37-117-21397

Well Details

Well ID: 37-117-21397
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Charleston Township
Operator Name: SWEPI LP
Well Pad ID: 147877
Farm/Lease Name: BURKE T 285S 5H
License Status: Plugged and Abandoned
Spud Date: 2011-12-24
Permit Date: 2011-12-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.781114
Longitude: -77.223703

For data sources see[1][2][3]

Well History

Date Event
2011-12-08 New Permit Application
2011-12-21 Performed Spud Operation
2011-12-24 Drilling Completion
2016-04-22 Begin Plugging
2016-04-22 Finished Plugging
2016-05-24 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0
2014 SWEPI LP 0.00 0 0.00 0 0.00 0
2015 SWEPI LP 0.00 0 0.00 0 0.00 0
2016 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2110013 Primary Facility 2012-10-22 Routine/Complete Inspection No Violations Noted
2406733 Primary Facility 2015-09-15 Routine/Complete Inspection No Violations Noted
2479669 Primary Facility 2016-04-25 Complaint Inspection No Violations Noted Complaint inspection. The 5H & 6H wells were being plugged at time of complaint. The 5H and 6H wells were spud on 12/8/11 (80' of conductor pipe installed), however never drilled. A stained area was noted on pad surface. Staining was grayish-brown in color. SWEPI stated that cellar water and surface water which had accumulated in the conductor pipe was discharged to pad surface to infiltrate. Staining on pad was surficial. Requested that SWEPI evaluate stained area and determine whether remedial actions are necessary. TLT
2496262 Primary Facility 2016-06-27 Routine/Complete Inspection No Violations Noted
2560970 Primary Facility 2017-02-10 Routine/Partial Inspection No Violations Noted Partial inspection. Site idle and snow covered. 1H - 4H have been partially drilled to depth of 2030' (according to Well Record Reports). The 5H & 6H wells were plugged in April 2016. The 1V well was placed on inactive status on 5/9/14. SWEPI's two-year restoration extension request was approved on 5/4/16. A new ESCGP2 application is currently under review. Permanent stablization and E&S controls were not observed due to the snow cover. No violations were cited during the inspection. TLT
2602760 Primary Facility 2017-06-06 Routine/Partial Inspection No Violations Noted Puddle on pad 0.18 mS/cm w an Oakton PCSTestr 35. Onsite ~1415-1510.

For data sources see[6]