X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-125-27879

Well Details

Well ID: 37-125-27879
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Carroll Township
Operator Name: EQT PROD CO
Well Pad ID: 148479
Farm/Lease Name: HAYWOOD 593808
License Status:
Spud Date:
Permit Date: 2016-02-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.178619
Longitude: -79.975933

For data sources see[1][2][3]

Well History

Date Event
2016-02-10 New Permit Application
2016-05-16 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-05-20 2017-06-07 7,718 19,697,500 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Keane Proppant Listed Below
KFR-23 Keane Friction Reducer Water 7732-18-5 50 0.0291959 55427.8
MC MX 5-3886 Multi-Chem Specialty Brine Listed Below
KFR-20 Keane Friction Reducer Listed Below
Hydrochloric Acid (15%) Keane Acidizing Listed Below
KWBO-2 Keane Breaker Listed Below
LD-2250 Mult-Chem Friction Reducer Listed Below
KAI-12 Keane Acid Inhibitor Listed Below
Water Keane Carrier/Base Fluid Water 7732-18-5 100 86.5829 164,376,000.0
Sodium Chloride 7647-14-5 100 0.00945956 17958.8
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.00238062 4519.55
Trade Secret Proprietary 10 0.00003520 66.827
Oleic Acid Diethanolamide 93-83-4 2 0.00004791 90.962
prop-2-yn-1-ol 107-19-7 5 0.00001111 21.093
Alcohols, C7-9iso-, C8-rich 68526-83-0 5 0.00001111 21.093
Petroleum Distillate 64742-47-8 20 0.000479132 909.622
Calcium Nitrate.4H20 13477-34-4 100 0.106668 202507
Sodium Chloride 7647-14-5 10 0.000152717 289.93
copolymer of 2-propenamide 69418-26-4 20 0.0116784 22171.1
Inner Salt of Alkyl Amines Proprietary 60 0.0009163 1739.58
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00004791 90.962
Ammonium chloride ((NH4)CI) 12125-02-9 1 0.00002396 45.481
Sodium Chloride 7647-14-5 5 0.000396769 753.259
Sodium persulfate 7775-27-1 99 0.00003948 74.949
Polyacrylate Proprietary 30 0.00238062 4519.55
2-butoxyethanol 111-76-2 20 0.000127473 242.005
Sodium Chloride 7647-14-5 100 0.00945956 17958.8
copolymer of 2-propenamide 69418-26-4 30 0.000718697 1364.43
Fatty Nitrogen Derived Amides Proprietary 5 0.000396769 753.259
Solvent naphtha (petroleum) heavy aliph. 64742-96-7 60 0.000211201 400.961
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.0116784 22171.1
Fatty Nitrogen Derived Amides Proprietary 5 0.000396769 753.259
Sodium Nitrate 7631-99-4 5 0.000472978 897.939
Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.00238062 4519.55
methanol 67-56-1 30 0.00622954 11826.7
polyethylene glycol nonylphenyl ether, liquids 9016-45-9 25 0.000159341 302.506
Silica Substrate 14808-60-7 100 13.0573 24,789,000.0
Sodium Chloride 7647-14-5 10 0.000152717 289.93
Calcium Nitrate.4H20 13477-34-4 100 0.106668 202507
Sodium Chloride 7647-14-5 5 0.000396769 753.259
Guar gum 9000-30-0 60 0.000211201 400.961
Ethoxylated Alcohol Proprietary 5 0.000396769 753.259
Ammonium persulfate 7727-54-0 13 0.00005170 98.146
Ethylene glycol 107-21-1 13 0.00005170 98.146
isopropyl alcohol 67-63-0 5 0.00001111 21.093
Ammonium chloride ((NH4)CI) 12125-02-9 1 0.00002396 45.481
Trade Secret Proprietary 10 0.00003520 66.827
Polyacrylate Proprietary 30 0.00238062 4519.55
Inner Salt of Alkyl Amines Proprietary 60 0.0009163 1739.58
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00116784 2217.11
Petroleum Distillate 64742-47-8 20 0.000479132 909.622
ethylbenzene 100-41-4 1 0.00000222 4.219
Solvent naphtha (petroleum) heavy aliph. 64742-96-7 60 0.000211201 400.961
2-ethylhexanol 104-76-7 5 0.00003187 60.501
2-butoxyethanol 111-76-2 20 0.000127473 242.005
Ammonium persulfate 7727-54-0 13 0.00005170 98.146
Sodium persulfate 7775-27-1 99 0.00003948 74.949
xylene 1330-20-7 5 0.00001111 21.093
Sodium Nitrate 7631-99-4 5 0.000472978 897.939
methanol 67-56-1 90 0.000199988 379.674
copolymer of 2-propenamide 69418-26-4 30 0.000718697 1364.43
