down containment.
2151688 Primary Facility 2013-03-27 Drilling/Alteration No Violations Noted 3/26/2013 Moving rig onto location.
2161067 Primary Facility 2013-04-24 Routine/Complete Inspection No Violations Noted At the time of inspection the Department notes the drill rig was onsite and placed on secondary containment. The Operator indicated that the rig would be skidding to this well in the next 24 hours. The Erosion and Sedimentation Plan was onsite and appeared to be implemented as designed. No sign of accelerated erosion or sedimentation observed in relation to the well pad or access road during the inspection. The impoundment associated with the well also appears to be in sound condition and had the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained.
2162327 Primary Facility 2013-04-02 Drilling/Alteration No Violations Noted 4/2/2013 drilling on the 1-8H.
2164834 Primary Facility 2013-04-02 Drilling/Alteration No Violations Noted
2164835 Primary Facility 2013-05-07 Drilling/Alteration No Violations Noted 4/7/2013 Orion drilling at 4308'.
2167552 Primary Facility 2013-05-07 Drilling/Alteration No Violations Noted 5/7/2013 Orion drilling at 4308'.
2171365 Primary Facility 2013-06-03 Routine/Complete Inspection No Violations Noted At the time of inspection the Department notes the drill rig was onsite and placed on secondary containment. The Operator indicated that this well has been drilled to total depth. The Erosion and Sedimentation Plan was onsite and appeared to be implemented as designed. No sign of accelerated erosion or sedimentation observed in relation to the well pad or access road during the inspection. The impoundment associated with the well also appears to be in sound condition and had the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained.
2173881 Primary Facility 2013-05-30 Drilling/Alteration No Violations Noted 5/30/2013 Orion drilling on 1-8h 2090sks cmt. Inspected w/OGI P. Wyrwas.
2183178 Primary Facility 2013-07-11 Routine/Complete Inspection No Violations Noted At the time of inspection the Department notes the drill rig was onsite and placed on secondary containment. The Operator indicated that this well has been drilled to total depth. The Erosion and Sedimentation Plan was onsite and appeared to be implemented as designed. No sign of accelerated erosion or sedimentation observed in relation to the well pad or access road during the inspection. The impoundment associated with the well also appears to be in sound condition and had the required 2' of freeboard. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained.
2188070 Primary Facility 2013-07-25 Drilling/Alteration No Violations Noted 7/25/2013 Orion rig drilling on 1-10H.
2188072 Primary Facility 2013-07-25 Drilling/Alteration No Violations Noted 7/25/2013 Orion rig drilling on 1-10H.
2195643 Primary Facility 2013-08-12 Routine/Complete Inspection No Violations Noted See inspection #2195630 for observations made on 8/12/2013. Well appeared to be drilled however not equipped for production. The Operator was in the process to reconfiguring the well site to begin stimulation. No observation of accelerated erosion or sedimentation in relation to the well pad or access road at the time of inspection.
2208619 Primary Facility 2013-07-30 Drilling/Alteration No Violations Noted 7/30/2013 Orion rig drilling on 1-8H.
2259055 Primary Facility 2014-03-26 Routine/Complete Inspection No Violations Noted 3/26/2014 Produced fluids ttanks diked and GPU's
2274461 Primary Facility 2014-05-19 Routine/Complete Inspection No Violations Noted 5/19/2014 Produced fluids tanks, GPUs and in line.
2302588 Primary Facility 2014-08-27 Routine/Complete Inspection No Violations Noted At the time of inspection the well appeared to drilled and equipped for production. The well apparatus and brine tanks appear to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the well pad or access road at the time of inspection.
2377789 Primary Facility 2015-06-09 Routine/Complete Inspection No Violations Noted 6/9/2015 Produced fluids tanks, GPUs and in line.
2401506 Primary Facility 2015-08-20 Routine/Complete Inspection No Violations Noted 8/20/2015 Produced fluids tanks, GPUs and in line.
2444389 Primary Facility 2016-01-27 Routine/Complete Inspection No Violations Noted Access road gated and locked. At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Four brine tanks located on site within secondary containment and appear to be structurally sound. Site permanently stabilized, ground snow covered, no signs of E& S issues in relation to site and/or access road.
2449992 Primary Facility 2016-01-27 Routine/Complete Inspection No Violations Noted 1/27/2016 Produced fluids tanks, GPUs and in line.
2476122 Primary Facility 2016-04-18 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production unit equipment-tank battery-dike look ok.
2554616 Primary Facility 2017-01-24 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2556702 Primary Facility 2017-01-26 Routine/Complete Inspection No Violations Noted At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Four brine tanks located on site within secondary containment and appear to be structurally sound. Site permanently stabilized, no E& S issues in relation to site and/or access road.
2621638 Primary Facility 2017-08-02 Routine/Complete Inspection No Violations Noted Well tagged-on. Well head casing-production set equipment-tank battery-dike containment look ok.
2690447 Primary Facility 2018-02-01 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Four brine tanks within secondary containment and appear to be structurally sound. No E&S issues.

Site id sign updated to reflect current Operator information. POC plan and ERP appears to reflect outdated Operator information. Department request Operator update documents accordingly in accordance with regulation. Violation issued (see inspection id 2690435).

2834647 Primary Facility 2019-01-28 Site Restoration No Violations Noted Inspection conducted in response to a Post-drilling Well Site Restoration Report received by Department.

The NOT for this site was approved on 6-15-18. At time of inspection well appears equipped for production. Well head protected by cement posts (photo #2). Four brine tanks on site. Site appears vegetated and returned to near original contours. The Post-drilling Well Site Restoration Report is approved.

For data sources see[9]

References