If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-27492 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.229197,"lon":-80.031908,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Nottingham Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149501 | |
Farm/Lease Name: HARBISON 592591 | |
License Status: Active | |
Spud Date: 2015-01-22 | |
Permit Date: 2014-10-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.229197 | |
Longitude: -80.031908 |
Date | Event |
---|---|
2014-10-17 | New Permit Application |
2015-01-22 | Performed Spud Operation |
2015-06-02 | Drilling Completion |
2015-10-18 | Perforation |
2015-10-18 | Performed Stage 1 of Stimulation |
2015-10-19 | Perforation |
2015-10-19 | Performed Stage 2 of Stimulation |
2015-10-19 | Performed Stage 3 of Stimulation |
2015-10-19 | Performed Stage 4 of Stimulation |
2015-10-19 | Performed Stage 5 of Stimulation |
2015-10-19 | Performed Stage 6 of Stimulation |
2015-10-19 | Performed Stage 7 of Stimulation |
2015-10-20 | Perforation |
2015-10-20 | Performed Stage 10 of Stimulation |
2015-10-20 | Performed Stage 11 of Stimulation |
2015-10-20 | Performed Stage 12 of Stimulation |
2015-10-20 | Performed Stage 8 of Stimulation |
2015-10-20 | Performed Stage 9 of Stimulation |
2015-10-21 | Perforation |
2015-10-21 | Performed Stage 13 of Stimulation |
2015-10-21 | Performed Stage 14 of Stimulation |
2015-10-21 | Performed Stage 15 of Stimulation |
2015-10-21 | Performed Stage 16 of Stimulation |
2015-10-21 | Performed Stage 17 of Stimulation |
2015-10-21 | Performed Stage 18 of Stimulation |
2015-10-22 | Perforation |
2015-10-22 | Performed Stage 19 of Stimulation |
2015-10-22 | Performed Stage 20 of Stimulation |
2015-10-22 | Performed Stage 21 of Stimulation |
2015-10-22 | Performed Stage 22 of Stimulation |
2015-10-22 | Performed Stage 23 of Stimulation |
2018-07-02 | Deviated |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-10-18 | 2015-10-22 | 7,637 | 4,900,980 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hydrochloric Acid (15%) | FTS International | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0357181 | 16742.2 |
Sand (Proppant) | FTS International | Proppant | Silica Substrate | 14808-60-7 | 100 | 12.3409 | 5,784,560.0 | |
NE-100 | FTS International | Non-emulsifier | Dodecylbenzenesulfonic acid | 27176-87-0 | 5 | 0.00002203 | 10.327 | |
2-Propanol | 67-63-0 | 10 | 0.00004406 | 20.654 | ||||
2-Butoxyethanol | 111-76-2 | 10 | 0.00004406 | 20.654 | ||||
CI-150 | FTS International | Acid corrosion inhibitor | Ethylene glycol | 107-21-1 | 30 | 0.00013219 | 61.962 | |
Dimethylformamide | 68-12-2 | 10 | 0.00004406 | 20.654 | ||||
Isopropanol | 67-63-0 | 30 | 0.00013219 | 61.962 | ||||
Organic amine resin salt | Proprietary | 30 | 0.00013219 | 61.962 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00004406 | 20.654 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00004406 | 20.654 | ||||
Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.2542 | 40,898,700.0 | |
FRW-900 | FTS International | Friction reducer | Oxyalkylated alcohol A | Proprietary | 5 | 0.00235025 | 1101.63 | |
Alkyl alcohol | Proprietary | 10 | 0.0047005 | 2203.26 | ||||
Hydrotreated light distillate | 64742-47-8 | 30 | 0.0141015 | 6609.79 | ||||
FE-100L | FTS International | Iron control | Citric acid | 77-92-9 | 55 | 0.00084925 | 398.069 | |
MC MX 437-5 | Multi-Chem Group LLC | Calcium nitrate solution | Calcium nitrate | 10124-37-5 | 60 | 0.0559017 | 26202.8 | |
CS-500-SI | FTS International | Scale inhibitor | Ethylene glycol | 107-21-1 | 10 | 0.00241357 | 1131.32 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-10-18 | 1 | 4,672,920 | 0 | 0 | |
2015-10-19 | 2 | Sand | 4,672,920 | 8,022 | 8,410 |
2015-10-19 | 3 | Sand | 4,672,920 | 8,299 | 8,571 |
2015-10-19 | 4 | Sand | 4,672,920 | 8,295 | 8,496 |
2015-10-19 | 5 | Sand | 4,672,920 | 8,551 | 8,984 |
2015-10-19 | 6 | Sand | 4,672,920 | 8,619 | 8,890 |
2015-10-19 | 7 | Sand | 4,672,920 | 8,589 | 8,912 |
2015-10-20 | 8 | Sand | 4,672,920 | 8,395 | 8,783 |
2015-10-20 | 9 | Sand | 4,672,920 | 8,539 | 8,786 |
2015-10-20 | 10 | Sand | 4,672,920 | 8,078 | 8,655 |
2015-10-20 | 11 | Sand | 4,672,920 | 7,897 | 6,150 |
2015-10-20 | 12 | Sand | 4,672,920 | 7,997 | 8,237 |
2015-10-21 | 13 | Sand | 4,672,920 | 8,250 | 8,425 |
2015-10-21 | 14 | Sand | 4,672,920 | 8,372 | 8,582 |
2015-10-21 | 15 | Sand | 4,672,920 | 8,559 | 8,860 |
2015-10-21 | 16 | Sand | 4,672,920 | 8,751 | 8,907 |
2015-10-21 | 17 | Sand | 4,672,920 | 8,382 | 8,866 |
2015-10-21 | 18 | Sand | 4,672,920 | 8,060 | 8,182 |
2015-10-22 | 19 | Sand | 4,672,920 | 7,641 | 8,126 |
2015-10-22 | 20 | Sand | 4,672,920 | 7,857 | 7,998 |
2015-10-22 | 21 | Sand | 4,672,920 | 7,793 | 8,105 |