Guar gum 9000-30-0 60 0.000211201 400.961
oleic acid diethanolamide 93-83-4 2 0.00116784 2217.11
Ethylene glycol 107-21-1 13 0.00005170 98.146
Ethoxylated Alcohol Proprietary 5 0.000396769 753.259
2-ethylhexanol 104-76-7 5 0.00003187 60.501
Oleic Acid Diethanolamide 93-83-4 2 0.00004791 90.962
Hydrochloric Acid 7647-01-0 15 0.0226521 43004.6
Fatty imidazoline 61790-69-0 5 0.00001111 21.093
polyethylene glycol nonylphenyl ether, liquids 9016-45-9 25 0.000159341 302.506
alcohols, C12-16, ethoxylated 68551-12-2 2 0.00004791 90.962
ethylbenzene 100-41-4 1 0.00000222 4.219
KWG-111L Keane Gelling Agent Listed Below
Other Chemical(s) Listed Above See Trade Name(s) List water 7732-18-5 60 0.000382419 726.015
Water 7732-18-5 45 0.00107805 2046.65
MC MX 5-2349 Multi-Chem Friction Reducer Breaker Water 7732-18-5 45 0.00107805 2046.65
water 7732-18-5 60 0.000382419 726.015
KFR-Activator-1 Keane Activator Listed Below
LD-2550 Multi-Chem Additive Listed Below
KSI-19 Keane Scale Inhibitor Listed Below
MC MX 8-2544 Multi-Chem Live Culture - Nitrate Reducing Bacteria Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 EQT PROD CO 0.00 0 0.00 0 0.00 0
2017 EQT PROD CO 3,056,061.00 175 0.00 0 0.00 0
2018 EQT PROD CO 3,985,421.00 342 0.00 0 0.00 0
2019 EQT PROD CO 2,017,064.00 359 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 EQT PROD CO Synthetic Liner Materials 1.46 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 871.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Other Oil & Gas Wastes 660.00 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Other Oil & Gas Wastes 40.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 EQT PROD CO Waste Water Treatment Sludge 50.18 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EQT PROD CO Other Oil & Gas Wastes 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 22.85 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 EQT PROD CO Drilling Fluid Waste 930.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EQT PROD CO Produced Fluid 1,335.11 Bbl REUSE (AT WELL PAD)
2017 EQT PROD CO Drill Cuttings 806.84 Tons LANDFILL 100419
2017 EQT PROD CO Produced Fluid 80.48 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 EQT PROD CO Other Oil & Gas Wastes 6.67 Bbl RESIDUAL WASTE PROCESSING FACILITY
2018 EQT PROD CO Other Oil & Gas Wastes 0.95 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Produced Fluid 34.04 Bbl INJECTION DISPOSAL WELL 34-157-25511
2018 EQT PROD CO Produced Fluid 2,846.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Other Oil & Gas Wastes 2.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE ORDER 2016-415
2018 EQT PROD CO Other Oil & Gas Wastes 5.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EQT PROD CO Produced Fluid 1,464.59 Bbl REUSE (AT WELL PAD)
2018 EQT PROD CO Other Oil & Gas Wastes 40.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018 EQT PROD CO Produced Fluid 309.85 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 EQT PROD CO Other Oil & Gas Wastes 309.41 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 9.75 Bbl RESIDUAL WASTE PROCESSING FACILITY
2019 EQT PROD CO Produced Fluid 62.09 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019 EQT PROD CO Other Oil & Gas Wastes 4.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Produced Fluid 2,452.79 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 199.08 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW010
2019 EQT PROD CO Other Oil & Gas Wastes 40.71 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 48.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 EQT PROD CO Produced Fluid 200.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2019 EQT PROD CO Other Oil & Gas Wastes 185.99 Bbl REUSE (AT WELL PAD)
2019 EQT PROD CO Produced Fluid 38.68 Bbl SURFACE IMPOUNDMENT 95-7-37312-19

