X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21799

Well Details

Well ID: 37-117-21799
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Bloss Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 152881
Farm/Lease Name: DCNR 594 02 205 08 8H
License Status:
Spud Date: 2016-03-26
Permit Date: 2015-08-28
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.640050
Longitude: -77.113164

For data sources see[1][2][3]

Well History

Date Event
Deviated
2015-08-28 New Permit Application
2016-03-24 Performed Spud Operation
2016-05-24 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-09-03 2017-10-02 7,874 4,425,860 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Methanol 67-56-1 1 0.00000210
Ethylene glycol 107-21-1 5 0.00001080
Hydrochloric acid 7647-01-0 7.5 0.0141858 6532
Propargyl alcohol 107-19-7 10 0.00007403 35
Sodium phosphate, tribasic 7601-54-9 5 0.00001080
Methanol 67-56-1 60 0.000444153 205
Oxyalkylated Alcohol Proprietary 5 0.00003700
Crystalline silica, quartz 14808-60-7 100 19.6482 9,047,280.0
Modified thiourea polymer Proprietary 30 0.000222077 103
Distillate, petroleum, hydrotreated, light 64742-47-8 30 0.0002218
Inorganic Salt Proprietary 10 0.00007390
Fatty acids, tall oil Proprietary 30 0.000222077 103
Glutaraldehyde 111-30-8 30 0.00006220
Ethoxylated alcohols Proprietary 30 0.000222077 103
Amine Triphosphate Proprietary 30 0.00006480
Olefins Proprietary 5 0.00008883 44
Substituted Alkylamine Proprietary 1 0.00000740
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 80.1619 36,911,600.0
Frac Fluid Package TightROCK Solutions Frac Fluid Additives Listed Below
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.189144 87094
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 449,555.90 68 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 1,373,833.30 365 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 872,674.00 319 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 REPSOL OIL & GAS USA LLC Drill Cuttings 1,238.48 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR097R017
2016 REPSOL OIL & GAS USA LLC Synthetic Liner Materials 8.27 Tons LANDFILL 8-0728-0004/013
2016 REPSOL OIL & GAS USA LLC Drill Cuttings 19.62 Tons LANDFILL 8-0728-0004/013
2017 REPSOL OIL & GAS USA LLC Synthetic Liner Materials 17.20 Tons LANDFILL 8-0728-0004/013
2017 REPSOL OIL & GAS USA LLC Soil Contaminated by Oil & Gas Related Spills 0.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2017 REPSOL OIL & GAS USA LLC Produced Fluid 1,010.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 REPSOL OIL & GAS USA LLC Produced Fluid 10,577.56 Bbl REUSE (AT WELL PAD)
2017 REPSOL OIL & GAS USA LLC Soil Contaminated by Oil 0.03 Tons RESIDUAL WASTE TRANSFER FACILITY 101611
2017 REPSOL OIL & GAS USA LLC Produced Fluid 261.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 REPSOL OIL & GAS USA LLC Produced Fluid 4,980.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 REPSOL OIL & GAS USA LLC Produced Fluid 544.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 REPSOL OIL & GAS USA LLC Produced Fluid 8,187.98 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Synthetic Liner Materials 1.54 Tons LANDFILL 8-0728-0004/013
2018 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 43.55 Bbl REUSE (AT WELL PAD)
2018 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 112.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 REPSOL OIL & GAS USA LLC Synthetic Liner Materials 0.33 Tons LANDFILL 301358
2019 REPSOL OIL & GAS USA LLC Produced Fluid 1,274.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 REPSOL OIL & GAS USA LLC Produced Fluid 2,752.54 Bbl REUSE (AT WELL PAD)
2019 REPSOL OIL & GAS USA LLC Produced Fluid 119.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 REPSOL OIL & GAS USA LLC Produced Fluid 217.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2019 REPSOL OIL & GAS USA LLC Produced Fluid 59.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 REPSOL OIL & GAS USA LLC Other Oil & Gas Wastes 26.13 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2425315 Primary Facility 2015-11-16 Preoperation Inspection No Violations Noted Talisman still contructing this site. Includes 16 million gallon freshwater impoundment.
2480669 Primary Facility 2016-04-05 Drilling/Alteration No Violations Noted
2491306 Primary Facility 2016-06-08 Incident- Response to Accident or Event No Violations Noted Inspection conducted in response to spill of 20 gallons of diesel fuel reported by Talisman to DCNR (lessee). This has been assigned Spill Notification No. 320223 in the Department's Complaint Tracking System.

The spill occurred during fuel transfer operations near the drilling rig on site. The spill was to containment and not the ground surface; no spilled fuel left containment. The spill was promptly cleaned up, which included the removal of two deck mats and the vacuuming of fluids from the containment beneath that location. The containment was inspected and no holes or tears were identified.

During my inspection no additional areas of staining, diesel odors, or spilled fuel were identified elsewhere on the well site.

This inspection has been filed under Permit No. 117-21799.

No violations were cited during this inspection.

2519692 Primary Facility 2016-09-16 Routine/Partial Inspection No Violations Noted 4 Marcellus Shale wells drilled, and a 16 million gallon water impoundment
2630893 Primary Facility 2017-08-30 Routine/Complete Inspection No Violations Noted I met Shaun Smith of Repsol on location. Site is being prepped for frac; 480K Dyna-Tank was in place and had been filled. Secondary containment for the tank was complete, and most of the site-wide containment was in place and bermed. Shaun stated that they should be pressure testing by Saturday.
2631414 Primary Facility 2017-08-31 Drilling/Alteration No Violations Noted
2632407 Primary Facility 2017-09-05 Routine/Partial Inspection No Violations Noted I met with Company Man Sheridan Smith who expects Halliburton to be finished fracturing the 4 Marcellus wells in about 25 days.

The highest electrical conductivity reading I got from the pad surface with an Oakton PCSTestr 35 was 0.48 mS/cm. Fresh water is contained in an onsite impoundment.

2643412 Primary Facility 2017-10-03 Incident- Response to Accident or Event No Violations Noted I met with Glen Cerny (Ensign) on site, and he showed me the area of the pad where the diesel spill occurred 5 days ago (photo 4). We also discussed the bridge (photo 1). He said they will remove the liquid, then replace the bridge.

They plan to start drilling out plugs and flowing back the wells this week.

2649638 Primary Facility 2017-10-18 Routine/Complete Inspection No Violations Noted I met Tony Baker when I arrived on-site. Basic Well Services workover rig was on location, pulling tubing from the 4H well. Containments were in good condition; however, I noted on the east side of the pad, the liner was no longer running up onto the soil berm, but stopped short. Tony told me he would have it repaired. AST containment also appeared to be well maintained and sound.
2697193 Primary Facility 2018-02-22 Routine/Partial Inspection No Violations Noted Electrical conductivity readings taken with an Oakton PCSTestr 35. Water on the pad gave a 0.02 mS/cm reading. Air temp 33F. JLP

For data sources see[8]

References