2015-10-22 | 22 | Sand | 4,672,920 | 8,087 | 8,566 |
2015-10-22 | 23 | Sand | 4,672,920 | 8,138 | 8,997 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 745,556.00 | 145 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 528,585.00 | 346 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 375,055.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 297,713.00 | 357 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | EQT PROD CO | Drilling Fluid Waste | 130.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drill Cuttings | 406.00 Tons | LANDFILL | 100663 |
2015 | EQT PROD CO | Fracing Fluid Waste | 39.39 Bbl | LANDFILL | SWF 1032-WV0109 |
2015 | EQT PROD CO | Fracing Fluid Waste | 2,800.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drill Cuttings | 559.00 Tons | LANDFILL | 100172 |
2016 | EQT PROD CO | Fracturing Fluid Waste | 125.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016 | EQT PROD CO | Produced Fluid | 260.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 1,970.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 26,583.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | EQT PROD CO | Produced Fluid | 1,110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 300.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 2,562.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 76.00 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 2.85 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2018 | EQT PROD CO | Produced Fluid | 135.03 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 110.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 234.87 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Produced Fluid | 71.86 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Produced Fluid | 200.91 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 11.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 6.58 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Produced Fluid | 8.66 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Produced Fluid | 7.96 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ORDER 2016-415 |
2019 | EQT PROD CO | Produced Fluid | 144.45 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 5.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 106.72 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 8.88 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2014-4 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 16.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 3.97 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 1.09 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2019 | EQT PROD CO | Produced Fluid | 342.40 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 12.43 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 0.70 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2019 | EQT PROD CO | Produced Fluid | 41.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2339081 | Primary Facility | 2015-01-27 | Drilling/Alteration | No Violations Noted | Himes Diversified auger rig |
2351686 | Primary Facility | 2015-03-13 | Drilling/Alteration | No Violations Noted | Alpha Hunter Drilling Rig #4 |
2353184 | Primary Facility | 2015-03-19 | Drilling/Alteration | No Violations Noted | Alpha Hunter Drilling Rig #4 |
2380617 | Primary Facility | 2015-06-19 | Drilling/Alteration | No Violations Noted | Orion Drilling Rig #17 |
2410183 | Primary Facility | 2015-08-28 | Routine/Complete Inspection | No Violations Noted | On 8/28/15, I performed a routine inspection on the Vivian Harbison site and made the following observations: |
2602680 | Primary Facility | 2017-06-07 | Routine/Complete Inspection | No Violations Noted | |
2685508 | Primary Facility | 2018-01-10 | Administrative/File Review | No Violations Noted | Operator production crew servicing well. |
2700217 | Primary Facility | 2018-02-26 | Routine/Complete Inspection | No Violations Noted | This well has been completed and is now producing. |
2720043 | Primary Facility | 2018-04-19 | Incident- Response to Accident or Event | In Compliance with Policy | On 4/19/18 an incident inspection of the Vivian Harbison Well Site was conducted in response to CTS ID: 333587. The following was observed:
>>On 4/13/18 EQT's Mike Cromley reported a ten gallon spill with cleanup beginning immediately as a vacc truck was present on site at the time of the spill. >>Further communication with operator personnel indicated a spill of 10 gallons of produced water near the offloading point near the production tanks and that the spill cleanup was completed the same day. >>Site inspection found no visible evidence of contamination, cleanup appears to have been fully completed in compliance with policy. |
For data sources see[9]