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2484802 Primary Facility 2016-05-17 Drilling/Alteration No Violations Noted Cellar Tech auger rig

Drilled a 30” wellbore and set 26” conductor casing at 65 ft. on 5/17/16.

2522507 Primary Facility 2016-09-15 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Moved onto this well and resumed drilling at 65 ft. The 18 5/8” casing was set at 378 ft. on 9/14/16 and cemented to surface with 50 bbls returned. The 13 3/8” casing was set at 479 ft. on 9/15/16 and cemented to surface with 29 bbls returned. Coal was found from 425 ft. to 430 ft. A basket was set at 391 ft. Currently at 530 ft.

2522509 Primary Facility 2016-09-15 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

TD at 5950 ft. on 5/13/16.

2522512 Primary Facility 2016-09-23 Drilling/Alteration No Violations Noted Alpha Hunter Drilling Rig #8

Set the 9 5/8” casing at 2091 ft. on 9/17/16 and cemented to surface with 57 bbls returned. The Casing Annulus Packer was set in the 9 5/8” casing string from 1265 ft. to 1287 ft. (with a 7 ft. pup joint above the packer and a 1.5 ft. pup joint below). TD was at 5650 ft. on 9/21/16.

2548583 Primary Facility 2016-12-29 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

Moved onto this well on 12/26/16 and resumed drilling at 5660 ft. MD. Currently at 6924 ft. and building curve.

2549506 Primary Facility 2016-12-06 Routine/Partial Inspection No Violations Noted On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:

•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation.

2551319 Primary Facility 2017-01-06 Drilling/Alteration No Violations Noted Pioneer Drilling Rig #72

EOB was at 9608 ft. MD (7709.74 ft. TVD). Currently at 20,521 ft. MD and drilling ahead.

2553005 Primary Facility 2016-12-16 Follow-up Inspection No Violations Noted On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:

•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code

2586966 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.

>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended.

>A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended.

> Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway.

> The AST remained on site at time of inspection.

2688485 Primary Facility 2018-01-30 Routine/Complete Inspection No Violations Noted On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:

>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation.

>>Wells on site appeared to be in various stages of completion with no rig on site.

2698986 Primary Facility 2017-09-05 Administrative/File Review No Violations Noted On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity.
2722645 Primary Facility 2018-03-27 Complaint Inspection No Violations Noted On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis.
2767377 Primary Facility 2018-08-15 Routine/Partial Inspection No Violations Noted On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:

>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection.

>>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations.

>>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola

2790123 Primary Facility 2018-05-01 Administrative/File Review No Violations Noted On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present.
2805726 Primary Facility 2018-11-02 Incident- Response to Accident or Event No Violations Noted On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:

>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad.

>>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera

2831247 Primary Facility 2019-01-22 Compliance Evaluation No Violations Noted On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:

>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation.

>>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time.

>>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing.

2845258 Primary Facility 2019-02-19 Routine/Complete Inspection No Violations Noted Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank.
2863287 Primary Facility 2018-09-07 Administrative/File Review No Violations Noted On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found.

For data sources see[8]

References