X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21972

Well Details

Well ID: 37-117-21972
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Delmar Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 150926
Farm/Lease Name: DCNR 007 124HU 52689
License Status:
Spud Date:
Permit Date: 2018-03-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.808631
Longitude: -77.331669

For data sources see[1][2][3]

Well History

Date Event
2018-03-13 New Permit Application
2018-05-24 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-11-11 2019-01-04 12,283 20,283,400 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KFR-45 Keane Friction Reducer alcohols, C11-14-iso-, C13 rich, ethoxlated 78330-21-9 5 0.00513706 9521.81
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0308224 57130.9
SILV7500 Silverback Pipe on Pipe Mineral oil/ light hydrotreated pet. distillate 64742-47-8 70 0.000926546 1717.4
KAI-12 Keane Acid Inhibitor methanol 67-56-1 90 0.000695201 1288.59
fatty imidazoline 61790-69-0 5 0.00003862 71.588
xylne 1330-20-7 5 0.00003862 71.588
propan-2-ol 67-63-0 5 0.00003862 71.588
alcohols, c7-9-0so, c8-rich 68526-83-0 5 0.00003862 71.588
ethylbenzene 100-41-4 1 0.00000772 14.318
prop-2-yn-1-0l 107-19-7 5 0.00003862 71.588
Water (Clean - Acid - Chems) Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 91.1549 168,960,000.0
MBC-516W Keane Biocide ethanol 64-17-5 2.8 0.000278993 517.128
Didecyl dimethyl ammonium chloride 7173-51-5 8 0.000794135 1471.97
Other components below reportable levels Proprietary 56.7 0.00565161 10475.5
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.000529091 980.697
gluteral 111-30-8 26.7 0.0026604 4931.19
7.5% Acid Keane Acidizing Water 7732-18-5 92.5 0.278505 516224
Hydrochloric Acid 7647-01-0 7.5 0.0225815 41856
Sand (Proppant) (lbs) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 8.40925 15,587,000.0
KSI-19 Keane Scale Inhibitor Aqueous Solution Proprietary 70 0.0134912 25006.6
Methanol 67-56-1 30 0.00578193 10717.1
KFEAC-30 Keane Iron Control Acetic acid 64-19-7 60 0.000391916 726.436
Citric acid 77-92-9 40 0.000261277 484.29

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 SENECA RESOURCES CO LLC 2,391,332.37 292 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SENECA RESOURCES CO LLC Synthetic Liner Materials 4.64 Tons LANDFILL 301358
2018 SENECA RESOURCES CO LLC Produced Fluid 90.00 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 210.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Drill Cuttings 1,731.34 Tons LANDFILL 301358
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 113.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 16,512.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 295.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 6,098.40 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 565.83 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC038
2019 SENECA RESOURCES CO LLC Produced Fluid 45.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 131.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SENECA RESOURCES CO LLC Drill Cuttings 295.10 Tons LANDFILL 301358
2019 SENECA RESOURCES CO LLC Produced Fluid 3,011.00 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 171.17 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 SENECA RESOURCES CO LLC Waste Water Treatment Sludge 63.83 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Synthetic Liner Materials 19.11 Tons LANDFILL 301358
2019 SENECA RESOURCES CO LLC Produced Fluid 6,089.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 244.86 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2706018 Primary Facility 2018-03-15 Routine/Complete Inspection No Violations Noted The department of environmental protection conducted a routine inspection of the Seneca DCNR 007 pad K located in Delmar Twp, Tioga Co. on 3/15/2018 @1300 hours. The weather was 33° and overcast with light snow

Two wells, the 73H and 94H, have been drilled and are in production; drilling of the wells was completed in November 2014. The well site has not been restored. Three new well permits were issued 3/13/2018; 117-21971 (123HU), 117-21972 (124HU), 117-21973 (125HU).

Frozen water was observed in the secondary containment surrounding the production tanks. Snow remains covering most of the well pad. The site was last inspected by company personnel on March 12, 2018 as noted in the on-site inspection log.

No issues were observed during the inspection. No violations were noted at this time. I departed this site at 1400 hrs.

2742610 Primary Facility 2018-06-18 Routine/Complete Inspection No Violations Noted The DEP conducted a ROUTINE inspection of the Seneca Resources – DCNR 007 Pad K wells site located in Delmar Twp., Tioga Co. on 6/18/2018 @1300 hours. The weather was 87 degrees, 64% humidity, winds W 11mph. Rain showers in the area. Gus Trejo, GT Drilling Consultants was present for the inspection.

Seneca is in the process of drilling 6 utica wells with the Patterson 339 rig. At the time of the inspection Haliburton was cementing the intermediate casing on the 123HU well. Mr. Trejo stated the rig will resume drilling of the production string tomorrow. A hose discharging “flop water” into a WM container broke free and spilled what appeared to be ~10-15 gallons of mud/water mix onto the rig mats on containment. The spill was immediately vacuumed up and the area appeared remediated before I departed the site.

No puddles were observed on the pad surface. The E&S controls appeared dry. No fluid was observed in secondary containment. The chemical storage area was observed in the NW corner of containment. Mr. Tr

2750170 Primary Facility 2018-07-10 Drilling/Alteration No Violations Noted Drilling the 123 HU well at time of inspection.
2752408 Primary Facility 2018-07-16 Routine/Partial/Aerial Inspection No Violations Noted The DEP conducted a PARTIAL inspection of the Seneca Resources-DCNR 007 Pad K located in Delmar Twp, Tioga Co. on 7/16/2018 @1400 hours. The weather was 83 degrees, sunny, humidity 78%.

