If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-01201 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.163639,"lon":-80.312361,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Canton Township | |
Operator Name: DALLAS ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: MONTGOMERY J | |
License Status: Plugged and Abandoned | |
Spud Date: | |
Permit Date: | |
Well Type: OIL | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.163639 | |
Longitude: -80.312361 |
Date | Event |
---|---|
1896-06-21 | Drilling Completion |
1986-04-18 | Old Well |
2016-09-01 | Begin Plugging |
2016-10-18 | Finished Plugging |
2019-04-19 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1993 | PENNZOIL PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
1996 | PENNZOIL PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
1997 | PENNZOIL PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
1998 | PENNZOIL PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
1999 | PENNZOIL PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2000 | PENNZOIL PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2001 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2002 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2003 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2005 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2006 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2007 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | EAST RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | EAST RESOURCES MGMT LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2318486 | Primary Facility | 2014-10-03 | Routine/Complete Inspection | No Violations Noted | Inspected well on farm off of McKee Road in Washington, PA. |
2516936 | Primary Facility | 2016-09-06 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ found obstruction in 4 3/4" casing near ground level, spudded on for a while, but would not move. SD, WO power swivel. Well began gassing after spudding. |
2518195 | Primary Facility | 2016-09-08 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ swapped out power swivel units at time of inspection. |
2527730 | Primary Facility | 2016-09-14 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ milling junk in hole @ 510 feet, well took water. SD to get more water. |
2527741 | Primary Facility | 2016-09-15 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ had wireline camera run in hole to look at obstruction- found rods & tubing in hole w/ top @ 483 feet. |
2527749 | Primary Facility | 2016-09-21 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ was able to grab fish (rods & tubing) w/ overshot tool and fish pulled free. Pulled fish to surface, began laying down rods & tubing. |
2527766 | Primary Facility | 2016-09-22 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ has 90 joints of tubing & rods out of the hole, close to having all out. |
2527801 | Primary Facility | 2016-09-26 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ starting to TIH w/ work string to spot first cement plug. |
2527818 | Primary Facility | 2016-09-29 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | Discussed CBL w/ ConServ before spotting second plug. |
2527847 | Primary Facility | 2016-09-30 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | No activity at time of inspection. All but 10 joints of work string are tripped out of well, w/ remaining left to add weight to JU head. SI until next Monday. |
2527858 | Primary Facility | 2016-10-06 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ cutting 5" casing w/ wireline to attempt to pull. |
2527859 | Primary Facility | 2016-10-13 | Plugging(Includes Plugged/Mined Through) | In Compliance with Schedule | ConServ spotted a 55 sack plug for a calculated TOC of 416 feet. |
2529528 | Primary Facility | 2016-10-18 | Routine/Complete Inspection | In Compliance with Schedule | ConServ topped-off final cement plug to surface, began to rig down. |
2529529 | Primary Facility | 2016-10-19 | Routine/Complete Inspection | In Compliance with Schedule | ConServ has rig off location, demobilizing. |
2534552 | Primary Facility | 2016-11-02 | Plugging(Includes Plugged/Mined Through) | No Adverse Event or Action Reported | ConServ plugged well, moved off location. Location remains to be graded, seeded and marker set. |
2589815 | Primary Facility | 2017-04-05 | Complaint Inspection | No Violations Noted | Today I sampled the complainants water supply due to concerns that Oil and Gas activity (SWEPI plugging project) affected the water. The water was purged for 15 minutes prior to sampling. Samples were taken before treatment and sent to the Bureau of Laboratories in Harrisburg. Sample analysis will be for standard analysis code 946 and oil/ grease. |
2614059 | Primary Facility | 2017-02-02 | Plugging(Includes Plugged/Mined Through) | In Compliance with Policy | Checked site, still needing final grading, seeded & mulch. Landowner called to question why the site was still torn up after being plugged in October. (It is because conditions were too wet at the site to properly grade, seed & mulch per ConServ). After discussing, landowner was OK. |
For data sources see[6]