A Well site Restoration Extension Request(WSRER)was submitted on 6/26/2018. The filing requests a 24 month extension. The attached restoration plan shows a reduced pad size and the rain garden #7 infiltration basin. As of today's inspection, the pad size was observed at full size. The site is stabilized. Rain garden #7 was observed off the N side of the pad.

The onsite restoration drawings do not match the restoration drawings submitted with the WSRER. Please ensure only the most up-to-date plan drawings are located in the mailbox.

The WSRER is accepted at this time. I departed the site at 1445 hours.

2772504 Primary Facility 2018-08-28 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the DCNR 007 Pad K in Delmar Twp, Tioga County on 8/28/2018 at 1345 hours. The weather was clear, 74% humidity and 87 degrees.

Ellie Niles, DEP Water Quality Specialist, was onsite with me at the time of the inspection. The Patterson Rig#339 is currently onsite in the process of drilling the third of the six total wells. We spoke with Company man, Kevin Bradford, on the noted issues. We mentioned the torn containment in the chemical storage area, and the damp soil and puddles beneath the drill cuttings waste containers on the eastern side of the pad. He said the issues would be taken care of right away.

The following violations were cited against the ESCGP# ESX121170034(1): The waste containers on the eastern side of the pad not managed within secondary containment are considered in violation of Pa Code 25 Section 78a 64a(b)- All regulated substances including solid wastes must be managed within secondary containment on the well site and is cited at this time. Due

2779775 Primary Facility 2018-09-18 Follow-up Inspection No Violations Noted The DEP conducted a Follow-Up Inspection at the Seneca Resources - DCNR 007 Pad K located in Delmar Twp, Tioga Co. on 9/18/2018 @ 1330 hours. The weather was 74 degrees and sunny. Winds SW 6 mph humidity 65%.

Seneca is nearing completion of drilling of the 125 HU Utica well. Seneca only plans to drill 4 out of the 6 permitted wells while onsite.

During the previous inspection dated 8/28/2018, IR#2768464, waste containers holding drill cuttings were observed on the SE corner of the pad without secondary containment. Cuttings/fluid were observed dripping onto the pad surface. Puddles beneath the containers exhibited elevated field measured conductivity. Violations of the CSL 402(b), 25 Pa Code 78a.64a(b), and SWMA 301 were cited. As of today's inspection, all waste containers located on the SE corner of the pad are staged on secondary containment. All puddles, in the vicinity of the containers, exhibited conductivity <1000 uS/cm.

These violations are considered CORRECTED against the ESCGP at this time. We

2785886 Primary Facility 2018-10-09 Drilling/Alteration No Violations Noted Not inspected due to drilling 116HU well.
2803673 Primary Facility 2018-11-14 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the Seneca Resources DCNR 007 Pad K in Delmar TWP, Tioga County on 11/14/2018 at 1200 hours. Ellie Niles, DEP WQS, accompanied me for the inspection.

Adam Pierce was onsite an accompanied us around the site. He confirmed that only 4 wells were drilled, that the current frac was on the 125HU and that the wireline services were working on the 124HU. They started the frac on 11/11/18. They are bringing water from impoundment #1 through the above ground waterline for use on the frac. "Select" is the company monitoring water transfer.

We found a couple puddles in front of the frac tank containment on the east side of the pad with elevated conductivities. (Photos #4 & #5) This area is where trucks have been offloading fluid from the frac tanks. Adam Pierce had the onsite vac truck driver suck up the fluids as soon as possible. The areas after remediation are seen in photos #8 & #9.

Due to the conditions observed onsite during the course of the inspection, a violation o

2822452 Primary Facility 2019-01-04 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of Seneca Resource's DCNR 007 Pad K in Delmar Twp, Tioga County on 1/4/2019 at 1000 hours. I spoke with company man Andy and Guy Williams. Both of them accompanied me around the site.

Keane was currently working on the last stage of the 116HU frac. No more fresh water is being ran through the above ground waterline from the impoundment. After the frac is done (today) they will rig down and bring in another rig to drill out the plugs which plans on coming this Tuesday. The frac is moving to the DCNR 100M in Trout Run after this.

Site conditions looked overall good. A couple of the chemical storage secondary containments were packed down due to being driven over (see photo #2).It was mentioned that the equipment will be moved shortly due to rigging down and containment will be removed. Most fluids onsite were frozen. The area in front of the frac tank containment (was a mess last visit) is now straightened up and has containment laid down(see photo #3).

No issues or v

2856994 Primary Facility 2019-03-21 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection conducted a routine inspection of the Seneca Resources - DCNR 007 Pad K located in Delmar Twp, Tioga Co. on 3/21/2019 @1330 hours. The weather was 41 degrees, rain, winds SSE 6mph. Onsite activity consists of simultaneous operations involving a work-over rig performing a clean-out on the 124HU; the 123HU, 125HU, and the 116HU are flowing back; containment has been expanded in preparation of clean-out activities on the 73H well. Onsite for the inspection was Seneca representative Scott Digel, Completions Consultant.

No violations are noted at this time. I departed the site @1500 hours.

For data sources see[8]

References